Loading...
Ordinance 007-20161 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 ORDINANCE NO. 007 -2016 AN ORDINANCE BY THE MONROE COUNTY BOARD OF COUNTY COMMISSIONERS AMENDING THE MONROE COUNTY COMPREHENSIVE PLAN; ADOPTING THE 10 -YEAR WATER SUPPLY PLAN UPDATE TO BE CONSISTENT WITH THE SOUTH FLORIDA WATER MANAGEMENT DISTRICT LOWER EAST COAST WATER SUPPLY PLAN UPDATE OF 2013; PROVIDING FOR SEVERABILITY; PROVIDING FOR REPEAL OF CONFLICTING PROVISIONS; PROVIDING FOR TRANSMITTAL TO THE STATE LAND PLANNING AGENCY AND THE SECRETARY OF STATE; PROVIDING FOR INCLUSION IN THE MONROE COUNTY COMPREHENSIVE PLAN; PROVIDING FOR AN EFFECTIVE DATE. WHEREAS, Section 163.3180(2)(x). F.S. requires local governments to consult with water suppliers to ensure that adequate water supplies will be in place and available to serve new development no later than when the local government issues a certificate of occupancy. Local Governments should update their comprehensive plans and land development regulations to address this concurrency requirement; and WHEREAS, the Monroe County Comprehensive Plan and Land Development Code already have adopted policies and regulations requiring concurrency; and WHEREAS, pursuant to Section 163.3177(6)(c), F.S., local governments that are subject to a regional water supply plan must update their adopted 10 -year water supply facilities work plan within 18- months of the adoption of the regional water supply plan update; and WHEREAS, the South Florida Water Management District (SFWMD) updated its Lower East Coast Water Supply Plan on September 12, 2013, which identifies areas where water supply, demand, and shortages are projected to occur within the next 20 years; and WHEREAS, the service provider for potable water in Monroe County is the Florida Keys Aqueduct Authority (FKAA) and the FKAA has coordinated with Monroe County staff to ensure that the current potable water supply and projected demands are incorporated within the Monroe County 10 -year Water Supply Facilities Work Plan Update; and WHEREAS, the FKAA 20 -year Water System Capital Improvement Master Plan serves as the Monroe County water supply plan; and WHEREAS, the FKAA demand and supply data project adequate water supply; and File: 2014 -100 Page 1 of 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 WHEREAS, at a regularly scheduled meeting held on the 23` day of September, 2014, the Monroe County Development Review Committee considered the proposed amendment; and WHEREAS, at a regularly scheduled meeting held on the 28` day of January, 2015, the Monroe County Planning Commission held a public hearing for the purpose of considering the proposed amendment and recommended approval to the Board of County Commissioners, contingent on revisions to sections 2.2 and 3.9 of the 10 -year Water Supply Facilities Work Plan Update to reconcile conflicting information regarding potential saltwater intrusion into the FKAA wellfield due to sea level rise, memorialized by Resolution No. P02 -15; and WHEREAS, staff made revisions to sections 2.2 and 3.9 of the 10 -year Water Supply Facilities Work Plan Update, as requested by the Planning Commission; and WHEREAS, the Board of County Commissioners held a public hearing on the 15` day of July, 2015, for the purpose of considering the transmittal of the proposed amendment to the State Land Planning Agency for review and comment; and WHEREAS, the Board of County Commissioners voted to transmit the amendment and made the following Conclusions of Law: 1) the ordinance is consistent with the Principles for Guiding Development in the Florida Keys Area of Critical State Concern; 2) the ordinance is consistent with the provisions and intent of the Monroe County Comprehensive Plan; and 3) the ordinance is consistent with the provisions and intent of the Monroe County Code; and WHEREAS, on October 19, 2015, the State Land Planning Agency issued its Objections, Recommendations, and Comments (ORC) report, which identified two objections and two comments; and WHEREAS, the County must address the two identified objections and determine whether to adopt the amendment, adopt the amendment with changes or not adopt the amendment; and WHEREAS, the County is not required to make modifications relative to the two comments; and WHEREAS, the ORC report's first objection relates to Goals, Objectives, and Policies (GOPs) proposed under the County's Evaluation and Appraisal Review (EAR) that were not yet adopted; and WHEREAS, the ORC report's recommendation states: Remove the Goals, Objectives, and Policies referenced in Section 5.0 of the Water Supply Facilities Work Plan. Alternatively, include these policies within the Ordinance for explicit adoption and include them within their respective elements within the Comprehensive Plan. However, if the Evaluation and Appraisal Review -based amendments are adopted prior to this amendment's adoption, and includes these policies verbatim, they may remain within the Water Supply Facilities Work Plan; and File: 2014 -100 Page 2 of 4 I WHEREAS, the County's response to the first objection is that the GOPs referenced in 2 Section 5.0 of the Work Plan are included in the proposed EAR -based amendments to the 3 Comprehensive Plan, which are anticipated to be adopted at the April 13, 2016 special meeting 4 of the BOCC. Based on guidance received from the South Florida Water Management District 5 regarding preparation of the Work Plan, the relevant GOPs from the County's Comprehensive 6 Plan should be included in the Work Plan; and 7 8 WHEREAS, in response to DEO's first objection, staff is proposing to leave the GOPs 9 within the Work Plan, assuming they are adopted at the April 13, 2016 public hearing as part of 10 the EAR -based amendments to the Comprehensive Plan; and 11 12 WHEREAS, the referenced EAR -based amendments were adopted by the BOCC on 13 April 13, 2016; and 14 15 WHEREAS, the ORC report's second objection relates to Policies regarding a five year 16 timeframe for considering the vulnerability of public infrastructure to sea level rise; and 17 18 WHEREAS, the ORC report's recommendation states: Use the available data and 19 analysis to identify points along a sea level rise continuum that threaten public infrastructure. The 20 County can then identify approximate planning time frames for addressing those risks; and 21 22 WHEREAS, the County's response to the second objection is that the County does not 23 currently have data available regarding the elevations of water supply facilities; the data or 24 mapping capabilities to analyze the projected 3" to 7" rise; or a specific timeline of estimated 25 future sea level rise. Additional time is necessary to allow the county to obtain additional data on 26 both the water supply facilities and LIDAR or comparable elevation data. Further, the referenced 27 policies are proposed as part of the new Energy and Climate Element in the EAR -based 28 amendments to the Comprehensive Plan. These policies have been transmitted to the State, and 29 the County received DEO's ORC report on April 28, 2015, which identified no objections or 30 comments regarding the policies. They are anticipated to be adopted at the April 13, 2016 special 31 meeting of the BOCC as part of the proposed EAR -based amendments to the Comprehensive 32 Plan; and 33 34 WHEREAS, in response to the second objection in the ORC report, the County is 35 proposing to leave reference to Policies 1502.1.5, 1502.1.6 and 1502.1.7 within the Work Plan, 36 assuming they are adopted at the April 13, 2016 public hearing as part of the EAR -based 37 amendments to the Comprehensive Plan; and 38 39 WHEREAS, Policies 1502.1.5, 1502.1.6 and 1502.1.7 were adopted by the BOCC on 40 April 13, 2016, as part of the EAR -based amendments to the Comprehensive Plan; 41 42 NOW, THEREFORE, BE IT ORDAINED BY THE BOARD OF COUNTY 43 COMMISSIONERS OF MONROE COUNTY, FLORIDA: 44 45 Section 1. The Monroe County Comprehensive Plan is amended as follows (deletions are 46 striek thfough and additions are underlined File: 2014 -100 Page 3 of 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 BOARD OF COUNTY COMMISSIONERS : .f OF MONROE COIVNTY. FLORIDA BY: Mayor eat r arruthers N G? 4� 3 a 0 cr. - r rrn 0 0 71 tK MONROE COUNTY ATTORNEY AFOPftOVED 14S�1�0 FORM: STEVEN T. WILLIAMS ASSISTANT C UN � ATTORNEY Date - .�P�g� Policy 701.1.86 Monroe County adopts the Monroe County 10 -Year Water Supply Facilities Work Plan update, dated March, 2016, by reference, into the Comprehensive Plan. Monroe County shall update the 10 -year Water Supply Work Plan every 5 years or within 18 months after the governing board of the South Florida Water Management District approves an updated regional water supply plan. Section 2. The Monroe County 10 -Year Water Supply Facilities Work Plan update, adopted by reference into the Comprehensive Plan, is attached to this ordinance as Exhibit A. Section 3. Severability. If any section, subsection, sentence, clause, item, change, or provision of this ordinance is held invalid, the remainder of this ordinance shall not be affected by such validity. Section 4. Repeal of Inconsistent Provisions. All ordinances or parts of ordinances in conflict with this ordinance are hereby repealed to the extent of said conflict. Section 5. Transmittal. This ordinance shall be transmitted by the Planning and Environmental Resources Department to the State Land Planning Agency pursuant to Chapter 163 and 380, Florida Statutes. Section 6. Filing and Effective Date. This ordinance shall be filed in the Office of the Secretary of State of Florida, but shall not become effective until a notice is issued by the State Land Planning Agency or Administration Commission finding the amendment in compliance, and if challenged until such challenge is resolved pursuant to Chapter 120, F.S. PASSED AND ADOPTED by the Board of County Commissioners of Monroe County, Florida, at a special meeting held on the 13` day of April, 2016. Mayor Heather Carruthers Mayor pro tem George Neugent Commissioner Danny Kolhage Commissioner David Rice Commissioner Sylvia Murphy Yes Yes c) Yes Yes Yes oc� Page 4 of 4 File: 2014 -100 Exhibit A to Ord 007 -2016 MONROE COUNTY, FLORIDA 10 -YEAR WATER SUPPLY FACILITIES WORK PLAN UPDATE Prepared By: Monroe County Planning & Environmental Resources Department March, 2016 TABLE OF CONTENTS 1.0 INTRODUCTION 1.1 Statutory History 1.2 Statutory Requirements 2.0 BACKGROUND INFORMATION 2.1 Overview 2.2 Relevant Regional Issues 3.0 DATA AND ANALYSIS 3.1 Population Information 3.2 Maps of Current and Future Areas Served 3.3 Potable Water Level of Service Standard 3.4 Population and Potable Water Demand Projections by Each Local Government Utility 3.5 Water Supply Provided by Local Government 3.6 Water Supply Provided by Other Entities 3.7 Conservation 3.7.1 Countywide Issues 3.7.2 Local Government Specific Actions, Programs, Regulations, or Opportunities 3.8 Reuse 3.8.1 Regional and Countywide Issues 3.8.2 Local Government Specific Actions, Programs, Regulations, or Opportunities 4.0 CAPITAL IMPROVEMENTS 4.1 Work Plan Projects 4.2 Capital Improvements Element/Schedule 5.0 GOALS, OBJECTIVES AND POLICIES 6.0 REGIONAL ISSUES IDENTIFIED IN REGIONAL WATER SUPPLY PLANS 6.1 Lower East Coast Water Supply Plan Update, September 12, 2013 6.2 Integrating Climate Change & Water Supply Planning In Southeast Florida, Southeast Florida Regional Climate Change Compact, June 10, 2014 7.0 REFERENCES 8.0 EXHIBITS Exhibit A Section 7.2 of the Florida Keys Aqueduct Authority 20 -Year Water System Capital Improvement Master Plan, December 2006 1.0 INTRODUCTION The purpose of the Monroe County Water Supply Facilities Work Plan (Work Plan) is to identify and plan for the water supply sources and facilities needed to serve existing and new development within the local government's jurisdiction. Chapter 163, Part II, F.S., requires local governments to prepare and adopt Work Plans into their comprehensive plans within 18 months after the water management district approves a regional water supply plan or its update. The Lower East Coast Water Supply Plan Update was approved by the South Florida Water Management District (SFWMD) on September 12, 2013. Residents of Monroe County obtain their water directly from the Florida Keys Aqueduct Authority (FKAA), which is responsible for ensuring that enough capacity is available for existing and future customers. The Monroe County Water Supply Facilities Work Plan (Work Plan) will reference the initiatives already identified in FKAA's 20 -year Water System Capital Improvement Master Plan. According to state guidelines, the Work Plan and associated comprehensive plan amendments must address the development of traditional and alternative water supplies, bulk sales agreements and conservation and reuse programs that are necessary to serve existing and new development for at least a 10 -year planning period. The Monroe County Work Plan will have the same planning time schedule consistent with the comprehensive plan and the Lower East Coast Water Supply Plan Update, The County's Work Plan is divided into five sections: Section 1 — Introduction Section 2 — Background Information Section 3 — Data and Analysis Section 4 — Work Plan Projects /Capital Improvement Element/Schedule Section 5 — Goals, Objectives, Policies 1.1 Statutory History The Florida Legislature has enacted bills in the 2002, 2004, 2005, and 2011 sessions to address the state's water supply needs. These bills, particularly Senate Bills 360 and 444 (2005 legislative session), significantly changed Chapter 163 and 373 Florida Statutes (F.S.) by strengthening the statutory links between the regional water supply plans prepared by the water management districts and the comprehensive plans prepared by local governments. In addition, these bills established the basis for improving coordination between local land use planning and water supply planning. 1.2 Statutory Requirements Monroe County has considered the following statutory provisions when updating the Water Supply Facilities Work Plan (Work Plan): 1. Coordinate appropriate aspects of its comprehensive plan with the appropriate water management district's regional water supply plan, [163.3177(4)(x), F.S.] 2. Ensure that its future land use plan is based upon availability of adequate water supplies and public facilities and services [s.163.3177(6)(a), F.S. Data and analysis demonstrating that adequate water supplies and associated public facilities will be available to meet projected growth demands must accompany all proposed Future Land Use Map amendments submitted to the Department for review. 3. Ensure that adequate water supplies and facilities area available to serve new development no later than the date on which the local government anticipates issuing a certificate of occupancy and consult with the applicable water supplier prior to approving a building permit, to determine whether adequate water supplies will be available to serve the development by the anticipated issuance date of the certificate of occupancy [s. 163.3180(2)(a), F.S., effective July 1, 2005]. 4. For local governments subject to a regional water supply plan, revise the General Sanitary Sewer, Solid Waste, Drainage, Potable Water, and Natural Groundwater Aquifer Recharge Element (the "Infrastructure Element "), within 18 months after the water management district approves an updated regional water supply plan, to: a. Identify and incorporate the alternative water supply project(s) selected by the local government from projects identified in the updated Lower East Coast Regional Water Supply Plan, or the alternative project(s) proposed by the local government under s. 373.709(8)(b), F.S. [s. 163.3177(6)(c), F.S.]; b. Identify the traditional and alternative water supply projects and the conservation and reuse programs necessary to meet current and future water use demands within the Lower East Coast Regional Water Supply Plan [s. 163.3177(6)(c), F.S.]; and c. Update the Work Plan for at least a 10 -year planning period for constructing the public, private, and regional water supply facilities identified in the element as necessary to serve existing and new development. [s. 163.3177(6)(c), F.S.] 5. Revise the Five -Year Schedule of Capital Improvements to include any water supply, reuse, and conservation projects and programs to be implemented during the five -year period [s. 163.3177(3)(a)4, F.S.]. 6. To the extent necessary to maintain internal consistency after making changes described in Paragraph 1 through 5 above, revise the Conservation Element to assess projected water needs and sources for at least a 10 -year planning period, considering the Lower East Coast Regional Water Supply Plan, as well as applicable consumptive use permit(s). [s.163.3177 (6)(d), F.S.] The plan must address the water supply sources necessary to meet and achieve the existing and projected water use demand for established planning period, considering the appropriate regional water supply plan. [s.163.3167 (9), F.S.] 2 7. To the extent necessary to maintain internal consistency after making changes described in Paragraphs 1 through 5 above, revise the Intergovernmental Coordination Element to ensure coordination of the comprehensive plan with the Lower East Coast Regional Water Supply Plan. [s. 163.3177(6)(h) L, F.S.] 8. While an Evaluation and Appraisal Report is not required, local governments are encouraged to comprehensively evaluate, and, as necessary, update comprehensive plans to reflect changes in local conditions. The evaluation could address the extent to which the local government has implemented the need to update their Work Plan, including the development of alternative water supplies, and determine whether the identified alternative water supply projects, traditional water supply projects, bulk sales agreements, and conservation and reuse programs are meeting local water use demands. [s. 163.3191 (3) F.S.] 2.0 BACKGROUND INFORMATION 2.1 Overview Monroe County was incorporated in 1824, making it one of the first counties established in the State of Florida. Monroe County includes an approximately 112 -mile long string of islands served by Highway US 1, an area of approximately 1,200,344 acres bounded by the Atlantic Ocean to the east and south, the Gulf of Mexico and Florida Bay to the west, and Miami -Dade County to the north. Incorporated municipalities within Monroe County encompass 12,678 acres, which include Key West, Marathon, Key Colony Beach, Layton, and Islamorada. A non - contiguous uninhabited mainland portion of Monroe County totaling 944,275 acres is located within Everglades National Park with another 126,437 acres located within Big Cypress National Park. Fort Jefferson/Dry Tortugas National Parks total almost 64,379 acres. The remaining unincorporated area totals 51,747 acres or approximately 81 square miles. Monroe County has limited or restricted growth potential. Future development potential and population growth is limited by linear geography, the amount of land already in public ownership, and the scarcity of vacant and developable land, together with growth restrictions dictated by the County's Residential Rate of Growth Ordinance (ROGO) and Non - Residential Rate of Growth Ordinance (NROGO). These growth ordinances were developed following designation of the Florida Keys Area of Critical State Concern and the completion of the Florida Keys Carrying Capacity Study. The unincorporated County's total ROGO annual allocation for new residential building permits is 197 dwelling units per year, and the County allocates 47,083 square feet of new floor area for nonresidential uses. This provides the FKAA with a firm basis for predicting future water supply allocation needs. Existing land use data in the 2011 Technical Document of the Monroe County Comprehensive Plan reveals that 4,988 acres or 6.8% of the total gross acreage in the unincorporated County (outside the mainland portion) is dedicated to residential uses. The remaining gross acreages are allocated to nonresidential uses such as commercial (1.2 %); industrial (0.6 %); institutional (0.2 %); recreational (1.8 %); military (5.5 %); conservation (75.9 %); and vacant or undeveloped (3.2 %). The County does not anticipate substantial 3 increases in land area in the near future, unless there is policy decision from the municipalities for dissolution. In the meantime, the residential and nonresidential growth rate is anticipated to be minimal for the next 10 to 20 years due to ROGO and NROGO. 2.2 Relevant Regional Issues As the state agency responsible for water supply in the Lower East Coast planning area, the SFWMD plays a pivotal role in resource protection, through criteria used for Consumptive Use Permitting. As pressure increased on the Everglades ecosystem resource, the Governing Board initiated rule- making to limit increased allocations dependent on the Everglades system. As a result, the Regional Water Availability Rule was adopted by the Governing Board on February 15, 2007 as part of the SFWMD's water use permit program. This reduced reliance on the regional system for future water supply needs, and mandates the development of alternative water supplies and an increase in the use of conservation and reuse techniques. The regional issues identified for 2030 in the Lower East Coast Water Supply Plan Update (adopted September 12, 2013) include: 1. Increased withdrawals from both the Surficial Aquifer System (SAS) and surface water from Lake Okeechobee are limited; 2. Conservation continues to be relied upon to reduce per capita use and as a means to potentially delay or perhaps avoid adding capacity; 3. Use of reclaimed water continues to be an important alternative source in the region and helps to meet requirements of the 2008 Leah G. Schad Ocean Outfall Program; and 4. The FKAA wellfield in Florida City is indicated as a Utility at Risk from saltwater intrusion. The sole source provider of potable water to Monroe County is FKAA, whose wellfield is located in Florida City. As stated above, the Lower East Coast Water Supply Plan Update indicates the FKAA wellfield as a Utility at Risk relative to saltwater intrusion based on SFWMD's updated analysis of utilities facing saltwater intrusion in 2007 following an extended period of dry weather and concerns for accelerated saltwater intrusion. SFWMD anticipates reformulating its analysis of utilities at risk and utilities of concern prior to the next update of the LEC plan. This, along with the limited availability of SAS withdrawals, presents a potential risk to the water supply for all of Monroe County. FKAA is a permitted Floridan Aquifer User, which should offset any anticipated drought- driven salt water intrusion event. FKAA also operates reverse osmosis facilities in Marathon and Stock Island. Other regional water issues have been identified by the Southeast Florida Regional Climate Change Compact, which includes Palm Beach, Broward, Miami -Dade and Monroe Counties. The Compact communities have agreed to use a sea level rise prediction of between 3 and 7 inches by 2030, and between 9 and 24 inches by the year 2060 for planning purposes in the Southeast Florida region until more definitive information on future sea level rise is available (the Compact's A Unified Sea Level Rise Projection for Southeast Florida, April, 2011). The potential landward movement of the salt water intrusion line resulting from the impact of sea 4 level rise may affect future decisions regarding the implementation of capital improvements, requiring adaptation mitigation strategies to preserve the potable water supply. Monroe County's climate change and sustainability consultants have recently summarized hydrologic modeling by the United States Geological Survey that suggests relatively low risk to the FKAA wellfields in Florida City under even the worst -case 2060 sea level rise scenarios. However, FKAA continues to monitor the most current data and analysis regarding this issue. To address these issues, FKAA's strategic goals include encouragement of water conservation and reuse through their grant and rebate incentive programs for customers and continued development of their reclaimed water program. Additionally, as shown in Figure 30 of the Lower East Coast Water Supply Plan Update, FKAA is a permitted Floridan Aquifer User, which should offset any anticipated drought- driven salt water intrusion event. Further, FKAA also operates RO facilities in Marathon and Stock Island, with a combined supply capacity of 3 MGD, as an alternative water source for the county during emergencies and extreme peaks in demand. 3.0 DATA AND ANALYSIS 3.1 Population Information The County's existing and future population figures are derived from the projections prepared by Fishkind and Associates for the Monroe County 2030 Comprehensive Plan Update (March 15, 2011). The methodology for the preparation of these projections was approved by the Florida Department of Economic Opportunity (formerly known as the Department of Community Affairs (DCA). Table 9 of this report identifies unincorporated functional population (permanent and seasonal) projections from 2000 — 2030. In 2000, the unincorporated functional population was 69,277. This increased to 70,808 in 2010 and is projected to be 71,763 in 2015; 72,494 in 2020; 73,225 in 2025; and 73,956 in 2030, The projection reflects a total increase of 4,679 in population with a predicted decrease in permanent population and increase in seasonal population. The relatively minor increase in population growth is reflective of the fact that County development is substantially constrained, with future development potential and population growth limited by the amount of land in public ownership and the scarcity of vacant developable land, together with growth restrictions dictated by the County's Residential Rate of Growth Ordinance (ROGO) and Non - Residential Rate of Growth Ordinance (NROGO). These growth ordinances were developed following designation of the Florida Keys Area of State Critical Concern and the completion of the Florida Keys Carrying Capacity Study. The County's total ROGO annual allocation for new residential building permits is 197 dwelling units per year. This provides a firm basis for predicting future water supply allocation needs. 3.2 Maps of Current and Future Areas Served A map depicting current and future County boundaries served by the FKAA is included as Figure 1 on page 8 of this document. 5 3.3 Potable Water Level of Service (LOS) Standard Pursuant to the 2010 Comprehensive Plan, Monroe County has an adopted Potable Water LOS of 132 gallons /capita/day. The FKAA has recommended an overall LOS for Monroe County of 100 gallons /capita/day, and this adjustment has been included in the Monroe County 2030 Comprehensive Plan update (to be adopted in 2016). The unincorporated Monroe County 2015 Functional population projection was 71,763, therefore 7.2 MGD or more of water supply capacity is required to meet the adopted concurrency standard for residential potable water. In 2014, the overall Monroe County water consumption was 94 gal/capita/day (see Figure 3). Therefore the County is meeting the FKAA LOS of 100 gal/capita/day. 3.4 Population and Potable Water Demand Projections The population estimates and projections and the potable water demand projections for unincorporated Monroe County are presented below in Table 1. The projections are through the year 2030. The population projections are consistent with the other elements of the comprehensive plan. The water demands are for finished water. Table 1. Population & Potable Water Demand Projections Year 2010 2015 2020 2025 2030 Functional Population Projection* 70,080 71,763 72,494 73,225 73,956 Water Supply Demand (MGD) 7.0 7.2 7.2 7.3 7.4 Trunctionat ropuiation means total population: permanent plus seasonal residents. (Source: Table 9 - Monroe County 2010 -2030 Population Projections March 15, 2011, Keith and Schnars, P.A.; Fishkind and Associates) The FKAA Projected Finished Water Demand compares projected population and potable water demand for the entire FKAA service area. In summary, FKAA's average daily water demand for the entire service area is expected to increase from 16.22 MGD in 2010 to 17.76 MGD in 2015 and 21.48 MGD in 2030. 3.5 Water Supply Provided by Local Government Monroe County does not supply potable water to Unincorporated Monroe County and its municipalities. 3.6 Water Supply Provided by Other Entities The Florida Keys Aqueduct Authority (FKAA) is the sole provider of potable water in the Florida Keys, established by Special Legislation, Chapter 76 -441, L.O.F. (as amended). FKAA's primary water supply is the Biscayne Aquifer, a shallow groundwater source. The FKAA's wellfield is located within an environmentally protected pine rockland forest west of Florida City. The location of the wellfield near Everglades National Park, along with restrictions enforced by state and local regulatory agencies, contributes to the unusually high water quality. These wells contain some of the highest quality groundwater in the state, meeting all regulatory standards prior to treatment. Additionally, the FKAA is continually monitoring, assessing, and working to eliminate potential hazards to our water source, including inappropriate aquifer utilization, unsuitable land uses, and the potential for saltwater intrusion. The groundwater from the wellfield is treated at the FKAA's Water Treatment Facility in Florida City, which currently has a maximum water treatment design capacity of 29.8 million gallons per day (MGD). The primary water treatment process is a conventional lime softening /filtration water treatment plant and is capable of treating up to 23.8 MGD from the Biscayne Aquifer. The secondary water treatment process is the newly constructed reverse osmosis (RO) water treatment plant which is capable of producing 6 MGD from the brackish Floridan Aquifer. The product water from these treatment processes is then disinfected and fluoridated. The FKAA treated water is pumped 130 miles from Florida City to Key West supplying water to the entire Florida Keys. The FKAA maintains storage tank facilities which provide an overall storage capacity of 45.2 million gallons system wide. The sizes of tanks vary from 0.2 to 5.0 million gallons. These tanks are utilized during periods of peak water demand and serve as an emergency water supply. Since the existing transmission line serves the entire Florida Keys (including Key West), and storage capacity is an integral part of the system, the capacity of the entire system must be considered together, rather than in separate service districts. Additionally, two saltwater RO plants, located on Stock Island and Marathon, are available to produce potable water under emergency conditions. The RO desalination plants have design capacities of 2.0 and 1.0 MGD, respectively. At present, Key West and Ocean Reef are the only areas of the County served by a flow of potable water sufficient to fight fires. Outside of Key West, firefighters rely on a variety of water sources, including tankers, swimming pools, and salt water either from drafting sites on the open water or from specially constructed fire wells. Although sufficient flow to fight fires is not guaranteed, new hydrants are being installed as water lines are replaced to make water available for fire - fighting purposes, and pump station/tank facilities are being upgraded to provide additional fire flow and pressure. A map of the key FKAA transmission and distribution facilities is shown in Figure I on the following page. The remainder of this page left intentionally blank. 7 Figure 1. FKAA Transmission & Distribution System Overview FLORIDA KEYS AQUEDUCT AUTHORITY TRANSMISSION & DISTRIBUTION SYSTEM OVERVIEW 45.2 MG STORAGE CAPACITY 1 YC 1 YS 1. KEY WEST 2 230 NP PUMPS ORIRIBIIiIdI 3110 STATION Stl.NMI 3 MD 2. STOCK ISLAND 1 {BS NP PUMP 2 30D w PUMPS s MO RAMROD KEY ��TT ATKRI 1 IOpp Np PUMP I 6. BIG PINE KEY 1 {00 NP PUMP I I 273 MP PUMPS 1 B 5. SUMMERUND KEY 2 30 M PUMPS N 1 . IIOD �J R PW/T r 4. BIG COPPITT KEY I MARATHON v BAY POINT 1- MS WW TREATMENT PUNT 2,0 MW R.O. PUNT STOCK ISLAND 0 sTS mat ztATKw 3. STOCK ISLAND (DESAL) 3 MD 1 A NP IR'T PUMP : 1x3 w PUMPS LITTLE VENICE M U � p TREATMENT PUNT a0 NDD WW TREATMENT PUNT -7. MARATHON -a. 69th ST MARATHON 3 x >D NP PUMPS STATNRI 2 300 o NP PUMPS 1 {00 NP PUMPS TRANMISSION BACKPUMPING CAPABILITIES MARATHON (1) -5 MG TANK STOCK ISLAND (3) -5 MG TANKS STOCK ISLAND DESAL (1) -5 MG TANK Demand for Potable Water Figures 2 and 3 provide a historical overview of the water demands in the FKAA service area including Water Use Permit (WUP) allocation limits, yearly percent changes, and remaining water allocations. In March 2008, South Florida Water Management District (SFWMD) approved the FKAA's modification of WUP 13- 00005 -5 -W for a 20 -year allocation from the Biscayne and Floridan Aquifers. This modified WUP provides an annual allocation of 8,751 Million Gallons (MG) or 23.98 MGD and a maximum monthly allocation of 809 MG with a limited annual withdrawal from the Biscayne Aquifer of 6,492 MG or 17.79 MGD and an average dry season (December 1 -April 30 of 17.0 MGD. In order to meet the requirements of this limitation, the FKAA constructed a new Floridan Aquifer Reverse Osmosis (RO) water treatment system. This RO water treatment system is designed to withdraw brackish water from the Floridan Aquifer, an alternative water source approximately 1,000 feet below the ground surface, and treat the water to drinking water standards. The RO water treatment plant provides added capability to limit Biscayne aquifer withdrawals and is designed to meet current and future water demands. The RO water treatment system provides an additional 6.0 MGD of potable water. 8 KEY LARGO s MD 15. FLORIDA CITY 6 3lATgN 1 Z 40 NP PUMPS s 1 14. OCEAN REEF- 21A MW 1111E SOFTENMO TIEATWIENT RANT 2 73 H ' PUMPS { NOD R.0. TREATMENT PLANT TAVERNIER J x 300 NP PUMPS 7 BW NP PUMPS PUM 13. ROCK HARBOR 7 1000 M DIESCL PUMPS E93KNENC7 BACKUP 1 LITTLE VENICE M U � p TREATMENT PUNT a0 NDD WW TREATMENT PUNT -7. MARATHON -a. 69th ST MARATHON 3 x >D NP PUMPS STATNRI 2 300 o NP PUMPS 1 {00 NP PUMPS TRANMISSION BACKPUMPING CAPABILITIES MARATHON (1) -5 MG TANK STOCK ISLAND (3) -5 MG TANKS STOCK ISLAND DESAL (1) -5 MG TANK Demand for Potable Water Figures 2 and 3 provide a historical overview of the water demands in the FKAA service area including Water Use Permit (WUP) allocation limits, yearly percent changes, and remaining water allocations. In March 2008, South Florida Water Management District (SFWMD) approved the FKAA's modification of WUP 13- 00005 -5 -W for a 20 -year allocation from the Biscayne and Floridan Aquifers. This modified WUP provides an annual allocation of 8,751 Million Gallons (MG) or 23.98 MGD and a maximum monthly allocation of 809 MG with a limited annual withdrawal from the Biscayne Aquifer of 6,492 MG or 17.79 MGD and an average dry season (December 1 -April 30 of 17.0 MGD. In order to meet the requirements of this limitation, the FKAA constructed a new Floridan Aquifer Reverse Osmosis (RO) water treatment system. This RO water treatment system is designed to withdraw brackish water from the Floridan Aquifer, an alternative water source approximately 1,000 feet below the ground surface, and treat the water to drinking water standards. The RO water treatment plant provides added capability to limit Biscayne aquifer withdrawals and is designed to meet current and future water demands. The RO water treatment system provides an additional 6.0 MGD of potable water. 8 KEY LARGO — MARATHON 6 3lATgN 1 130 NP PUMP Z 40 NP PUMPS L�L 3 700 NP PUMPS I. VACA ® 12. TAVERNIER J r 273NP 230M I PUMPS 5 5 PUM 13. ROCK HARBOR 10. CRAWL KEYtN 1 30 MP PUMP 2 30 NP PUMPS DUCK KEY 190 MD 11. ISLAMORADA Y WW TREATMENT PUNT 2 73 HP PUMP 69 KEY . NUMP I � LONG j l {00 MP PUIR LITTLE VENICE M U � p TREATMENT PUNT a0 NDD WW TREATMENT PUNT -7. MARATHON -a. 69th ST MARATHON 3 x >D NP PUMPS STATNRI 2 300 o NP PUMPS 1 {00 NP PUMPS TRANMISSION BACKPUMPING CAPABILITIES MARATHON (1) -5 MG TANK STOCK ISLAND (3) -5 MG TANKS STOCK ISLAND DESAL (1) -5 MG TANK Demand for Potable Water Figures 2 and 3 provide a historical overview of the water demands in the FKAA service area including Water Use Permit (WUP) allocation limits, yearly percent changes, and remaining water allocations. In March 2008, South Florida Water Management District (SFWMD) approved the FKAA's modification of WUP 13- 00005 -5 -W for a 20 -year allocation from the Biscayne and Floridan Aquifers. This modified WUP provides an annual allocation of 8,751 Million Gallons (MG) or 23.98 MGD and a maximum monthly allocation of 809 MG with a limited annual withdrawal from the Biscayne Aquifer of 6,492 MG or 17.79 MGD and an average dry season (December 1 -April 30 of 17.0 MGD. In order to meet the requirements of this limitation, the FKAA constructed a new Floridan Aquifer Reverse Osmosis (RO) water treatment system. This RO water treatment system is designed to withdraw brackish water from the Floridan Aquifer, an alternative water source approximately 1,000 feet below the ground surface, and treat the water to drinking water standards. The RO water treatment plant provides added capability to limit Biscayne aquifer withdrawals and is designed to meet current and future water demands. The RO water treatment system provides an additional 6.0 MGD of potable water. 8 Along with the new reverse osmosis water treatment plant, compliance with withdrawal limits can also be accomplished by using other alternative water sources (blending of the Floridan Aquifer, reclaimed water and operation of the RO desalination plants), pressure reduction, public outreach, and assistance from municipal agencies in enforcing water conservation ordinances. Figure 2 - Annual Water Withdrawals Year annual Withdrawal % Change WUP Limit (MG) (MG) Ak WUP +/- Annual Allocation (MG) 2002 6,191 10.03% 7,274 1083 2003 6,288 1.57% 7,274 986 2004 6,383 2.74% 7,274 813 2005 6,477 0.16% 7,274 803 2006 6,283 - 2.49% 7,274 964 2007 5,850 - 7.35% 7,274 1428 2008 5,960 1.89% 8,751 2791 2009 5,966 0.09% 8,751 2785 2010 5,919 -0.79% 8,751 2832 2011 6,327 6.89% 8,751 2424 2012 6,042 - 4.50% 8,751 2709 2013 6105 1.04% 8,751 2646 2014 6377 4.46% 8,751 2374 Source: Florida Keys Aqueduct Authority, 2015 Figure 3. M Potable Water Demand Summary FLORIDA KEYS AQUEDUCT AUTHORIT Potable Water Demand Summary - New Water Deman Actual Water Demand, and Expected Water Demand _Year - 2014 Year - 2014 Year 2015 New Water Actual Water Metered Water Expected Water Demand - Service - Gallons /Year Demand _ Gallons/Year Municipality Gallons/Year I Gallons/Yeare Unincorporated Monroe County 15,679,200 1,903,099,800 2,479,9 31,978 2,495,611,178 City of Key West — 3,631,200 1,766,546,300 2 ! 301.988,924 2,305,620,124 City of Marathon 8,314,800 495,760,700 95,524,800 646,028 453 124,478,4991 854,341,253 city of Key Colon 0 124,478,4 City of Layton 0 10,950,400 14,269,4811 14 269,481 7,273,200 622,144,200 4,894,026,200 8 107716 ,966 6,377,412,301 8,751,000,000 817,99 0,166 6,41 2,310,701 8,751,000,000 City of Islamorada Entire Florida Keys 34,898,400 SFWMD WUP Annual Allocation 'metered + unmetered water demand (is. flushing, )eaks, ate.) 9 • Figure 4 illustrates projected water supply availability vs projected water demand. Demand for potable water is influenced by many factors, including the number of permanent residents, seasonal populations and day visitors, the demand for commercial water use, landscaping practices, conservation measures, and the weather. Figure 4. FKAA Water Supply Available vs. Water Demand Projections FLORIDA KEYS AQUEDUCT AUTHORITY Water Supply Available vs. Water Demand Projections 30 25 — 20 Floridan Blend and Bypass(mgd) min Proposed Reclaimed Water 15M=Reverse-Osmosis WTP(mgd) c NM Biscayne Aquifer(mgd) c Adjusted 2014 Avg.Day Projections i o 10 — t 2005 Avg Day Projections thru 2026 5 0 • T r ` . n 00 rn -o . N m v .n I n ao m o .-+ N m v .n 50 N CO rn 0 O O 0 O .--( .--1 .--1 N N N N N N N N (0 O O O 0 O 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N N N N N N N N N N N N N N N N N N N N N N N N N As shown in Figure 5 on the following page,_the FKAA distributed an annual average of—from the Biscayne Aquifer from Floridan RO Production. This table also provides the water treatment capacities of the emergency RO plants. Since the emergency RO plants utilize seawater, a WUP is not required for these facilities. r ons indicate a slight increase in annual average daily demand rom . ' to 17.76 MG and an increase in maximum monthly demand from D to 596.29 MG. 10 Figure 5 - Projected Water Demand in (in MG) FKAA Permit 2014 Water Thresholds Demand 2015 Water Demand Projected Annual Allocation Average Daily Demand 23.98 17.47 17.76 Maximum Monthly Demand 809.01 546.94 596.29 Annual Demand 8,751 6,377 6,481 Biscayne Aquifer Annual Allocation/Limitations 154,495 17,228,192 112 Average Daily Demand 17.79 16.83 17.11 Average Dry Season Demand* 17.00 16.67 16.85 Annual Demand 6,492 6,143 6,245 Floridan RO Production 155,440 16,017,315 103 Average Daily Demand 6.00 0.64 0.65 Emergency RO WTP Facilities 155,441 16,345,205 105 Kermit L. Lewin Design Capacity 2.00 (MGD) 0.00 (MGY) 0.00 Marathon RO Design Capacity 1.00 (MGD) 0.00 (MGY) 0.00 AlIfigures are in millions of allons 156,391 16,508,197 106 *Dry Season is defined as December thru April 156,727 16,836,164 107 Source: Florida Keys Aqueduct Authority, 2015 Figure 6 provides the amount of water used on a per capita basis. Based on Functional Population and average dail demand, the average water consumption a k allons (person), which reflects the entire FKAA service area, including unincorporated Monroe County, Key West, Marathon, Islamorada, Key Colony Beach, and Layton. Figure 6. Per Capita Water Use (Entire FKAA Service Area) Functional Daily Average Per Capita Water Year _ Population' Demand (gallons) Consumption (gallons) 2000 153,080 17,016,393 111 2001 153,552 15,415,616 100 2002 154,023 16,962,082 110 2003 154,495 17,228,192 112 2004 154,924 17,652,596 114 2005 156,150 17,730,000 114 2006 155,738 17,287,671 111 2007 155,440 16,017,315 103 2008 154,728 16,285,383 105 2009 155,441 16,345,205 105 2010 155,288 16,210,959 104 2011 156,054 17,334,247 111 2012 156,391 16,508,197 106 2013 156,727 16,836,164 107 Source: 1. Monroe County Population Projections - Monroe County Planning Department, 2011 2. Florida Keys Aqueduct Authority, 2015 11 Improvements to Potable Water Facilities FKAA has a 20 -year Water System Capital Improvement Master Plan for water supply, water treatment, transmission mains and booster pump stations, distribution mains, facilities and structures, information technology, reclaimed water systems, and Navy water systems. In 1989, FKAA embarked on the Distribution System Upgrade Program to replace approximately 190 miles of galvanized lines throughout the Keys. FKAA continues to replace and upgrade its distribution system throughout the Florida Keys and the schedule for these upgrades is reflected in their long -range capital improvement plan. The FKAA's Water Distribution System Upgrade Plan included the upgrade or replacement of approximately 58,000 feet of water main during fiscal year 2014. The master plan was revised in 2013 to include the critical projects, as summarized in Figure 7. Figure 7 also provides the schedule and costs projected for the capital improvements to the potable /alternative water systems planned by the FKAA. The total cost of the scheduled improvements is approximately $34 million over the next 5 years. These projects are to be funded by the water rate structure, long -term bank loans, and grants. Figure 7 - FKAA Projected 5 Year Capital Improvement Plan 2014 2015 2016 2017 2018 Total Water Supply $0 $0 $1,000,000 $1,000,000 $0 $2 Water Treatment $0 $0 $2,600,000 $2,600,000 $0 $5,200,000 Transmission Mains & $200,000 $500,000 $500,000 $500,000 $1,250,000 $2,950,000 Booster Pump Stations Distribution Mains $4,300,000 $3,700,000 $2,250,000 $7,700,000 $3,600,000 $21,550,000 Facilities & Structures $0 $0 $100,000 $500,000 $0 $600,000 Information $0 $0 $0 $0 $0 $0 Technolo Reclaimed Water $0 $0 $0 $0 $0 $0 Systems Navy Water Systems $500,000 $400,000 $510,000 $585,000 $100,000 $2.095,000 Totals $5,000,000 $4,600,000 $6,960,000 $12,885,000 $4,950,000 $34,395,000 Source: Florida Keys Aqueduct Authority, 2013 In summary, based on current conditions and projects, an adequate supply of water to meet current and future demands is provided by the following: The Biscayne permitted water supply of 17.79 MGD, the 6.0 MGD RO water treatment plant, the new reclaimed water systems, and the ability to operate the 3.0 MGD RO desalination plants during emergency situations. The FKAA continues to monitor and track conditions and events that could negatively impact the existing water supply. Any such impacts will be evaluated to determine future changes necessary to continue servicing Monroe County with adequate water supply. 3.7 Conservation One method of reducing water use and increasing the availability potable water is the implementation of Best Management Practices for water use. Mandatory outdoor water 12 restrictions, water rate pricing and xeriscape landscaping that utilizes native flora can all assist in reducing potable water demand and the impacts of future growth. 3.7.1 County -Wide Issues Water conservation is one method available to promote the reduction of use and increase of availability of potable water. FKAA implements a high base water rate for water use, which effectively deters wasteful water use. Implementation of mandatory year -round watering restrictions also aid in conserving water. 3.7.2 Local Government Specific Actions, Programs, Regulations, or Opportunities Monroe County will coordinate future water conservation efforts with the FKAA and the SFWMD to ensure that proper techniques are applied. In addition, the County will continue to support and existing goals, objectives and policies in the comprehensive plan that promote water conservation in a cost - effective and environmentally sound manner. The County will also continue to actively support the SFWMD and FKAA in the implementation of new regulations or programs that are structured to conserve water during the dry season. Monroe County has also adopted an Interlocal Agreement between FKAA and Monroe County that will ensure the availability of potable water prior to the issuance of a building permit. This agreement is to be referenced in the Goals, Objectives and Policies of the Monroe County 2030 Comprehensive Plan Update as Policy 1301.1.16, which states: sh establishes a mechanism whereby the FKAA and the County identify the availability of water supply needed to serve existing and new development within the Unincorporated Area, monitor the utilization of water supply, and implement such alternative water su projects, traditional water supply projects, conservation ary to meet Monroe County's water supply needs. 3.8 Reuse Water reuse is a method for supplementing water availability. Desalination at the source through reverse osmosis is presently incorporated within the design of new water treatment facilities that tap into the Floridan Aquifer. Some local communities, such as Key Colony Beach, use recycled water to irrigate its municipal golf course. However, the cost of developing a centralized collection, treatment, and distribution system for recycled water in a county such as Monroe that is less than 5 miles wide and 112 miles long creates significant feasibility challenges. Monroe County, together with FKAA and the Key Largo Sanitary Sewer District, has implemented a public infrastructure program to construct and operate central sewer collection and treatment systems. Sewage treatment facilities will have the capability to make available gray water for non - potable water applications, such as irrigation for County parks and landscaped rights -of -way. However, the lack of possible users has inhibited the necessary investment to create and maintain a viable reuse water distribution system. 13 3.8.1 Regional and County -wide Issues State law supports reuse efforts. For the past years, Florida's utilities, local governments, and water management districts have led the nation in implementing water reuse programs that increase the quantity of reclaimed water used and public acceptance of reuse programs. Section 373.250(l) F.S. provides that "water reuse programs designed and operated in compliance with Florida's rules governing reuse are deemed protective of public health and environmental quality." In addition, Section 403.064(1), F.S., provides that, "reuse is a critical component of meeting the State's existing and future water supply needs while sustaining natural systems." 3.8.2 Local Government Specific Actions, Programs, Regulations, or Opportunities The County will support the SFWMD and FKAA water reuse projects and implementation of new regulations or programs designed to increase the volume of reclaimed water used and public acceptance of reclaimed water. The County has established regulations limiting the clearing of native habitat and requiring landscaping consisting of native plants, which are more drought tolerant and demand less irrigation than most non - native species. Incentives for the installation of cistern rain collection systems are also encouraged, such as the granting of positive points in the Rate of Growth Ordinance permit allocation system. 3.9 Climate Change and Sea Level Rise Southeast Florida is widely considered one of the most vulnerable regions to the impacts of climate change and sea level rise. This is especially true of the Florida Keys, a 110 mile string of offshore islands connected by US 1 to Miami -Dade County. As discussed earlier, potential landward movement of the salt water intrusion line resulting from the impact of sea level rise may affect future decisions regarding the implementation of capital improvements, requiring adaptation mitigation strategies to preserve the potable water supply. Monroe County's climate change and sustainability consultants have recently summarized hydrologic modeling by the United States Geological Survey that suggests relatively low risk to the FKAA wellfields in Florida City under even the worst -case 2060 sea level rise scenarios. However, FKAA continues to monitor the most current data and analysis regarding this issue. 3.10 Local Government Specific Actions, Programs, Regulations, or Opportunities FKAA presently operates two reverse osmosis (RO) plants within Monroe County, in Marathon and Stock Island, which have a combined production capacity of 3 MGD. A Floridan wellfield and RO water treatment facility were constructed by FKAA in Florida City and have been operational since the fall of 2009. This RO water treatment plant treats the brackish water of the Floridan Aquifer and has a production capacity of 6 MGD. Storage facilities maintained by the FKAA have a total storage capacity of 45.2 MG; of this amount, there is 12 MG of storage available in above ground storage reservoirs at Florida City. The remaining capacity is obtained from tanks located throughout the transmission and distribution system that provide an additional 33.2 MG of storage capacity. It is therefore 14 anticipated that FKAA will be well positioned to accommodate Monroe County's future water demands as sea level rise impacts South Florida's regional water supply. 4.0 CAPITAL IMPROVEMENTS 4.1 Work Plan Projects The FKAA 20 -Year Water System Capital Improvement Master Plan identifies all proposed work projects within Monroe County (See Exhibit A: Section 7.2 of the master plan). 4.2 Capital Improvements Element/Schedule Monroe County presently has a proposed LOS of 100 gallons /capita/day (2030 Comprehensive Plan Update). The County will continue to work with FKAA to ensure that the adopted LOS is maintained. Adoption by reference of Section 7.2 of the FKAA 20 -Year Water System Capital Improvement Master Plan (see Exhibit A) will link water availability and programmed improvements with the County's Concurrency Management System through the establishment of a permit review and approval process that requires evidence of water supply availability prior to the issuance of a building permit and certificate of occupancy. Exhibit 7 -2 of the FKAA 20 -Year Water System Capital Improvement Master Plan will serve as Monroe County's 10 -year Water Supply Plan and CIE for potable water (see Exhibit A). 5.0 GOALS, OBJECTIVES AND POLICIES The adopted and presently effective Monroe County Year 2010 Comprehensive Plan includes several Goals, Objectives and Policies (GOPs) that implement water supply concurrency and conservation. These GOPs are located within the Potable Water Element, Intergovernmental Coordination Element, Conservation and Coastal Management Element, Future Land Use Element and Capital Improvements Element. The following proposed amendments have been included in the Monroe County 2030 Comprehensive Plan, which the BOCC approved for transmittal to the State of Florida Department of Economic Opportunity (DEO) at their January 14, 2015 special meeting. On April 28, 2015, DEO issued its Objections, Recommendations, and Comments Report (ORC) on the ro osed amendments. The ORC contained no objections to the proposed changes below. 30 5.1 Potable Water Element GOAL 701 Monroe County shall support FKAA in the fulfillment of their statutory obligation and authority to provide for a safe, high quality and adequate supply, treatment, distribution, and 15 conservation of potable water to meet the needs of present and future residents. f9J- 5.011( Obiective 701.1 Monroe County shall ensure that at the time a nit-certificate of occupancy or its functional equivalent is issued, adequate potable water supply, treatment, and distribution facilities are available to support the development at the adopted level of service standards °nt • ,:t1, th e impaets o f s u """ rnr 5 [§ 163.3177(6)(c), F.S.,I Policy 701.1.1 Monroe County hereby adopts the following level of service standards to achieve Objective 701.1 and shall use these standards as the basis for determining facility capacity and the demand generated by a development. ror c n1 1(2)( f § 163.3180(1)(b)., F.S., §163.3180(2)., F.S., §163.3177(3)(a)3., F.S.] Level of Service Standards 1. Quantity: 100 gal. /capita/day* *Note: Based on historical data through December 2011; provided by FKAA, December 2012. Residential LOS 66.50 gal./eapita/day Nen Residential LOS 0.35 gal./sq. ft./day Over-all L - - 132 (n..,1 021 2009) „ q B �,-«ent��identia T n t 149 gallons ns day (2.24 aver-age per-sons pe-r- 2. Minimum Pressure: 20 PSI at customer service 3. Minimum Potable Water Quality: Shall be as defined by (Paft 143 National Seeendafy Drinking Standards, 40 GFR 143, 44F 4-21 8)Cha2ter 62 -550 F.A.C. 16 Polic 701.1.32 Monroe County shall adopt Land Developm Regulatiens land development regulations which provide a Concurrency Management System (See Capital Improvements Policy 1401.4.5). The Concurrency Management System shall ensure that no pefwAts certificate of occupancy or its functional equivalent will be issued for new development unless adequate potable water supply, treatment, and distribution facilities needed to support the development at the adopted level of service standards are available dent. [9i 5 > iwc-M L§ 163.3180(1)(b)., F.S., § 163.3180(2)., F.S., § 163.3177(3)(a)3., F.S., § 163.3177(6)(c)., F.S.I 701.1 - shall specify procedures for updating facility demand and capacity information, utilizing data provided by the FKAA as potable water facilities are installed or upgraded. f91 c n„ (2)(0 f§ 163.3180(2)., F.S.I Policy 701.1.64 Monroe County shall implement a concurrency management system that is consistent with the South Florida Water Management District Lower East Coast Regional Water Supply Plan and Florida Keys Aqueduct Authority 20- year Water System Capital Improvement Master Plan. (Ord. 022 -2009) Policy 701.1.75 Monroe County shall prepare and maintain a 10 -year Water Supply Work Plan that identifies alternative water supply projects, traditional water supply projects, conservation, and reuse necessary to meet the Monroe County Unincorporated Area water supply needs, consistent with the South Florida Water Management District Lower East Coast Regional Water Supply Plan and the Florida Keys Aqueduct Authority 20 -year Water System Capital Improvement Master Plan. (Ord. 022 -2009) [§ 163.3177(6)(c)3., F.S. l Policy 701.1.86 Monroe County shall update the 10 -year Water Supply Work Plan every 5 years or within 18 months after the governing board of the South Florida Water Management District approves an updated regional water supply plan. (Ord. 022 -2009) [§ 163.3177(6)(c)3., F.S.I 17 � 1 identi€� responsible paAies and aseiisic nd • • IN r F1SlLlITi iii M_ . . eff:,.:o..,,., ,.f r ............. * of u .. ides seFV.*-- L MY, I "Ol - developed areaslaeking • . identi€� responsible paAies and aseiisic nd • • IN r F1SlLlITi iii M_ . . eff:,.:o..,,., ,.f r €a * of u .. ides seFV.*-- events of: "Ol ienteasrs, developed areaslaeking full seFv . •. • ~11 '- • • um Level One Whether- the- pfe�eet is- eensijtent with thFKAA's -°no Level Two Whether th o r : ee l t o t te r „1�1;,. he a s for d Level -- — .. .- Whether ---- r~v.�- - -_ -� -. .._�...�... .., �1 VLVVL ru V11V 11V 0.1111 uilcs ,:.lo f.,,.;l;r;o� -m- -1 so r!. .. L,:o.,o full us e Yiv ...... l..vlla uaau .,vi i'ivvu, vl o o u ° f., a;r;o rcccrrrczcr. Level ThFee- �Whet#ef the eff:,.:o..,,., ,.f r €a * of u .. ides seFV.*-- events of: FeElueesfrto . ienteasrs, developed areaslaeking full seFv . 18 Obiective 701.22 Monroe County and FKAA shall work cooperatively with the FKAA, South Florida Water Management District ( SFWMD), Miami - Dade County, and the Cities of Layton, Key Colony Beach -ate, Marathon, Key West and the Village of Islamorada to ensure the protection and availability of an adequate raw water supply at the Florida City Wellfield to meet the needs of Monroe County through the year 204.30. f § 163.3177(6)(h)1., F.S.I Policy 701.22.1 Monroe County -,4ke- shall work closely with FKAA shall, as neeessay-y, in their renewal of the Florida City Wellfield consumptive use permit issued by SFWMD. Alter-native Policy 701.2.2 Monroe County shall encourage the use of alternative water sources such as reverse osmosis, cisterns and water re -use and -shall devaluate the feasibility of using such alternative sources d and the fnest feasible solution dented -in the event that the necessary withdrawals from the Biscayne Aquifer are limited. ; Policy 701.22.23 QN Monroe County GFewth Management Division shall provide teehnieal assistanee shall coordinate with the FKAA for the consumptive use permitting process. This teeMieal assistaneecoordination shall include providing information regarding future land use growth patterns, population trends, growth management policies and demand projections to ensure consistency between the FKAA permitting process and the Monroe County Comprehensive Plan. ro �T( 2 )(e)' • 9i 5 . 01 3(2 )( e)41 Policy 701.32.34 The- Monroe County Growth Management Division shall annually supply FKAA and SFWMD with the Geneaffeney Public Facilities Capacity Report prepared in accordance with Capital Improvements Policy 1401.4.9. These annual reports shall include the latest information on land use, population trends, and growth management policies as well as facility capacity analyses using data supplied by service providers. [9i 5 ; 9j c 0 3(2)(Oni Policy 701.22.45 Monroe County shall oordinate and eex wat provide comments on the SFWMD plans, such as water supply, cost, needs and sources, and water conservation plans, as they are developed. Policy 70132.56 Monroe County shall continue to coordinate with the Cities of Layton, Key Colony Beach -ate Marathon, Key West the Village of Islamorada, and 19 FKAA as necessary to facilitate stem iide system -wide compatibility on such potable water - related issues as potable water levels of service, consumption projections, water conservation programs, and emergency management. Objective 701.43 Monroe County shall work cooperatively with Miami - Dade County to encourage land use planning and development controls which shall protect the recharge area of the Florida City Wellfield from potential sources of groundwater contamination, saltwater intrusion and overextraction [9i c 0 , (2)(b)S 9i 5 . 01 3(2) [§163.3177(6)(c)., F.S., §163.3177(6)(h)1.. F.S.I Policy 701.43.1 Protection of the Florida City Wellfield shall be accomplished through eentinued the Miami - Dade County Wellfield Protection Ordinance and the SFWMD Water Supply Policy Document. 91 5. and 4 9i 5 13 (2)(e)91 Polic 701.43.2 Monroe County shall seek inaintain an interlocal agreement with FKAA and Miami - Dade County. This agreement shall provide Monroe County with an opportunity to comment on land use and regulatory issues related to the Florida City Wellfield, aquifer and aquifer recharge area. It shall set forth procedures for review of land use and regulatory activities identified as having potentially significant impacts on the aquifer recharge and water supply systems especially concerning hazardous waste generation. Criteria for determination of significant impacts shall be included in the interlocal agreement. [9i a A. 9i 5 • •• 20 Objective 701.84 FKAA shall impfove its eap _Monroe County shall continue to coordinate with FKAA to ensure adequate capacity is available to provide for fire flows i the aF eas o o utlined i n Pehe,, 701 to ensure for protection of the public health, welfare and safety. r9T c n1 1(2)(bO4 63.3177(3)( a) 3., F.S.1 Policy 701.84.1 By the year , Monroe County shall coordinate with the FKAA, in accordance with its Capital Improvements Program, shaR continue to upgr- de r ading the distribution system toward the goal of providing fire flow capabilities i n throughout Florida Keys as funds and land are available:. Fire flows shall meet the provisions of the Florida Fire Prevention Code. Areas 2. Key W 3. Ever-ywhefe on US 1, exeept non developable areas 4 .Oeean -Kee€ 5. Key Goleny Beae.h. 6. La�4efi 7. Mar-atlan S— BuEk K&y 9. TavemieF 10. Pr F ire Flow Requir by Land Use • 12. Mo -uo me, Fc Vehicle 1,500 GPN Urban -G9ii 2P`rEisrr .- 9ii—mPFEial,and Gef an crcm r 2, 000 GPN4 21 All commercial facilities not along L�S 1 shall provide "on site" fire abatement, unless identified in the Agreement Between Monroe County and the Florida Keys Aqueduct Authority for Installation and Maintenance of Fire Hydrants in Unincorporated Monroe County. In all Policy 701.4.2 Monroe County shall require that at the time a construction permit is issued, adequate fire flow is supplied to the site in accordance with the Florida Fire Prevention Code. Objective 701.15 Monroe County shall continue to assist the FKAA with water conservation efforts and assist in implementing the FKAA's Water Conservation Plan consistent with SFWMD's Water Shortage Plan and Comprehensive Water Conservation Program. The County shall implement Policies 701.95.1 to further conserve potable water use. 5 .011 ( 2 )( b ) 4; of 5 . 013(2)(b)21 Policy 701.15.1 �e thc FKAA and cFWN4D, a nd other- a€feet ed organizations h adopt Land Development Regulations, whieh implement a xeri landseape > > and plumbing fi*tur-e effleieney stan eansist w t he -r a n d ater —y elem ents • of the FKA i W G ° atio Pl an th c�x�l, D Mod T ,1 ° C f S ,r1, vi �,.ViiJVl 1(411 V11 1 1Y11 W111 111V Vl �I I.ZD fL�ji IIdI �(j Florida. P Pr-- the— cadopt-i9n of the *efiseape landscape anew these- iffl-difi-an d-standaMs will be 1. tte to t h e c�x�MD f n c�v - crr cvicvr r in t f9i 5. 011(2)( e) 3; 9i 5.013 -- l�e— i`�ter Ee -- i�se��iei�-- i�ear� � - Within one (1) year of the adoption of the 2030 Comprehensive Plan, Monroe 22 s. INVOMMMIN Objective 701.15 Monroe County shall continue to assist the FKAA with water conservation efforts and assist in implementing the FKAA's Water Conservation Plan consistent with SFWMD's Water Shortage Plan and Comprehensive Water Conservation Program. The County shall implement Policies 701.95.1 to further conserve potable water use. 5 .011 ( 2 )( b ) 4; of 5 . 013(2)(b)21 Policy 701.15.1 �e thc FKAA and cFWN4D, a nd other- a€feet ed organizations h adopt Land Development Regulations, whieh implement a xeri landseape > > and plumbing fi*tur-e effleieney stan eansist w t he -r a n d ater —y elem ents • of the FKA i W G ° atio Pl an th c�x�l, D Mod T ,1 ° C f S ,r1, vi �,.ViiJVl 1(411 V11 1 1Y11 W111 111V Vl �I I.ZD fL�ji IIdI �(j Florida. P Pr-- the— cadopt-i9n of the *efiseape landscape anew these- iffl-difi-an d-standaMs will be 1. tte to t h e c�x�MD f n c�v - crr cvicvr r in t f9i 5. 011(2)( e) 3; 9i 5.013 -- l�e— i`�ter Ee -- i�se��iei�-- i�ear� � - Within one (1) year of the adoption of the 2030 Comprehensive Plan, Monroe 22 County shall implement a landscape ordinance consisting of water conservation measures which may include Florida Friendly provisions. Policy 701.15.2 During the development of updated Land Developm Regulati °land development regulations inaeeo eewith Pokey 70 .9 4 d+.--Monroe County shall coordinate with the FKAA skallto evaluate building codes, utility regulations, landscaping ordinances, and public education programs for implementation of water conservation measures. rnt c n, , �� �3 or c n, ����� ��, r , [ §163.3177(6 ), F.S.I Policy 701.15.3 I* Monroe County shall coordinate with the FKAA in accordance with i6 their Water Conservation Plan the FKAA ^ sha l w ith input f ^ M-A- e G-A ^ * , V >L >[ > JSS , • y , ^tee to implement a leak detection program and a conservation rate structure. Monroe County a*& shall coordinate with the FKAA, wi th input 4amthe SFWMD and other affected organizations, shallto formulate and initiate implementation of a joint public education program for water conservation. {9J 5.011(2)(e)3; °T 5 . 013(2 )( e)4] Policy 701.15.4 Monroe County -and th RK ^ ^ shall continue to comply with SFWMD water use restrictions including all Phase I and Phase I (modified) water use restrictions when water shortages are declared by the SFWMD. 5.011(2)(e)3; or c ni 3(2)( e )4j Policy 701.15.5 Monroe County shall coordinate with the Florida Department of Health and Rehabilitative ce,..,:ees (HRS (DOH ) to permit utilization of gfey reclaimed water storage systems and utilization for all exterior irrigation and flushing purposes. Upon receipt of authorization from HRo policies shall be developed to implement the use of grey reclaimed water storage systems where economically feasible. f°- �;T(2)(e)3; 9i 5.013(2(e)41 Policy 701.15.6 Monroe County shall permit and encourage rainwater ---- -- - -- - -- --_� -- -- ---- ---- a ». -.. - -, -- -, 1.. ---- 9 .,..,w. •...,,..... — w in capture for all non - potable uses and for safe household potable uses [9i 5.011(2)(e)3; 9r c 013(2)( )n, l§163.3177(6)(c)., F.S.1 Policy 701.15.7 By januafy 4, 1997, Monroe Geunty shall adopt Land Development .wb......,.oaa.a .•aaavaa establish u > vaaauc z Fesi lea l an d n r esidenti a l (See Future h U Obje ...�,a.. va.ua.ca axaau aavaa iVJauvaacaa l 101.2, 1 01 . 3 , and 1 and suppef ing pok eies). in developing the Point System, Monr County sh Within one (1) year of adoption of the 2030 23 Comprehensive Plan. Monroe Countv shall evaluate the hermit allocation and point system to consider assigning a positive point rating to developments utilizing alternative water collection systems sueh as eisteffis, which conserve potable water supply. [°T�(2)(e)3; °T 5 . 013(2 )( e)41 Policy 701.95.8 As the water conservation measures set forth in Policies 701.15.1 through 701.95.7 are implemented, Monroe County shall re- evaluate the adopted potable water levels of service through the evaluation and appraisal report process . Objective 701.4-06 In coordination with the FKAA, Monroe County shall continue to maximize the use of existing facilities and discourage urban sprawl thfough implementation of Potable . mT c ni , (2b)31[§ 163.3177(6)(c)2., F.S.1 Policy 701.6.1 Monroe County shall annually evaluate proposed FKAA capital improvements for inclusion in the annual update of the County's CIE Schedule. Policy 701.6.2 Existing facilities shall be maximized by encouraging capital developments in already developed areas and discouraging extension of facilities to undeveloped areas. r fras�ns�ris • ••• •. • • •. • • 24 I IIMF i It EfF WW _ .. •. . • • IMMAII I IIMF i It EfF WW _ .. •. . • • 5.2 Natural Groundwater and Aquifer Recharge Element GOAL 1101 Monroe County shall protect the quality and quantity of water in the potable water aquifer and in the freshwater lens systems so as to ensure public health, conserve the public water supply, and preserve ecosystems dependent upon freshwater. 10i 5 [ §163.3177(6)(c), F.S.I, Objective 1101.1 Monroe County shall work cooperatively with Miami - Dade County to encourage land use planning and development controls which shall protect the recharge area of the Florida City Wellfield from potential sources of groundwater contamination saltwater intrusion and over - extraction (See Potable Water Objective 701.4 and related policies.) [9i5. (d), (J163.3177(6) F.S.I Obiective 1101.2 �, .. ..____...... ., _iiv, _.�vaaa VV vvua aJ Jaawaa aaau aaav 1a vJaa .. uaVa aVIIJ J'Jaa/IIIJ u lf u •e d F M. the Flefida Keys and shall ado w hich nrnteet the le f of l ess o f ..e,.la p 1 n f om th o f g n r ra Vavva aaav avaaJVJ as Viii aVJJ Va aVVIIC{I LV l.JVIVIIT r9i c n1 1(2)(b)c. or 5 E6�t6a'. �v7�� r� Monroe County shall provide for the protection of groundwater within the unincorporated areas. 25 MA LO'NEL-VA1104rap"TA 2211-7-mall 25 Policy 1101.2.21 Monroe County shall undertake activities which shall reduce pollutant entry into groundwater, summarized as follows: 1. Monroe County shall develop and implement permitting, inspection and enforcement procedures designed to reduce pollutant discharges into groundwater from: a) on -site disposal systems (See Sanitary Sewer Goal 901 and related objectives and policies); b) secondary sewage treatment plants and injection wells (See Sanitary Sewer Goal 901 and related objectives and policies); affd C) stormwater runoff (See Drainage Element Objective 100131 and related policies); d) pesticides used for mosquito control — Monroe County shall immediately take oordinate with the Florida Keys Mosquito Control District to promote mosquito control techniques which will reduce the entry of pollutants from aerial pesticide applications into groundwater (See Genser- ation an Coast �►,r,,,,,,,.o Obje rn r elated po fi ie \.V{AJ LCLl i�aua e , 1 i an e) fuel storage tanks — Monroe County 14RS Unit shall coordinate with the Department of Health (DOH) to continue to undeitake undertakinc activities designed to reduce pollutant discharges into ground and surface waters from aboveground and underground fuel storage tanks (See Conservation and Coastal Management Objective 202.12 and related policies); and f) hazardous wastes — Monroe County shall continue to undertake activities which support existing state and federal laws pertaining to the handling, transportation and disposal of hazardous wastes (See Solid Waste Objective 801.5 and related policies.) [9i 5 9- b) �(3)(m 9i c ni 3(2)(b) 9 and 10 I N. N. ■ ` ■ n 1'a 26 1 System. [9J 5.011(2)(c)4; 9J 5.013(2)(b)1 and 9] Policy 1101.2.42 Monroe County shall continue to restrict the percentage of impervious surfaces on development sites through application of the Open Space Requirements in the Land Development RegulationsCode. These regulations shall be met or exceeded in order to minimize impervious areas and to protect freshwater lens recharge areas. [9J 5.011(2)(c)4; 9J 5.013(2)(b)1 and 9]11163.3177(6)(c),F.S.1 Policy 1101.2.53 evaluation theMonroe County shall consider altering the minimum required open space ratios, and other development regulations, to protect the quantity and quality of groundwater in the freshwater lens systems. —The-County-shall 9J 5.013(2)(b)1,2,9 and 10] f§163.3177(6)(c), F.S.1 1111My 1101.2.4 Monroe County shall maintain land illikmentiltulatidirthat prey groundwater contamination during resource extraction operations. Such regulations shall require onsite retentio int source ollution controls inecting FDEP and AcOE requirement Ob eetivc >>0 3 freshwater lens system. [9J 5.011(2)(b)5; 9J 5.013(2)(b)2] Policy . . water testing. [9J 5.011(2)(c)4; 9J 5.013(2)(b)1 and 9) Policy . , 5.011(2)(c)4; 9J 5.013(2)(b)1 and 91 27 1 1 0 9 .1-- ft— XUR 5.4 Conservation and Coastal Management Element ,K17� i�►�i it Monroe County shall conserve and protect potable water resources and cooperate with regional efforts to ensure the continued availability of high quality potable water. [9i 5.011 R 163.3177(6)d. 9i c 0 3i.b., F.S.; § 163.3177(6)d. } .c., F.S.I Objective 211.1 Monroe County shall encourage the use of water conservation strategies, including, but not limited to cisterns, on -site stormwater collection systems used for irrigation and bio- swales, and work cooperatively with FKAA and Miami - Dade County to encourage water conservation efforts and assure that land use planning and development controls are maintained which shall ffetec-t rop tects the recharge area of the Florida City Wellfield from potential sources of groundwater contamination and saltwater intrusion. (See Potable Water Objective 701.43 and related policies). {9j- c.0 3(2)(b`'" f § 163.3177(6)d.2.b., F.S.; § 163.3177(6)d.2.c., F.S.] Objeetive 2H.2 Policy 211.1.1 Monroe County shall continue to assist the FKAA with water conservation efforts and assist in, including_ implementing the FKAA's Water Conservation Plan, consistent with SFWMD's Water Shortage Plan and Water Consumption Guidelines, and shall implement measures to further conserve potable water. (See Potable Water Objective 701.9--5 and related policies). [9i 5 R163.3177(6)d.2.b., F.S.; §163.3177(6)d.2.c., F.S.] nNeetiye 211 Policy 211.1.2 By januar-y Monroe County shall idenfifyhas identified the freshwater lens system and associated recharge areas of the Florida Keys and --sue implement Pf:8gFaffiS as noted within Water Resources of Big Pine Key, Florida, (Hanson, 1980). Within one (1) year after the adoption of the 2030 Comprehensive Plan, the County shall adopt land development regulations that regulate the storage and use of hazardous materials in recharge areas, prohibiting new water withdrawals, and phasing out existing water withdrawals to protect freshwater lenses. (one AT.,r,, G r-e ,,,,a,. atef Aquif R ee h ar - ge Obje b yes 1101 d 1101 and related pohei es)[9i 5.013( f § 163.3177(6)d. F.S.; § 163.3177(6)d. F.S.I 28 5.4 Future Land Use Element GOAL 101 Monroe County shall manage future growth to enhance the quality of life, ensure the safety of County residents and visitors, and protect valuable natural resources. rot 5 j§163.3177(1), F.S.1 Objective 101.1 Monroe County shall ensure that all development and redevelopment taking place within its boundaries does not result in a reduction of the level -of- service requirements established and adopted by this comprehensive plan. " Co shall ensure that at the fifne a developffient per is issued, adequate publie faeilifi are available to sef�ve the development at the adopted - level -- orser s*,,ndai.as coneuFfent with the impaets of sueh development. r9j 5 . 006 ( 3 )( b ) 1 Further, Monroe County shall ensure that comprehensive plan amendments include an analysis of the availability of facilities and services or demonstrate that the adopted levels of service can be reasonably met. f § 163.3177 & 163.3180, F. S.l Policy 101.1.1 Monroe County shall adept maintain level of service (LOS) standards for the following public facility types required by Chapter 9-J--5163, F. A.C. r-aads, sanitary sewer, solid waste, drainage, and potable water- Additionally the County shall maintain LOS for roads, and parks and recreatio pai-7atransit. The LOS standards are established in the following sections of the Comprehensive Plan: 2. The LOS for potable water is established in Potable Water Policy 701.1.1; Policy 101.1.3 Facilities for potable water, sanitary sewer, solid waste and drainage shall be in place and available to serve new development no later than the issuance of the certificate of occupancy or its functional equivalent. If facility improvements are needed to ensure that the adopted level -of- service standards are achieved and maintained, prior to commencement of construction, a developer is required to enter into a binding and legally enforceable commitment to the County to assure construction or improvement of the facility. f 163.3180, F. S.l 5.5 Capital Improvements Element Objective 1401.4 Monroe County shall coordinate land use decisions and fiscal resources with a schedule of capital improvements in order to maintain the adopted level of service 29 (LOS) standards for both previously issued development orders and future development. f nT Trr - 5.04 3.3177 (3)(ba)3 -ate., F.S.1 Policy 1401.4.1 Monroe County shall adopt and maintain level of service (LOS) standards for the following public facility types: roads, sanitary sewer, solid waste, drainage, potable water, and parks and recreation. The LOS standards are established in the following sections of the Comprehensive Plan: 2. The LOS for potable water is established in Potable Water Policy 701.1.1; Policy 1401.4.4 Public facilities and services needed to support development shall be available eeneufFent with the impaets of development, in accordance with the adopted levels of service referenced in Policy 1401.4.1 and Chapter- 9i 5.0055, F.A.G_ Development approval may be phased to allow the provision of public facilities and services necessary to maintain the adopted levels of service. {)J- c n1 6(3)( e )64 Policy 1401.4.5 Monroe County hereby adopts a Concurrency Management System to ensure that facilities and services needed to support development are available concurrent with the impact of development. The Concurrency Management System shall ensure that the County shall issue no development order or permit which results in a reduction in the level of service (LOS) below the adopted LOS standards referenced in Policy 1401.4.1 for those public facilities that are subject to the system. The guidelines established in Policies 1401.4.6, 1401.4.7, 1401.4.8, 1401.4.9, and 1401.4.10 shall ensure that concurrency is successfully implemented. Policy 1401.4.6 The following guidelines identify the stages in the development review process when the test for concurrency must be met. 1. Preliminary Development Order Stage - A preliminary development order is a development order that precedes the issuance of a building permit, such as a subdivision plat, development plan, certificate of compliance, conditional use permit, or development of regional impact development order. A proposed development must receive a conditional concurrency determination prior to receiving a preliminary development order. 30 2. Final Development Order Stage - A final development order is a building permit or any other development permit authorizing the construction or expansion of a structur an increase in development intensity, or a change of use requiring a new certificate of occupancy. A proposed development must receive a final concurrency determination prior to receiving a final development order. Policy 1401.4.8 The following guidelines identify the minimum criteria necessary to meet the concurrency requirements of each public facility type. 1. The concurrency requirements for potable water, solid waste, sanitary sewer, and drainage facilities and services shall be satisfied if one or more of the following conditions are met: a) the necessary facilities and services are in place at the time a development permit is issued; or b) the necessary facilities and services are in place at the time a certificate of occupancy, or its functional equivalent is issued. b) t he developmen permi -is issued subj'e t o the eendi ion that is of the d ffie.,t oeeur- of e) the neeessi aeili ies —afe under- eenstFue at the fifne -a p o ; t i s i ssu e d; e 2. The concurrency requirements for recreational facilities shall be satisfied if one or more of the following conditions are met: a) conditions 1(a) or 1(b) or- 1(e) listed above or, in the case of acreage for parks and recreational facilities, which shall be dedicated to or acquired by the County prior to issuance of a building permit, or funds in the amount of the developer's fair share are committed no later than the approval to commence construction or 31 b) a binding exeeuted t is - iirpraEe at the tline tl-1 development ent pe mit i r issued — hiehpf id es f er- the eemmeneefnent of the actual eenstmetion of the fequired f seFyie2s within one iai e) enforceable development agreement guarantees that the necessary facilities and services will be in place wi thin yeaf a with the issuance of the applicable development permit. An enforceable development agreement may include, but is not limited to, development agreements pursuant to section 163.3220, F.S., or an agreement or development order issued pursuant to Chapter 380, F.S. 3. The concurrence requirements for roads shall be satisfied if one or more of the following conditions are met: ) conditions 1(a) or 1(b) listed above; or b) a binding executed contract is in place at the time the development permit is issued which provides for the commencement of the actual construction of the required facilities or provision of services; or c) an enforceable development agreement euarantees that the necessary facilities and services will be in place with the issuance of the applicable development permit. An enforceable development agreement may include, but is not limited to, development agreements pursuant to section 163.3220, F.S., or an agreement or development order issued pursuant to Chapter 380, F.S. Policy 1401.4.10 Monroe County shall use the following guidelines for interpreting and applying level of service standards to development order applications. For the purposes of this policy, reserve capacity refers to the capacity of existing public facilities plus the capacity of public facilities which do not exist but which meet the applicable requirements of Policy 1401.4.7, less the existing demand for those facilities and the demand expected to be created for those facilities by approved but unbuilt development as determined by the databases in Policy 1401.4.9. 1. Potable Water- The County shall not render a final concurrency determination unless the quantity of water available under the FKAA Consumptive Use Permit meets or exceeds the estimated water 32 demand of the proposed development together with the estimated water demand of all existing and committed development. 5.6 Energy and Climate Element Policy 1502.1.5 Within five (5) years after the adoption of the 2030 Comprehensive Plan, Monroe County shall initiate an inventory of existing and planned infrastructure up to the 2030 horizon, based upon the vulnerability mapping identified in Policy 1502.1.4, for capacity to accommodate projected sea -level rise over the life expectancy of that infrastructure. Monroe County shall identify the infrastructure within those areas, its useful life and any retrofits or capital projects necessary to address the impacts of sea level rise. These strategies may include defense, accommodation, or and retreat projects, or not building planned infrastructure in vulnerable locations, to address the impacts of sea level rise. Monroe County will consider developing design criteria, in conjunction with a broader asset management planning_ process. Policy 1502.1.7 Monroe County shall ensure that new, renovated and replacement up blic facilities and infrastructure, such as streets and bridges, water and wastewater treatment plants, police stations and fire stations, and any other public facilities that the County has authority over, are designed in a manner which considers the useful life of public facilities and infrastructure. The County shall also consider the potential impacts from climate change, including rising sea levels and shoreline stabilization needs, on its infrastructure and public facilities. Policy 1503.1.5 Consistent with the Lower East Coast Regional Water Supply Plan, Monroe County shall encourage FKAA to continue expanding water auditing programs to increase the scope of the audits and identify opportunities to reduce system leaks and promote water conservation retrofitting_ 33 Policy 1502.1.6 Within five (5) years after the adoption of the 2030 Comprehensive Plan, Monroe County shall consider incorporating a planning, design and permitting standard for infrastructure and public facilities that may include a sea level rise assumption of Y -7" by 2030 as developed by the Southeast Regional Policy 1503.1.6 Within one (1) year after the adoption of the 2030 Comprehensive Plan Monroe County shall develop policies to increase water conservation which may include the adoption of a recognized standard such as the South Florida Water Management District's "Water Star" or EPA's "Water Sense" programs. Policy 1503.1.7 Within five (5) years after the adoption of the 2030 Comprehensive Plan Monroe County shall determine the appropriate climate change considerations (including but not limited to, emergency management, flood risk, storm surge threats to potable water supply, the potential for changing habitat and landscapes, the need for shoreline stabilization and the potential impacts to infrastructure necessary to serve proposed uses) to evaluate when reviewing land use amendments. 6.0 REGIONAL ISSUES IDENTIFIED IN REGIONAL WATER SUPPLY PLANS 6.1 Lower East Coast Water Supply Plan Update, September 12, 2013 The sole source provider of potable water to Monroe County is FKAA, whose wellfield is located in Florida City. The Lower East Coast Water Supply Plan Update indicates that the FKAA wellfield as a Utility At Risk from saltwater intrusion, but also states that the FKAA is a permitted Floridan Aquifer User, which should offset any anticipated drought- driven salt water intrusion event. FKAA also operates RO facilities in Marathon and Stock Island. 6.2 Integrating Climate Change & Water Supply Planning In Southeast Florida, Southeast Florida Regional Climate Change Compact, June 10, 2014 The Southeast Florida Regional Climate Change Compact, which includes Palm Beach, Broward, Miami -Dade and Monroe Counties, predicts that the sea level will rise between 9 and 24 inches by 2100 (the Compact's A Unified Sea Level Rise Projection for Southeast Florida [April, 2011] predicts that the sea level will rise between 3 and 7 inches by 2030). This may have implications regarding the ability of the local utility to provide fresh potable water from the Biscayne Aquifer to Monroe County as the salt water intrusion line shifts westward towards the FKAA wellfield. Monroe County's climate change and sustainability consultants have recently summarized hydrologic modeling by the United States Geological Survey that suggests relatively low risk to the FKAA wellfields in Florida City under even the worst -case 2060 sea level rise scenarios. However, FKAA continues to monitor the most current data and analysis regarding this issue. 34 7.0 REFERENCES • Florida Keys Aqueduct Authority, 20 -Year Water System Capital Improvement Master Plan, December 2006 • Florida Keys Aqueduct Authority, Annual Water Demand Update Through 2030 • Florida Keys Aqueduct Authority, Annual Water Demand Update by Municipal Boundary • Florida Keys Aqueduct Authority Projected 5 -Year Capital Improvement Plan • Keith and Schnars, P.A.and Fishkind and Associates, Monroe County 2010 -2030 Population Projections, March 15, 2011 • Monroe County Growth Management, Monroe County 2010 Comprehensive Plan • Monroe County Growth Management, Monroe County 2030 Comprehensive Plan Update • South Florida Water Management District, Lower East Coast Water Supply Plan Update, September 12, 2013 • Southeast Florida Regional Climate Change Compact, A Unified Sea Level Rise Projection for Southeast Florida, April, 2011 • Southeast Florida Regional Climate Change Compact, Integrating Climate Change & Water Supply Planning In Southeast Florida, June 10, 2014 8.0 EXHIBITS Exhibit A: Section 7.2 of the Florida Keys Aqueduct Authority 20 -Year Water System Capital Improvement Master Plan, December 2006. 35 Exhibit A to Monroe County 10 -Year Water Supply Facilities Work Plan Update SECTION 7. CAPITAL IMPROVEMENT PROGRAM 7.2 Water Infrastructure System 7.2.1 Major System Upgrades The CIP identifies many short- and long -term improvements to the water transmission, distribution, water storage, raw water supply, and the water treatment plants. Upgrades to the Water Infrastructure System will increase water treatment and storage capacities, and improve flows and pressures to meet anticipated water demands. Significant upgrades and proposed new facilities to the water treatment plants are planned to improve the reliability and quality of FKAA's drinking water. A specific goal is to provide high quality water that will meet future regulatory standards and will be able to meet projected water demands. Major improvements to the water system include a new Floridan aquifer wellfield that will serve a new LPRO treatment facility at the J Robert Dean WTP in Florida City, multiple rehabilitation or upgrade projects at both the Kermit H. Lewin Desalination WTP and the Marathon Desalination WTP facility to increase reliability and capacity to meet emergency and peak day flows, and various transmission/ distribution line replacements, distribution pump station upgrades, and improved water storage tanks to improve delivery capacity of the system. Exhibit 7 -2 shows all planned project improvements from 2006 through 2025 and associated order of magnitude cost estimates. The total estimated cost (in 2006 dollars) of these improvements is $208,606,402 during the next 20 years. EXHIBIT 7.1 20 -Year Water Infrastructure Capital Improvement - Order of Magnitude Cost Summary Including an Annual Item Amount 3% Inflation Water Supply Wells $11,575,000 $12,695,000 Water Treatment Plants $41,886,368 $45,224,000 Transmission Mains and Booster Pump Stations $58,899,034 $72,725,000 Distribution Mains $47,500,000 $64,676,000 Distribution Pump Stations and Ground Storage $33,546,000 $43,949,000 Facilities and Structurel $15,200,000 $16,223,000 20 Year Water Infrastructure Capital Improvement Program - GRAND TOTAL $208,606,402 $266,492,000 Note: 'Facilities and Structures are not included in the detailed discussions in previous sections of this Master Plan document. Only order of magnitude costs included in Section 7 (per FKAA). 7.2.2 Basis of Project Cost Estimates For master planning purposes, planning level cost estimates are order -of- magnitude esti- mates. As defined by the American Association of Cost Engineers, order -of- magnitude cost estimates are believed to be accurate within a range of 30 percent below, to 50 percent above, actual costs. WPB310127161224.DOC/061640010 7.3 WB122005005DFB 3 2010 4 2011 51 Immediate TOTAL 1 2012 B 2013 7 2014 6 2015 9 10 2076 Mid -term Subtotal 1 2017 2018 13 14 15 18 17 18 19 Lon •term a 2018 2020 2021 2022 2023 2024 2025 Subtotal Total $ S l a 6,160,906 a a $ 8,160,IX a $ 2,415,000 $ 2,415,000 $ $ 2,415,6[ $ $ E !,000,000 $ _ $ $ 1,000,00 $ 9,180,000 $ - $ 2,415,000 $ - S - S - a 2,415,000 a - a S - E $ - - S $ 11,575,00 $ $ E 5.18,3 $ -- - - - -- 18,323,39 $ 6,900,000 $ 6,900,00 S $ 1,836,400 S 1,636,400 $ $ 9,836,40 S 9,6!7,568 $ S $ 3,817,56E 2,658,003 E - a $ 2,659,003 a 8,950 000 $ a $ 8,350,000 a $ - $ 40,049,966 $ $ 1,836,400 $ S E - a 1,896,400 $ - S a E E - S - $ $ S $ $ 41,886,366 a $ s $ 200,666 a $ $ 296,666 E 73,862,000 $ _ $ $ 13,662,000 $ 9,188,000 $ S $ 3,188,060 E 1.500.000 $ a $ 1,500,000 ONV3101569546.x18/0 6 24 9 0 01 0 6f 3 Exhibit 7 -2 1 1 ' 20 -Year Capital Improvement Plan 1 2 3 4 5 Immediate 6 7 B 9 10 Mid -term 11 12 13 Project Name Project 2007 2006 2009 2010 2011 TOTAL 2012 2013 2014 2015 2016 Subtotal 14 15 16 17 18 19 Long -term 2017 2018 2019 2020 2021 2022 2023 _2024 2025 Subtotal Total Marathon 18- inch Transmission i Main Replacements 18 -inch $ - $ 300,000 $ 300,000 ; - $ 300,000 Transmission Main - placement - N. Roosevelt $ 1,572;OD0 $1,572 $ 3,144,DD0 E Phase tI $ $ 3,144,000 Cathodic Protection $ 2,118,334 $ 2,118,394 $ Upsize diesel $ $ 2,118,334 J. Robert driven pumps 1 and Dean WfP 2 J. Robert Install new 5 MG $ 302,000 S 302,000 $ $ - $ 302,000 Dean V TP storage tank $ - $ 4,855,000 S 4,855,000 Key Largo Install 3rd electric $ $ 4,855,000 Booster PS transmission purnp, E $ 251,850 $ 251,860 Plantation Key $ 6 251,850 Booster PS $ S 4,209,000 $ 4,209,000 S 8418000 Marathon , , E $ 8,418,000 Pump Station Engine 8 Pumps - In . 1075 $ 907,000 $ 907,000 $ Marathon Add a second 3 MG $ - S 907,ODD Booster PS Istoragetank. 1 $1,430,500 $ 1,430,50D $ 2,861,000 S Marathon Install 3rd electric $ $ 2,861,000 Booster PS pump y _ $ 251.650 $ 267,850 Lower Keyes $ $ 251,850 Booster Pump Station #1 $ $ 4,2D9,OOD $ 4,209,000 $ 8,418,000 Lower Keyes $ $ 8,418 DOO Booster Pump Station #2 $ E Ramrod $4,209,000 $4,209,000 $ 8,418,000 $ 8,418,000 Booster PS S - $ 104,000 S iD4,000 $ Total project Costs ; - S 7,578,334 E10,058,000 S 5,510,0011 $3,304,500 $ 1,430,500 $ 27,882,334 E 9,364,000 E 4,209,000 $ - $ 4,816,700 $ 4,209,000 $ 22,598,700 $ $ - $ $ $ - $ 104,OD0 - - S - S 54,209,006 $4,209,000 $ 8,418,000 $ 58,899,034 Distribution Mains S $ Replace Old $ - Galvanized Mains $ 341,000 S 341,000 $ Ups¢e Small- E $ 341,000 Diameter Mains to 4 inch 8 other upgrades $ 1,607,000 3 1,558,500 1 5 1,558,500 $2,500,000 $ 2,500,000 $ 9,724,000 $ 2,500,000 $ 2,500,000 $2,500,000 $ 2,500,000 $ 2,500,000 E 12,500,000 $ 2,50QDOD $2,500,000 $2,500,000 $2,500,000 $2,500,000 $2,500,000 $2,500,000 $2,500,000 Cudjoa Key $2,500,0617 $22,500,000 $ 44,724,000 Additional Distribution Main Header $ 552,000 $ 652,000 ; Islamorada $ $ 552,000 Distribution Install distribution I PS main header $ 941,500 $ 941,500 $ 1,883,000 $ Total Distribution Mains Project S $ 2,500,000 $ 2,500,000 $ 2,500,000 $2,500,000 $ 2,500,000 $ 12,500,000 $ 2,500,000 S 2,500,000 $2,500,000 $ 2,500,000 $ 2,500,000 $ 12,500,000 $ 2,500,000 $2,500,000 $2,500,000 $2,500,000 $2,500,000 $2,500,000 ;2,500,000 52,500,000 52,500,000 $ - $22,500,000 $ 1,863,000 $ 47,580,000 DisMbutfon Pump Station and Storage Immediate Ocean Rest Additional 1.0 MG Storage $ Long -term New Pump Station - $ 860,000 3 660,000 $ 00 $ S 1,720,000 Lake Surprise and 0.75 MG T1,126.5-W$ - Stora tank $ $ 1,126,500 00 Repla Repla ce and S 2,253,0110 Rock Harbor Upsize existing Station S $ 536,000 S 536,000 00 Rock Harbor Install 0.5 MG $ $ 1,076,000 Storage Tank ; $ 405,000 $ 405,000 $ 810,000 S Rock Harbor Install athird 0.5 MG Tank E - - $ 810,000 New Larger Pump $ $ 810,1700 $ 910 $ 610,000 Tavernier Station and Ncw Larger Storage tank I. (1.0 MG) $1 $ 1,318,500 S 2,637,000 $ finch tap and 8" fill $ $ 2,637,000 Tavernier line S 76,000 5 76,000 $ 152 E $ $ 152,000 GNV3101589546.xIsfM490010 2 of 3 Exhibit 7 -2 20 -Year Capital improvement Plan 1 2 3 a 5 Immediate 8 7 a 9 10 Mld -term 11 12 13 1a 75 18 Project Name Project J 2007 2008 2008 2010 2011 TOTAL 2012 2015 2014 2015 2016 Subtotal 2017 2018 2019 2020 2021 2022 17 2023 18 2024 19 2025 Long -tern Subtotal Total Install 8•inch distribution main Tavernier header along both sides of US-1 where required $ 646,000 5 646,000 $ 1,292,000 $ New Pump Station $ $ 1,292,000 Plantation Key and 1.0 MG Lower Storage tank New Pump Station $ - $ $ 1,325,500 $1,325,500 $ 2,651,000 $ 2,851,000 Matecumbe and and 0.5 MG key Duck Storage tank New Pump Station § _ $ $ 974,500 $ 974 500 $ 1,949,000 $ 1,949,000 Key/Grassy and 0.75 MG Key Storage tank Install New and $ _ § $7.133,500 $1,133,500 § 2,Z87,000 $ 2,267,000 Crawl Key Upgraded Pump Station Install New 6-inch $1,090,OOD $ 1,090,DOD $ _ $ $ 1,090,000 Crawl Key tap and 8 -inch (assumed) Fill Line 5 109 $ 109,000 $ Replace and $ $ 109,000 Crawl Key Upsize Storage Tank(101 '� $ $ 1,464,000 $ 1,464,000 § $ 1,464,0110 Vary Cut Install New 0.5 5 MG Storage Tank $ 811),000 $ 810 § Demolish Existing — $ $ 810,000 0.5 MG Storage Vary Cut Tank and Install New 0.5 MG Storage Tank § $ 969,000 $ 869,000 $ $ 869,000 891h Street $ $ 33rd Street Replace Existing $ $ Pump Stall n § - S 1,138,D00 § 1,196,000 $ $ 1,138,000 Replace Existing - 33th Street 1).5 MG Storage Tank with New 0.5 MG storage tank New Pump Station $ 897,000 $ 897,000 $ 897,000 Ramrod and 0.50 MG Storage Tank New Pump station - $ _ $ $ t ' g �'� $ 1,900,000 $ 1,900,000 Cudjoe Key and 1.OMG Storage Tank $ 1,750,D00 $ 1,750,000 _ Replace Pump $ 7,750,000 Summerfand Station and Storage Key tank, New 0.5 MG tank New Pump Station $ $ $ 1,932,000 $ 1,932,000 $ 1,932,000 Lower Sugarloaf and Storage Tank, Stock Island New, 0.5 MG tank Replace Existing $ $ 51,800,000 $ 1 $ 1,900,000 Dl' Mbutiar Pum Station — Pump $ 2,850,500 $ - $ 7,840,000 $ 2,070,000 $4,151,1100 _ § 1,809,000 $ 860,000 § 1,126,500 $ 9,459,500 $ 2,070,000 $ _ _ � _ _ $ - $ 2, 070,000 Total Olstrlbutlon Station § - $ 1,750,000 $ - S - $3,238,600 11,400,000 S 5,1fi7,500 $2,960,000 $2,108,000 $1,949,500 $2,797,000 $ § - § - E - $14,308,000 $ 33,546,000 Ficilf0e , antl Structure Desal Sewall $ Repairs 3073 $ 750,000 $ 3,250,000 $ 4,000,000 § Rehab Admin $ - $ 4,()00,000 BldglGara a 3081 $ 400,000 $ 3,400,000 $ 3,400,000 $ 7,200,000 $ Marathon $ $ 7,200,000 Central Warehouse 3077 $ _ Customer - Servica Meter .119 3091 $ 425,00 $ 4 $ 8 80,000 -- DESAL/Stock -- $ _ _ ,- � $ - $ 850,000 Islandr -ower _ Keys Garage Wastewater 3083 $ 200,000 $ 200,000 $ - Marathon $ $ 200,DDO Customer Service Center 3077 $ 300,000 $ 1,ODD,ODD $ 1,650,000 $ 2,950,000 $ Total Project Costs $ $ 2,075,000 $ 8,076,000 $ 5,050,000 $ - S - $ 15,200,000 $ - $ - $ $ - $ § § $ $ 2,950,000 $ $18,263,117 44,082,986 §33,461,200 9,044,000 $ 6.781,551) $112,632,302 18,015,000 $12,763,400 $3,360,000 $ 8,443,2D0 10,168,500 § 50,750,100 § 7,667,500 4,800,000 $4,80§,000 $4,449,b00 $b,297.000 $2,500,000 $2,500,000 $ $6,709,000 $ $8,70B $ $46,224,000 S 75,200,000 208,606,402 GNV3101569546.xls]OS2490010 3 of 3 Exhibit 7.2 20 -Year Ca iial Im "ment Plan Costs in initiated Dollars 1 2 3 4 5 Immediate 8 7 a 9 101 Mid-term 11 12 13 14 151 16 17 18 1B Lon -term Project Name Proect 2008 2007 2008 2009 2010 2011 Subtotal 2012 2013 2014 2015 2016 Subtotal 2017 2018 2019 2020 2021 2022 2023 2024 2025 Subtotal Total WamrS F y - -- — _.— S - J. Robert Fora 4.5 MGD __ � — _ - Dean WTP WrP -Three2 mgd - Phase 1 RO wells and orre Facile standby 8 - $ 1,751,000 $ 3,819ADO $ 3,125,000 S - S - S 8,696,000 $ - S $ - S - $ - S - $ - $ $ $ $ S J. Robert - - - - 3 $ $ $ 6 8,695,000 Dean WrP For an additional Phase 2 RO 1.5 MOD WfP -One I FOCility 2 mild well $ - $. - $ - 8 - $ S - S S $ 2,970,000 -5 1 $ - S - S 2,970,01ID $ - $ - $ E S - $ - $ $ $ 2,970,000 — Ocean Reef - Oceen Reef supply welts are Wrp 4.5 MOD incluo'edin the RO Facility water frastnrem Wotan. 5 - S - $ - $ - S - $ - f $ - 5 - S - S - $ - S - S - $ - S - It - $ - $ - S - $ - $ - - Aquifer Storage and Recovery (ASR) 1073 $ S 1,030,000 $ - $ - $ E - $ 1,030000 $ - $ - $ - $ - $ - S - $ - S - 5 S $ Torn] Project - _ g $ _ $ - S - E E 1,030,000 costs $ f 2,781,0011 1 $ 3,819,000 S 3.12-%000 S f $ 10,725 801 S $ 2,970,000 $ $ f S 2,970.000 $ S $ S S E $ E S $ f 12 695.000 weer rrebnenr S E J. Robert $ Dean WfP Phase 1 RO 4.5 MOD RO S - $ 412,000 $ 9,507,000 S 9,793,000 $ $ - $ 19,712,000 $ - $ - $ - S - $ - $ - $ - $ $ $ E ! J. Robert 1 DIW for - E - $ - $ - E - S - S 19,712,000 Dean WTP Concentrate Phase 1 RO Disposal $ 31380 $ 3,770,000 $ 7,430,010. J. Robert $ 7,430,000 Dean WfP An additional 1.5 Phase RO MGD RO $ - $ - S - S - $ - 8 - $ $ - $ 2.259,000 $ - S - $ E 2,259,000 $ - $ - $ - $ - S - $ - $ $ - $ - $ $. 2259,000 Komi fi. t . - Lawin RO Desalinatlon Wrp Membrane Stock island Replacement Construction 1082 $ - 5 1,988,000 $ 2,025,000 E - $ - $ - f 3,981,000 5 - $ - $ - $ - $ - $ S S $ S $ Marathon Ro - - $ - $ 8 $ $ $ 3;981p00 Desalination WTP Membrane replacemera and Plara Marathon Upgrades Construction Cost $ S - $ 1,410,000 $ 1,453,000 $ S - $ 2,663,OD0 $ - $ $ - 3 $ - S - S - S $ S Ocean Reer - - $ - $ - $ - 3 - $ - - S $ 2,863,000 4.5 MOD RO De"dinali0n WTP 1.5 MOO(FKAA's Membrane cost share Plant component) "Npte- Consbuc5on coViotovldedby Cost O tion FKAA $ $ 361,000 $ 4,456,000 $ 4,152,000 ll - E - $ 8.888000 Is - 8 $ - $ - $ - S $ $ E S - E - E - E $ E S S 8,969,000 Total Project Coats $ - S 2,739,000 521,056,000 $19,168,000 $ - E $ 42,995,001) $ $ 2,259,000 1 $ S f - f 2.258,900 S IS S - $ $ $ S E $ $ S 45,224,000 T7anaftpa Shins end800sfer PemP Slat— S $ - Replace 36 S Inch transmission Other 16 -mile Main stretch se meets $ S $ 212,000 f - $ - $ - $ 212,000 S $ $ - - - 8 $ - $ $ $ $ $ - $ - $ _ $ _ $ _ 5 - S S 212,000 Replace 36- inch tra nsmission MM 9398 Main Replacement $ S 4,691,000 $ 9,663,000 $ $ - $ - $ 14,354,000 $ - $ - $ - 5 S - S $ $ $ $ 12 -inch Ocean $ - $ - S - S - 5 - E 5 14,354.000 reef Transmission Maim Conoect1 S $ - $ - $ 3,4&1,000 $ - $ - S 3A84.DOO S - S - S S $ - S $ - $ - $ $ Replace 18- - S - E S S E 3,464,000 inch Main, Key Larg. 92- $ - $ - $ 796,000 $ 620,000 S - 8 - S 1,616,000 $ - $ $ $ g - - - - $ $ $ _ $ $ _ $ _ $ _ $ _ S _ $ S $ 1,616,000 MaralhOn 18- inch rensmission Mein Replacements , S - $ - $ - $ - $ S - It 358,000 E - $ - $ - $ - S 958000 $ - $ S S $ - S _ $ - S $ $ $ 358,000 GNV3101569546.MBr062490010 1 013 ExhlbH 7 -2 2D-Year Capital Improvement Plan Costs in Inflated Dollars 1 2 3 4 5 Immediate 8 7 8 9 Mid -term 17 12 13 14 15 16 17 18 19 Lon -term Proect Name Proect 2006 2007 2008 2008 2010 2011 Subtotal 2012 2013 2014 WAS Subtotal 2017 2018 2019 2920 2021 2022 2023 2024 2026 Subtotal Total 18 -inch t Transmission Main m replaceent N. RoOSevelt Phase II S - S - S - S 1,718,000 S 1,769,000 S - E 3,487,000 3 S - $ - $ - It $ $ - $ $ - $ - $ 3 - $ $ $ $ 3,487,000 Cathodic Protection $ $ 2,182,000 1 $ - E - It - 1 $ - S 2,182,000 $ - S 5 $ $ $ S - $ - S - $ - S - S - S - $ - $ - $ $ Z182,000 J. Robert Unsize diesel Dean WfP driven pumps 1 and 2 $ - $ - $ - $ - $ 340,000 $ - ; 340 $ Is - S $ $ $ S $ - $ - S - $ - $ - E - ; - S ', S 340,000 J. Robert ean D WTP Install near 5 MG storage tank $ - E - $ - $ - 5 - $ - E - $ 5,797,000 $ - $ - S - S - $ 6,797,000 5 $ 3 $ - $ $ S S It S S 5,797,000 Key Largo Install 3rd electric Booster PS transmission pump S - $ - $ - S - $ - $ - f $ - 3 - $ $ 329000. $ 8 329,000 $ - S - $ S - $ - 3 - $ - E - $ $ '.S 329 Plantation Key Booster PS $ - $ - $ I S - $ - $ - S - S 5,026,000 $ 5,177,000 S $ S 570,20.1,000 9 $ - $ - It - $ - $ - $ - ; - $ $ S 10,203000 Marathon Pump Staaon Engine . 1075 $ S 934,000 $ $ 830.000 $ - E - $ - S - 5 - S - S is - S - $ $ $ $ Marathon Add a second 3 MG - - - - S - $ - S E 934.000 Booster storage tank E - $ - S - $ - S 1,610,000 $ 1,658,000 $ 3,266,000 5 $ - S - $ - $ - $ _ $ _ $ _ ; _ S _ $ - $ $ - 5 $. $ $ 3,268,000 Marathon booster PS Install 3rd electric PUMP $ - 8 - S - S - $ - S - $ $ - 3 $ - $ 329,000 $ - E 328,000 $ - E - 8 S - $ - S $ - 3 - $ S $ 329 Lower Keys Booster pump Station #1 It - S - $ - $ - $ - 8 - S - S - $ - 5 - it 5,492,000 3 5,657,000 $11,149,000 $ $ - $ - $ - S S - S - S - $ E $ 11,149,000 Lower Keys Booster pump is Station #2 $ - S - $ - $ - S - $ _ $ _ ; _ $ _ S _ S - S - $ S - - $ - $ - S _ $ _ S - S 7,166,000 4 7,381,000 510.x47,000 $ 14.547]IDI 000 Ramrod Booster PS S $ - $ - S - $ - $ - $ $ - $ _ $ _ $ 136,000 $ - $ 136,000 E - $ - S - S - $ - 3 5 $ $ $ $ 196 Total Proect DOaM 5 $ 7,107000 $10,671,000 E 6,022,000 $ 719000 S 1,668,000 $ 29,977,000 $11,181,000 $ 6,177,000 $ - S 6,2tI8,D011 S 6,667000 $28,301,000 E - S S S S $ '$ $ 7,166,000 E 7]81,000 S 72,726 Dist79w9on Mains $ $ Replace Old Galvanized Mains S - $ 357,000 5 - $ - $ - $ - $ 361000 $ - $ $ - $ - $ - $ S - $ $ 3 $ $ $ $ Upsize Small - - $ $ Diameter ' Maims to 4- inch a other upgrades 5 $ 1,655,000 $ 1,653,6,00 $ 1,703,000 $ 2,814,000 5 2,898,000 S 10,723000 $ 2,9&5,00) 5 3,D75,DD0 S3,167,DDD S 3,202,000 S 3,360,000 $16,849,000 S 3,461,000 53,564,000 $3,671,000 $ 3,781,000 $3,895,000 $4,012,000 Cudjoe Key 54,132,000 $ 4,256,000 S 4,3111,000 S36,156,000 3 81,728,000 Additional Disiridnion Mein Header 8 - $ 569,000 $ - S - $ - S - $ 569,DDO $ - It - S - S - $ $ $ - S $ - S - S - S - $ 569,000 Islamoretle Distribution Install distribution PS mein header $ 5 - 8 999,000 16 1,029,000 S - 3 - $ 2,028,000 $ - $ - $ - $ - $ - ; - 5 - $ 5 _ $ _ g _ ; $ $ S $ $ 2,028,000 Total DlstribWion Mains Pmect S S 2675,000 E 2,662,000 E 2,732,000 $2,876,000 $ 2,898,000 $ 73,677000 $ 2,98fi $ 3.076,000 $3167,000 S 3,262,000 $ 3,31110,0110 576,849,000 S 9,461,000 53,600,000 $3,871,000 S 5,701,000 $3,895,000 $4,012,000 $41,1132,11100 $ 0.266,000 S 4,384,000 $36,756,000 $ 00,676,009 DisMbuOon PO Stan- and Stwaga Immediate Mid -term I Lon 4enrl Ocean Rear Additional 1.0 MG store e $ 3 $ $ $ $ - E E - $ 7.058,000 $1,089,000 S - S S x,ta7,0o0 3 - 5 $ S - $ - 5 - $ $ - $ - E I S 2,147,000 New Pump Station _ Lake Surprise and 0.75 MG r Storage tank $ $ - $ - S - $ - $ - $ - $ - $ $ - $ 1,470,000 $ 1,514,000 $ 2994,000 S - $ $ - $ $ - $ - $ $ E - F S 2,984,000 Replace and Rock Harbor Upsize existing Pump Station S - $ - S - S - $ - $ - 3 $ 642,000 5 082,000 $ - $ $ $ 1.304,000 $ - $ - $ - E - 8 - 8 - $ 5 $ - $ $ 1,304,000 Rock Harbor Install 0.5 MG , swre9e Tank $ $ $ - $ - S - $ - S - $ 484,000 $ 498,000 $ - S - S - $ 982,000 S s $ S - It $ - $ - $ - $ - $ - It 982,000 Rock Harbor InstaO a third 0.5 MG Tank Mew Larger Pump $ - $ - $ - $ - S - $ - E $ - 8 - $ $ $ - $ $ - $ - $ $ 1,225,000 $ - $ - $ - $ $ $ 1,226000 .5 1225,000 Station and New Tavernier Larger Storage tank 1.0 MG) $ - $ - $ - $ - 8 1,484,000 3 1,529,000 $ 3.013,000 $ - 3 - $ $ - $ - S $ - 5 - $ S - $ - $ $ - $ $ - $ 3013,000 &inch lap and 13'1111 $ Tavernier line S $ - $ - $ - $ 86,000 $ 88,000 $ 170.000 8 - S - S 5 - $ S $ $ $ $ - $ $ - It $ - $ - S $ 174,000 Install 84nch distribution mein Tavernier header along both _ sides or US -1 w S - -_. -__- -. S 727000 $ 749 _- S 7,476,000 _._ 5 _ - __. S - $ - $ - $ - $ -__ _ $ - $ '.. 5 - S - $ - S - $ - $ $ $ _ $ 7.4 78,008 Now Pump Station Plantation Key and 1.0 MG Storage tank S 1 $ $ - 5 - It Is - I $ $ - S - $ - $ 3 f Is 1,835,000 1 $1,aw $ $ - $ $ - ; $ - S S 3,725000 $ 3,725,000 GNV31015695s8.M.Da2490010 2 IN3 Exhibit 7.2 20 -Year Cap itaI Improvement Plan Costs in Inflated Dollars 1 2 3 4 5 Irrrmadmta 6 7 8 91 10 Mid-tam 11 12 13 14 15 17 18 19 Lon -term Pro act Name Pro ect 2006 2007 2006 2009 2010 2011 Subtotal 2012 2013 2014 2015 2016 Subtotal 2017 2018 2019 2020 2021 2023 2024 2025 Subtotal Total Lower New Pump Station Metecurllbe antl and 0.5 MG 12"022 ke re Sta etank $ $ - 5 $ 5 S - $ 5 - $ $ 5 - 5 $ $ _ $1,389,000 $1.431,000 $ - $ - 3 - $ - $ - E 2,620,000 6 2,820,00D Duck New Pump Station Key/Ga say antl 0.75 MG Ke Stora etank S S. - $ - S - $ 6 - $ $ $ $ $ $ S 5 5 51,865,000 $ 1.715,000 5 $ $ 5 It 3,380,000 S 3,38D,000 Install New and Crawl Key Upgraded Pump Station $ is - $ - $ - $ 1 1 $ - 5 1,227.000 5 - S IS - 5 - $ 1 $ $ $ - $ $ - $ S - $ - S $ $ - $ 1,227,000 Install New 84nch Crawl Key tap and 84nch ( assumed) Foil Line S It - $ - S - E 123,000 E - $ 123,000 $ $ S $ $ $ $ $ $ $ 5 $ - $ $ $ f $ 123,000 Replace and Crawl Key Upsize Storage Tank (to 1 MG) $ $ $ - $ - $ $ - S $ 5 $ $ $ 1,967,000 $ 1,967,000 5 $ S S 3 S $ S $ S $ 1,967,000 Vary Cut Insist New 0.5 MG Storage Tank $ $ $ - S. - $ 5 939,000 $ 939,000 $ $ E 5 $ $ S 3 $ $ E $ $ E $ $ $ 939,000 Demolish Existing 0.5 M 3 Storage Vacs Cut Tank antl Install New 0.5 MG Storage Tank $ $ $ $ - $ $ - $ $ s $ s 5 1,188,000 f 1,168,000 5 $ $ $ E Is $ s $ $ $ 1,186,000 69m Street 1 $ - $ - $ - s - $ $ - $ F $ $ $ $ $ F - $ - $ $ E - $ - $ - s $ f F 33rd Street Replace Existing Pump Station 5 _ $ - 5 - $ - S _ S - f _ $ 1359 ODD $ $ S _ $ _ $ 1,359,000 6 _ 6 _ $ _ $ _ $ _ a _ $ _ $ _ $ _ _ $ $ 1,359,000 Replace Existing 33th Street 0,5 MG Storage Tank with New 0.5 MG storage tank $ 5 S 5 s 5 $ $ $ $ $ - $ - $ $ - $ - $ - S - $1.397,000 $ - $ - $ - $ - $ 1,397,000 $ 1,397,000 New Pump Station Ramrod and 0.50 MG Storage Tank 6 - 6 - E - 6 - $ - $ - $ - $ - E - 5 - s - 5 - $ $ 2,630,000 $ - $ - $ - $ - $ - $ - $ - S 5 2,8,000 S 2,630,000 30 New Pump station Cuclae Key and 1.OMG Storage Tank is - $ 1,80,0001$ - $ - $ - $ - S 1,803,000 $ - $ S - $ E $ $ - It $ E - $ - $ E - $ $ S $ 1,803,000 Replace Pump Summeriand Station and Storage Key tank, New 0.5 MG tank $ 6 - 5 - $ - $ $ - $ $ $ $ S $ $ $ 2,674,000 $ $ $ $ $ $ $ $ $ 2,674,000 $ 2,674,0DO New Pump Station Lower Storage Tank, I. Sugarloaf New New 0.5 MG tank $ - $ - $ - $ - $ - $ - f $ - $ It - F - $ $ It $ $ - $2 $ - $ - s - S f 2,960,000 $ 2,960,000 Stock Island Replace Existing Distribution Pump Station S $ $ $ E $ $ $ 2,472,000 S $ $ $ S 2,472.000 $ $ $ $ S $ $ $ $ $ 6 2,472,000 Total Distibutim Pump Station $ $ 1,803,000 S f $ 3,647,000 $ 3,305,000 S 8,766,000 S 4,967,000 $ 2,218,000 $1,089,000 $ 1,470,000 $ 4,649,000 $14,383,000 $ 7,139,000 $3,279,000 $3,098,000 $ 2,940,000 $4,357,000 $ $ $ $ $20,811,000 $ 43,949,000 F6c➢9ie11; Wd stuemro $ Desal Sewall Rapsin 3073 $ $ 773,000 $ 3,A48,ODD $ - $ - s - $ 4,221,000 E - S $ - S $ f $ $ - $ $ $ - $ - $ - 3 - $ $ S 4 New Admin Bld era a 3081 6 - 6 412,000 Is 3,007;000 S 3,715,000 $ - s - $ 7,734,000 $ - E - S - E S - S - $ S 6 - 6 $ - $ - $ $ _ $ - - $ S 7,734,1300 Marathon Cenval Warehouse 3077 $ - $ - $ - $ - 5 $ - $ $ $ - E - $ - $ $ - $ $ - $ - $ - $ $ $ - - DESAL Customer Service/REcor ds Bldg 3091 $ _ $ 438000 , $ 451000 , $ - $ _ $ BBB, 000 $ 889000 $ $ _ $ $ _ E $ $ _ $ _ $ _ $ _ $ _ $ _ $ _ It _ $ _ $ $ 889,000 DESAUJStock Island/Lower Keys Garage Wastewater 3083 $ _ $ 206,000 E _ $ - $ _ $ _ $ 206000 , $ $ _ $ $ _ $ _ $ $ _ $ _ $ _ $ _ $ _ $ _ $ _ $ _ S _ S _ S 205,0DO Marathon Customer Senioe Center 3077 E Is 309,000 $ 1,051,000 $ 1;803,000 $ 15 - $ 3,173,000 $ $ $ $ $ $ $ $ $ $ $ S $ $ $ $ $ 3,173,000 Total Pro ect Costs $ $ 2,1311 E 6,1167,000 S 5,610,000 f S S 18,228000 S E $ $ $ $ $ $ E $ It E S S S $ $ 16,223,000 All Project Cos4Includes FacllM 18,843,000 48,767,000 36,566,000 10,180,000 f 7,861,000 $121,216,000 119,123,000 515,699,000 54,2 000 $11,018,000 513,866,000 $63,762000 $10,600,000 $6.11143.660 $6,767,000 E 8,721,000 $8,252,000 4,012000 (4132,000 $11,422,000 $11,765,000 $70,514,000 $255,492,000 Note: Pm eded Caste assume annual inflation 3.00% GNV3101569548.xIs1082490010 3 m 3 Exhibit 7 -2 (continued) vvaier zniu Total Consulting, Construction C Total Project Suggested Project ' Construction Administrative Contingency Cost Cost' , Legal Feesb Cost Timing J. Robert Dean WTP Phase I and Phase II RO Facility, Floridan Wells Construction Cost Floridan Water Supply Well - Phase 14.5MGD WTP - Three 2mgd wells and one standby $ 5,913,044 $ 5,913,044 $ 1,182,609 $ 1,064,348 $ 8,160,000 2007 -2009 Floridan Water Supply Well - Phase II adding 1.5MGD for a total of 6MGD WTP - One additional 2mgd well $ 1,750,000 $ 1,750,000 $ 350,000 $ 315,000 $ 2,415,000 2013 ASR (Cost per FKAA for FY 2007 only) $ 1,000,000 $ 1,000,000 $ 1,000,000 2007 Notes: 'These are order -of- magnitude cost opinions (in April 2006 dollars) made without detailed engineering design. It is normally expected that estimates of this type are accurate within -30% to +50 %. b Consulting, administrative, legal fees equal 20 percent of construction cost. ° Contingency (15 percent of subtotal costs for all items). GNV3101569546.xls/062490010 1 of 1 Exhibit 7 -2 (cont.) Water Treatment Plant Project Construction Total Total Project Suggested Construction Remarks Cost' Cost' Cost Timing J. Robert Dean WTP Phase I and Phase II RO Facility Construction Cost Option (Phase 1 based on 60% design cost estimate and Phase 2 based on 60% estimate line Item cost) PHASE I- 4.5MGD RO Piping and Electrical to supply wells and concentrate injection well $ 1,829,721 $ 1,829,721 $ 1,829,721 2007 -2009 PHASE I- 4.5MGD RO membrane system $ 5,439,072 $ 5,439,072 $ 5,439,072 2007 -2009 PHASE I- 4.5MGD RO Degasifier /Scrubber system $ 1,248,204 $ 1,248,204 $ 1,248,204 2007 -2009 PHASE I- 4.5MGD RO Product transfer pump station $ 3,123,766 $ 3,123,766 $ 3,123,766 2007 -2009 PHASE I- 4.5MGD RO Chemical storage and feed system $ 760,706 $ 760,706 $ 760,706 2007 -2009 PHASE I- 4.5MGD RO Site work $ 795,946 $ 795,946 $ 795,946 2007 -2009 PHASE I- 4.5MGD RO Yard piping $ 1,026,337 $ 1,026,337 $ 1,026,337 2007 -2009 PHASE I- 4.5MGD RO Electrical and I &C $ 1,863,390 $ 1,863,390 $ 1,863,390 2007 -2009 PHASE I- 4.5MGD RO Building $ 2,236,257 $ 2,236,257 $ 2,236,257 2007 -2009 PHASE I - One Concentrate Disposal DIW 1 $ 6,900,000 $ 6,900,000 $ 6,900,000 2007 -2009 PHASE II - 1.5MGD ADDITION (TOTAL 6.OMGD RO) RO membrane system $ 1,290,000 $ 1,290,000 $ 1,290,000 2013 PHASE II - 1.5MGD ADDITION (TOTAL 6.OMGD RO) Well pipinig, pump, electrical $ 546,400 $ 546,400 $ 546,400 2013 PHASE II - 1.5MGD ADDITION (TOTAL 6.OMGD RO) Site work $ - $ $ - 2013 PHASE II - 1.5MGD ADDITION (TOTAL 6.OMGD RO) Yard piping $ $ $ 2013 PHASE II - 1.5MGD ADDITION (TOTAL 6.OMGD RO) Yard electrical $ $ $ 2013 PHASE II - 1.5MGD ADDITION (TOTAL 6.OMGD RO) Plant computer system and programm $ $ $ 2013 Project Total $27,059,799 $27,059,799 27,059,799 Kermit H. Lewin RO Desalination WTP Membrane Replacement and Plant Upgrades, Stock Island, Construction Cost Option (Based on 60% Design Cost Estimate) CO2 pretreatment storage and feed system $ 826,851 $ 826,851 $ 826,851 2007 -2009 Elevated walkway and platform $ 143,403 $ 143,403 $ 143,403 2007 -2009 14" Auger cast piles $ 88,532 $ 88,532 $ 88,532 2007 -2009 Clearwell rehabilitation $ 37,898 $ 37,898 $ 37,898 2007 -2009 Relocate injection well piping $ 16,788 $ 16,788 $ 16,788 2007 -2009 RO train piping upgrade $ 1,379;755 $ 1,379,755 $ 1,379,755 2007 -2009 Electrical and I &C $ 66,839 $ 66,839 $ 66,839 2007 -2009 Toyobo RO membrane /pressure vessels $ 1,257,500 $ 1,257,500 $ 1,257,500 2007 -2009 Project Total $ 3,817,566 $ 3,817,566 $ 3,817,566 Marathon RO Desalination WTP Membrane Replacement and Plant Upgrades, Marathon, Construction Cost Option (Based on Stock Island 60% line item estimate) CO2 pretreatment storage and feed system $ 413,400 $ 413,400 $ 413,400 2007 -2009 14" Auger cast piles $ 88,000 $ 88,000 $ 88,000 2007 -2009 RO train piping upgrade $ 689,900 $ 689,900 $ 689,900 2007 -2009 Elevated walkway and platform $ 143,403 $ 143,403 $ 143,403 2007 -2009 Electrical and I &C $ 66,800 $ 66,800 $ 66,800 2007 -2009 Toyobo RO membrane /pressure vessels $ 1,257,500 $ 1,257,500 $ 1,257,500 2007 -2009 Project Total $ 2,659,003 $ 2,659,003 2,659,003 OCEAN REEF 1.5MGD NEW RO WT $ 8,350,000 $ 8,350,000 $ 8,350,000 2007 -2009 Grand Total $ 41,886,368 Notes: 'Standby DIW not required since FKAA has flexibility to perform the 5 year MIT during the wet season and can shut down the RO WTP during that time Cost provided by FKAA GNV3101569546.xis/062490010 1 of 1 Exhibit 7 -2 (cont.) Construction and Total Proiect Cost Estimates for ProDosed Transmission Main Improvement Proiects J. Robert Dean WTP Pipeline Upsize diesel driven pumps 1 and 2 218840.5 218840.5 $43,768 $39,391 $302,000 FY2010 Total Consulting, 3518116 3518116 $703,623 $633,261 $4,855,000 At FKAA discretion Construction Construction Administrative, Total Project $0 Project Size (inches) Size (inches) Cost' Cost' Legal Fees Contingency` Cost Suggested Timing Remarks Replace 36 -inch Transmission Main 182500 182500 $36,500 $32,850 $251,850 At FKAA discretion (maintenance) Jewfish Creek $0 $0 $0 At FKAA discretion Implementation at the end of master plan Paint exterior of 5MG concrete tank FY2008 Contingency, only needed if construction planning period. Depends on results of (maintenance) 6100000 $6,100,000 $0 $0 costs exceed funds in JPA C -111, Protect 36 -inch Key Largo Booster PS $0 With elimination of C -111 Canal Bridge 182500 $182,500 dictate (maintenance) FOOT owes money to FKAA Other 18 -mile stretch segments, Protect $32,850 $ 144,928 $ 144,928 $28986 $26087 $200000 FY2008/2009 For protection of transmission main during 36 -inch On line by 2011 Lower Keys Booster Pump Station #2 6100000 $6,100,000 , , , highway construction MM 93 -98" 36 21,120 $ 13,662,000 $ 13,662,000 FY2007 and 2008 delayed, property acquisition and design $13,662,000 Replace Other Transmission Mains should begin immediately GNV3101569546.xis/062490010 12 -inch Ocean Reef Transmission Main 12 22,000 $2,310,145 $2,310,145 $462,029 $415,826 $3,188,000 At FKAA discretion Worst segments done first Replace 18 -inch Main, Key Largo MM $ 1,086,957 $ 1,086,957 92 -93° 18 1,400 $217,391 $195,652 $1,500,000 Marathon 18- inch Main Replacements 18 1,000 $ 217,391 $ 217,391 $43,478 $39,130 $300,000 18 -inch Main Replacement, N. 18 15,500 $ 2,278,261 $ 2,278,261 $455,652 $410,087 $3,144,000 Roosevelt Phase II Cathodic Protection $ 1,613,696 $ 1,613,696 $228,334 $276,304 $2,118,334 FY2006/2007 Based on bid price and contingency allowance (includes engineering SDC) J. Robert Dean WTP Upsize diesel driven pumps 1 and 2 218840.5 218840.5 $43,768 $39,391 $302,000 FY2010 Ready to go out to bid Install new 5MG storage tank 3518116 3518116 $703,623 $633,261 $4,855,000 At FKAA discretion Paint interior of 1 MG steel tank $0 $0 $0 FY2007 (maintenance) 2073188.5 2073188.5 $0 $0 $0 FY2007 Paint exterior of IMG concrete tank 182500 182500 $36,500 $32,850 $251,850 At FKAA discretion (maintenance) $0 $0 $0 At FKAA discretion Implementation at the end of master plan Paint exterior of 5MG concrete tank planning period. Depends on results of (maintenance) 6100000 $6,100,000 $0 $0 $0 At FKAA discretion transmission system hydraulic evaluation Key Largo Booster PS and what increasing water demands Install 3rd electric transmission pump 182500 $182,500 dictate (maintenance) $36,500 $32,850 $251,850 At FKAA discreticn Implementation at the end of master plan Plantation Key Booster PS 6100000 $6,100,000 $1,220,000 $1,098,000 $8,418,000 FY2010 and 2011 On line by 2011 Lower Keys Booster Pump Station #2 6100000 $6,100,000 $1,220,000 $1,098,000 $8,418,000 At FKAA discretion If 36" at MM 93 -97 replacement is FY2007 and 2008 delayed, property acquisition and design should begin immediately Marathon Booster PS Engine & Pumps 1075 657246.5 657246.5 $131,449 $118,304 $907,000 FY2006 and 2007 Ready to go out to bid Repairs to 3MG tank exterior 0 0 (maintenance) $0 $0 $0 FY2007 Add a second 3MG storage tank 2073188.5 2073188.5 $414,638 $373,174 $2,861,000 At FKAA discretion Install 3rd electric pump (maintenance) 182500 182500 $36,500 $32,850 $251,850 At FKAA discretion Implementation at the end of master plan planning period. Depends on results of Lower Keys Booster Pump Station #1 6100000 $6,100,000 $1,220,000 $1,098,000 $8,418,000 At FKAA discretion transmission system hydraulic evaluation and what increasing water demands dictate Implementation at the end of master plan planning period. Depends on results of Lower Keys Booster Pump Station #2 6100000 $6,100,000 $1,220,000 $1,098,000 $8,418,000 At FKAA discretion transmission system hydraulic evaluation and what increasing water demands dictate GNV3101569546.xis/062490010 1 of 2 Exhibit 7 -2 (cont.) Construction and Total Proiect Cost Estimates for Proposed Transmission Main Improvement Proiects Pipeline Construction Project Size (inches) Size (inches) Cost' Total Construction Cost' Consulting, Administrative, Legal Fees Contingency` Total Project Cost Suggested Timing Remarks 75362 75362 Implementation at the end of master plan planning period. Depends on results of Ramrod Booster PS $15,072 $13,565 $104,000 At FKAA discretion transmission system hydraulic evaluation and what increasing water demands dictate Transmission SCADA Upgrade 0 0 $0 $0 At FKAA discretion Being implemented Project Total $58,899,034 Notes: 'These are order -of- magnitude cost opinions (in April 2006 dollars) made without detailed engineering design. It is normally expected that estimates of this type are accurate within -30% to +50% 'Consulting, administrative, legal fees equal 20 percent of construction cost. `Contingency (15 percent of subtotal costs for all items). ° Construction Cost from Exhibit D -2, with 20 percent contingency removed from that estimate. 'Unit Price Construction Cost from Exhibit D -1, with 20 percent contingency removed from that estimate. GNV3101569546.xis/062490010 2 of 2 Exhibit 7 -2 (cont.) Construction and Total Proiect Cost Estimates for Proposed Distribution Pipeline Improvements Pipeline P Construction Project Construction 4 Administrative, Contingency Total Project Suggested Remarks Size (inches) Length (foot) Cost Cost � Legal Feas Timing Replace Old Galvanized Mains 4 400 $23,102 $247,102 $49,420 $44,478 $341,000 FY 2006/2007 Part of $2.5 million annual allocation for 6 3,200 $224,000 distribution upgrades Subtotal $341,000 Upsize Small- Diameter Mains to 4- 4 369,900 $32,408,696 $32,408,696 $6,481,739 $5,833,565 $44,724,000 At FKAA At $2.5 million per year, will take 11 years inch discretion to replace all pipe Subtotal $44,724,000 Cudjoe Key Additional Distribution 8 6000 $400000 $400000 $80000 $72000 $552000 At FKAA Part of $2.5 million annual allocation for Main Header , , , , , discretion distribution upgrades Subtotal $552,000 Tavernier Pump Station New Dedicated 6 -inch tap and 8 -inch Fill 6 -inch Tap -- -- FY 2007/2008 8 -Inch Fill Line 8 900 $0 $0 $0 Part of Tavernier pump station improvements Install 8 -inch distribution main header At FKAA along both sides of US 1, where 8 12,000 $0 $0 $0 discretion Part of Tavernier Pump Station required Improvements Subtotal $o Islamorada Distribution PS Install distribution main header 8 17,500 $ 1,364,493 $ 1,364,493 $272,899 $245,609 $1,883,000 At FKAA Part of $2.5 million annual allocation for discretion distribution upgrades Subtotal $1,883,000 Crawl Key Install New 6 -inch tap and 8 -inch (assumed) Fill Line 6 -inch Tap 8 -inch Fill Line B 500 $0 $0 $0 At FKAA discretior Installed when pump station installed Subtotal $0 Project Total $47 ,500,001 Notes: 'Pipeline costs are estimated in Appendix E as follows: 4- inch= $58 /LF, 6- inch= $70 /LF, 8- inch= $78 /LF, 10- inch= $95 /LF, 12 -inch= $105 1LF 'These are order -of- magnitude cost opinions (in April 2006 dollars) made without detailed engineering design. It is normally expected that estimates of this type are accurate within -30% to +50 'Consulting, administrative, legal fees equal 20 percent of construction cost. ° Contingency (15 percent of subtotal costs for all items). GNV3101569546.xis I oil Exhibit 7 -2 (cont.) Construction a T otal Project Cost Estimates of Proposed Distribution Pump Station System Improvements and for Proposed New Distribution Pumo Station Systems Distribution Pump Pump Station Ground Storage Tank Total Consulting, Total Project Station System Construction Cost Construction Cost ' Construction Administrative, Contingency 3 Suggested Timing and Remarks Cost $1,910,870 $382,174 $343,957 Cost' Legal Fees' 110144.6 $110,145 Ocean Reef $19,826 $152,000 Additional 1.0 MG Storage Requires demolition of existing pump $1,246,377 $1,246,377 $249,275 $224,348 $1,720,000 If space is available with RO WTP Permanent Standby Power (included in RO WTP) along both sides of US -1 where required included in RO WTP construction begins. As soon as possible; Subtotal $1,720,000 Lake Surprise Subtotal $4,081,000 Plantation Key New Pump Station and 0.75 MG Storage Tank $1,632,609 $0 $1,632,609 $326,522 $293,870 $2,253,000 Implemented at FKAA's discretion P $1,921,015 $384,203 $345,783 $2,651,000 Implemented at FKAA's discretion p Subtotal $2,253,000 Rock Harbor Subtotal $2,651,000 Lower Matecumbe Key Replace and Upsize Existing Pump New Pump Station and 0.5 MG Storage $1,412,319 Tank $1,412,319 $282,464 Assumes maintenance functions will be Station $779,710 $779,710 $155,942 $140,348 $1,076,000 relocated and site will be dedicated to Duck Key /Grassy Key distribution pump station system Install 0.5 MG Storage Tank $ 586,957 $586,957 $117,391 $105,652 $810,000 Within next 5 years Repaint Tank Exterior maintenance p (maintenance) -_ $295,696 $0 $0 $0 As corrosion of exterior dictates, probably $0 Subtotal $2,267,000 within 5-10 years Install a Third 0.5 MG Tank $ 586,957 $586,957 $117,391 $105,652 $810,000 Monitor need for a third 0.5 MG tank; likely will be at and of planning period Subtotal $2,696,000 Tavernier New Larger Pump Station and New Larger Storage Tank (1.0 MG) 1910869.5 $1,910,870 $382,174 $343,957 $2,637,000 6 -inch tap and 8" fill line 110144.6 $110,145 $22,029 $19,826 $152,000 Requires demolition of existing pump Install 8 -inch distribution main header $936,232 $936,232 $187,246 $168,522 station and storage tank before $1,292,000 along both sides of US -1 where required construction begins. As soon as possible; definitely within the next 5 years. Subtotal $4,081,000 Plantation Key New Pump Station and 1.0 MG Storage Tank $1,921,015 $1,921,015 $384,203 $345,783 $2,651,000 Implemented at FKAA's discretion p Subtotal $2,651,000 Lower Matecumbe Key New Pump Station and 0.5 MG Storage $1,412,319 Tank $1,412,319 $282,464 $254,217 $1,949,000 Implemented at FKAA's discretion Subtotal $1,948,000 Duck Key /Grassy Key New Pump Station and 0.75 MG Storage Tank $1,642,754 $1,642,754 $328,551 $295,696 $2,267,000 Implemented at FKAA's discretion Subtotal $2,267,000 GNV3101569546.xis/062490010 1 of 3 Exhibit 7 -2 (cont.) Construction and Total Project Cost Estimates of Proposed Distribution Pump Station System Improvements and for PfoDosed New Distribution Pumo Station Systems Distribution Pump Pump Station Ground Storage Tank Total Consulting , Total Project Station System Construction Cost Construction Cost ' Construction Administrative, Contingency a Suggested Timing and Remarks Cost Cost' Legal Fees' Crawl Key Assumes adjacent property could not be Install New and Upgraded Pump Station 789855 $789,855 $157,971 $142,174 $1,090,000 purchased. As soon as possible, within next 5 years. Repaint Existing Exterior Storage Tank $78,986 $78,986 $15,797 $14,217 $109,000 Probably within the next 5-7 years (Maintenance) Replace and Upsize Storage Tank (to Assumes tank replacement will occur 1 MG) . $1,060,870 $1,060,870 $212,174 $190,957 $1,464,000 when existing tank needs replaced. (Estimate between 10-15 years.) Subtotal $2,663,000 Vaca Cut Install New 0.5 MG Storage Tank $586,957 $586,957 $117,391 $105,652 $810,000 Begin immediately Demolish Existing 0.5 MG Storage Tank Assumes existing tank will be used until and Install New 0.5 MG Storage Tank $629,710 $629,710 $125,942 $113,348 $869,000 about end of useful life, probably within the next 7- 10 years Subtotal $1,679,000 No capital costs; assumes facility will be 69"' Street $824,638 $824,638 $164,928 $148,435 $1,138,000 abandoned when existing tank needs painting 33`" Street $650,000 $650,000 $130,000 $117,000 $897,000 Replace when pump station cannot meet demands (assumed to be within the next Replace Existing Pump Station -- $0 $0 $0 4-7 years). Proposed new 3 MG storage tank proposed under transmission will accommodate additional distribution storage requirements. Paint Existing 0.5 MG Storage Tank $0 $0 $0 $0 When corrosion dictates, probably within 7- Exterior (maintenance) 12 years When tank has reached its useful life Replace Existing 0.5 MG Storage Tank $0 $0 $0 $0 (estimated to be within next 15 -20 years). with New 0.5 MG Storage Tank Requires demolition of existing storage tank. Subtotal $3,714,000 Ramrod New Pump Station and 0.5 MG Storage $ 1,376,812 $1,376,812 $275,362 $247,826 $1,900,000 Longer term improvement. Implemented at Tank FKAA's discretion Subtotal $1,900,000 GNV3101569546.xis/062490010 2 of 3 Exhibit 7 -2 (cont.) Construction and Total Project Cost Estimates of Proposed Distribution Pu mp Station System Improvements and for Proposed New Distribution Pump Station Svstems Distribution Pump Pump Station Ground Storage Tank Station System , ' Construction Cost Construction Cost Total Construction Cost' Consulting , Administrative, Legal Fees Contingency � Total Protect Suggested Timing and Remarks Cost Summerland Key Assumes FKAA adjacent property has Replace Pump Station and Storage wetlands; must build on existing site. Tank, New 0.5 MG Tank $1,400,000 $1,400,000 $280,000 $252,000 $1,932,000 Demolition of pump station and storage tank required. Implemented at FKAA's discretion Subtotal $1,932,000 Cudjoe Key (4) New Pump Station and 1.0 MG Storage $1,268,116 $1,268,116 $253,623 $228,261 Longer term improvement. Implemented at $1,750,000 Tank (under design) FKAA's discretion Subtotal $1,750,000 Lower Sugarloaf New Pump Station and 0.5 MG Storage $1,376,812 $1,376,812 $275,362 $247,826 Longer term improvement. Implemented at $1,900,000 Tank FKAA's discretion Subtotal $1,800,000 Stock Island Distribution Replace Existing Pump Station Replace when deteriorating conditions of $1,500,000 $1,500,000 $300,000 $270,000 $2,070,000 existing structure dictate, and Records Storage Building is abandoned Subtotal $2,070,000 Project Total $33,546,000 Notes: 'Land acquisition costs are not included in these are order -of- magnitude cost opinions (in April 2006 dollars), which were made without detailed engineering design. It is normally expected that estimates of this type Consulting, administrative, legal fees equal 20 percent of construction cost. 3 Contingency (15 percent of subtotal costs for all items). 4. From Bond Report. GNV3101569546.xls1062490010 3 of 3 SECT 7. CAPITAL IMPROVEMENT PROGRAM Project cost estimates reflect April 2006 costs (Engineering News Record Construction Cost Index of 7,695). Actual costs for any given project would depend on multiple factors, including, but not limited to, actual material and market costs, competitive market conditions, final project scope, implementation schedule, and other variable factors. As FKAA is aware from recent construction projects, prices are also highly subject to variation as a result of shortages resulting from recent natural disasters. As a result, the final project costs will vary from the estimates presented herein. Because of such factors as limited labor force, high cost of housing, and high cost of goods and services, Keys construction costs are greater than costs for comparable work on the mainland of South Florida. Generally, a 20 percent "Keys Factor' is added to Keys construction cost estimates to account for the Keys market conditions. Wherever possible, actual construction prices recently received by FKAA for different types of work (that is, distribution system pipelines, distribution pump stations, storage tank painting) have been used to develop cost estimates for this Master Plan, adjusted to April 2006 costs, where noted. These costs already account for Keys market conditions and generally provide the most accurate cost estimates at this planning stage when only a conceptual design is available. Where actual construction prices for similar types of recent work are not available, standard estimating procedures are used to estimate construction costs. Other costs, such as consulting and engineering inspection, administration, legal, and financing, are part of any project and must be included with construction costs, so that all capital improvement costs are accounted for. For this Master Plan, these other project costs are estimated as follows: An amount of 20 percent of the construction cost was used for consulting and engineering inspection, administration, legal, and financing. • A contingency of 15 percent of the subtotal of construction cost and the 20 percent cost above was also included as part of the other project costs. Total project costs are the total of the construction cost and the other project costs. All capital improvement costs addressed in this Master Plan are total project costs, unless otherwise indicated. Estimated project costs for all proposed water system capital improvements are sum- marized in Exhibit 7 -2. The basis for estimating detailed construction costs and total project costs for specific projects is provided in the respective sections of this Master Plan. WP8310127161224.DOC/061640010 7-18 WB122005005DFB AMY NEAVILIN, CPA CLERK OF CIRCUIT COURT & COMPTROLLER MOMM CNK" nffi A May 21, 2016 Mr. Ernest L. Reddick, Program Administrator Administrative Code & Weekly R.A. Gray Building 500 S Bronough Street Tallahassee FL 32399 -0250 Dear Mr. Reddick, Enclosed please find a certified copy of Ordinance No. 007 -2016 A public hearing to consider adoption of an ordinance by the Monroe County Board of County Commissioners amending the Monroe County Comprehensive Plan, adopting the 10 -Year Water Supply Plan Update to be consistent with the South Florida Water Management District Lower East Coast Water Supply Plan Update of 2013. (Legislative Proceeding). This Ordinance was adopted by the Monroe County Board of County Commissioners at a Special Meeting, held in formal session, on April 13, 2016. Please file for the record. Should you have any questions please feel free to contact me at (305) 295 -3130. Respectfully ubmitt d, I y 4avilin, � � CPA, Clerk of the Circuit Court and ex officio Clerk of the Board of County Commissioners by: Cheryl Robertson, D.C. cc: County Attorney via e -mail Growth Management via e-mail County Administrator via e-mail BOCC via e -mail MuniCode via e-mail File 500 Whitehead Street Suite 101, PO Box 1980, Key West FL 33040 Phone: 305 - 295 -3130 Fax. 305- 295 -3663 3117 Overseas Highway, Marathon, FL 33050 Phone: 305 - 289 -6027 Fax: 305 - 289 -6025 88820 Overseas Highway, Plantation Key, FL 33070 Phone: 852 -7145 Fax: 305 - 852 -7146 'Oa 1VE t� FLORIDA DEPARTMENT 0 STATE RICK SCOTT Governor May 23, 2016 Honorable Amy Heavilin Clerk of the Circuit Court Monroe County 500 Whitehead Street, Suite 101 Key West, Florida 33040 Attention: Ms. Cheryl Robertson, Executive Aide Dear Ms. Heavilin: KEN DETZNER Secretary of State Pursuant to the provisions of Section 125.66, Florida Statutes, this will acknowledge receipt of your electronic copy of Monroe County Ordinance No. 007 -2016, which was filed in this office on May 23, 2016. Sincerely, Ernest L. Reddick Program Administrator ELR/lb R. A. Gray Building • 500 South Bronough Street • Tallahassee, Florida 32399 -0250 Telephone: (850) 245 -6270 www.dos.state.fl.us