Loading...
Item C12BOARD OF COUNTY COMMISSIONERS AGENDA ITEM SUMMARY Meeting Date: 1/16/14 Division: Public Works Bulk Item: Yes X No Department: Solid Waste/Hazardous Waste Staff Contact: Rosa Washimaotr/292-4432 AGENDA ITEM WORDING: Approval from Monroe County Board of County Commissioners for staff to negotiate an agreement with Seatech, Inc. of the Florida Keys, for Two (2) Hazardous Material Prefabricated Storage Sheds, as replacement to the sheds located at the Long Key and Cudjoe Transfer Stations. If agreement is not attained, then provide approval to advertise and rebid the project. ITEM BACKGROUND: On December 3, 2013, one bid was received for Two (2) Hazardous Material Prefabricated Storage Sheds, as replacement for the twenty (20) plus years old sheds located at the Long Key and Cudjoe Transfer Stations. Seatech, Inc. of the Florida Keys was the low bidder. The bid amount is within the budgeted amount for the project. PREVIOUS RELEVANT BOCC ACTION: This project is included and identified within Monroe County's Capital Improvement Plan, approved by the MCBOCC in September 2013. CONTRACT/AGREEMENT CHANGES: N/A STAFF RECOMMENDATIONS: Approval TOTAL COST: N/A INDIRECT COST: N/A BUDGETED: Yes X No COST TO COUNTY: Approx.. N/A SOURCE OF FUNDS: REVENUE PRODUCING: Yes No X AMOUNT PER YEAR: N/A APPROVED BY: County Atty OMB/Purchasing Risk Management N/A DOCUMENTATION: DISPOSITION: Revised 11/06 Included X Not Required AGENDA ITEM # Was hin ton -Rosa From: Washington -Rosa Sent: Friday, December 13, 2013 12:14 PM To: Wilson -Kevin Cc: Grant -Bill; Basham-Michael Subject: Hazardous Waste Sheds for Transfer Stations Attachments: 2013-12-13 114630.pdf; 2013-12-13 114653.pdf MEMORANDUM DATE: December 13, 2013 TO: Kevin Wilson, Public Works & Engineering Division FROM: Rosa S. Washington, Sr. Solid Waste Administrator RE: Bid for Two (2) Hazardous Material Prefabricated Storage Sheds, as replacement to the sheds located at the Long Key and Cudjoe Transfer Stations Though there were numerous inquiries regarding this bid, only one bid was received for the project. Seatech, Inc. of the Florida Keys, a local Company located in Summerland Key, was the only bidder with a bid amount of $249,445, which is within budget. Companies from the mainland that showed interest in the project were concerned about the costs of transportation to bring materials in and out of Monroe County. They also expressed concern about the cost of lodging employees that would assemble the sheds at their final destination. Attached please find the Bid Tabulation Sheet and detailed pricing summary. In reviewing Seatech's bid, we found that they understand the purpose of the sheds, the County's commitment to purchasing quality/durable products, and providing a safe/healthy environment for its employees and residents that visit the transfer stations daily. The County's current sheds are over 21 years old, rusted, roof leaking, have been patched numerous times and need to be preplaced at soon as possible. Seatech's bid is within budget and offer the County a product that will serve it as well as our current sheds have. However, we would like to move forward by negotiating with the vendor to secure the best labor costs and materials pricing for Monroe County. At the January 16, 2014, BOCC meeting we will be requesting the BOCC's authorization to negotiate with the vendor. We will also request permission to re -advertise if an agreement is not reached. If you have any further questions or need more information, please do not hesitate to call or e-mail me. Thanks, Rosa S. Washington Senior Solid Waste Administrator Monroe County Public Works Division Historic Gato Building 1100 Simonton St., Rm. 2-231 Key West, FI. 33040 2 (305) 292-4432 Cell: (305) 797-2136 d s } _c a d d� s � u a Ln d € -LU ry s° c a oa d ® Z +n b u F- z } } F" D 0 Q Ilu 'd LU ~ m U U ° L `-� — 3 } c ; UZ T M Y m ul0. d Z so c } w 9 ® N �.J 1�1 U Z f O N u fa co 4- ® a m 4 Mn S L CL o � � d L 0� U � 7 w Z y N s i ® d V L oil A 4} L ca d u L O L3 In ia9 ledrech int OF THE FLORIDA KEYS MW DESIGN BUILD CONTRACTORS Long Key Landfill Material Labor Engineering, Permitting $6,300 Demo Existing $ $6,820 Deliver, off-loading, installation and set-up of Hazardous Material Prefabricated Steel Storage Shed $73,648 $12,100 12'x24' Marana Shelter, Freight & Installation of Shade Structure $19,834 $6,628 Subtotal $93,482 $31,848 TOTAL $125,330 Cuqooe Landfill - -- Material Labor En ineerin , Permittin $6,300 Demo Existing $ $6,315 Deliver, off-loading, installation and set-up of Hazardous Material Prefabricated Steel Storage Shed $73,648 -__ _$11 ,390 12'x24' Marana Shelter, Frei ht &Installation of Shade_S_tructure $19,834 $6,628 Subtotal $93,482 1 $30,633 TOTAL - 12115 *Note - The above pricing is utilizing the existing concrete slabs, if any alterations are needed there will be additional costs. It also includes utilizing existing electrical service located at the site location. The above pricing also includes the Hazardous Material prefabricated steel storage sheds and the metal shade structures specified, within this proposal. "FS" Series A free-standing, relocatable chemical storage and containment structure. The structure includes the following components for storage of flammable or combustible liquids and other hazardous materials. STANDARD FEATURES: • Factory Mutual System ("FM") Approved & Labeled. • Exterior Wall Construction: Weatherproof 2-hour fire -rated noncombustible construction, with multiple layers of UL Classified fire -resistive gypsum wallboard encased between interior galvannealed steel sheets & exterior welded heavy gauge steel sheets for maximum durability, weather resistance & rigidity. Gypsum wallboard layers are offset with overlapping joints for maximum fire -resistance. • Sump Wall Construction: Weatherproof 2-hour fire -rated noncombustible construction, same as exterior walls, utilizing interior & exterior continuously welded heavy gauge steel sheets for maximum spill containment protection. • Roof/Ceiling Construction: Weatherproof 2-hour fire -rated noncombustible construction, same as exterior walls, utilizing interior galvannealed steel sheets & continuously welded heavy gauge steel roof sheets for maximum durability and weather resistance. Roof/ceiling permanently attached to exterior walls. • 60"W x 80"H, Three-hour fire -rated double door(s), UL Classified & Labeled, equipped with UL Listed self-closer(s) and UL Listed exterior security lock(s) with keyless interior safety release lever(s). • Screened Air Vent(s): Air inlet vent(s) equipped with UL Classified & Labeled 3-hour rated fire dampers with louvers & screens to provide air flow. Dampers have a galvanized steel frame, curtain -type galvanized steel blades, and a UL Listed 1650F fusible link. • Building Base: Open channel construction for forklift and/or crane slings and under building inspections. • Internal Spill Containment Capacity: Minimum 30% of total storage capacity. Surpasses regulatory and Factory Mutual requirements for spill containment. • Interior Finish: High solids, chemical -resistant epoxy coating with a white aliphatic polyurethane topcoat. • Exterior Finish: High solids, chemical -resistant epoxy undercoat with a heat reflective white aliphatic polyurethane topcoat. • Four (4) Hold-down Brackets (structural steel angles) for bolting to purchaser's foundation for seismic and wind load anchoring. • Static Grounding System: One (1) exterior grounding connection, one (1) 10-foot long 5/8" diameter copper -clad steel grounding rod, one (1) #4AWG copper conductor, and grounding lug(s). • Signage: D.O.T. hazard classification placard with rust -proof aluminum holder & stainless steel clips; and pressure sensitive NFPA 704 Hazard Rating Sign(s). DESIGN LOADS: • Roof Snow Load: 40 psf • Wind Load: 150 mph, Exposure C • Floor Live Load: 500 psf • Seismic Condition: Zone 4 or Performance Category E (3) DOOR PANIC BAR UL Listed Panic Exit Rim Device on the active door facilitating personnel exit from the - building. PARTITION WALL, 2-HOUR FIRE -RATED (With Sump Separator) Interior 2-Hour Fire -Rated Separation Wall, extending from the sump floor to the ceiling. Fabricated from UL Classified fire -resistive gypsum wallboard on each side of structural steel studs with thermafiber friction fit between studs. Both sides clad with galvannealed steel sheet. Interior wall divides the building into individual compartments and also divides the sump into separate secondary containment areas. LIGHTING, INTERIOR (135W Lama) (Explosion -Proof) Interior UL-Listed explosion -proof incandescent light fixture with a 135W lamp (120V, 1.25A, 1-Phase), rated for Class I, Division 1, Groups C & D, Hazardous Locations. Heavy-duty glass globe with a sealed heavy-duty aluminum housing and equipped with a protective metal guard. Equipped with an exterior UL Listed light switch (snap type) suitable for outdoor locations. EXHAUST VENTILATION, LOW EXTERIOR MOUNT (Explosion Proof) Consists of a UL Listed totally enclosed explosion -proof motor (60 Hz, 1-Phase) rated for Class I, Division 1, Group D, Hazardous Locations housed inside an exterior end wall enclosure. Non -static & non -sparking 12" diameter fan blade to preclude the ignition of hazardous vapors. Exterior exhaust fan housing constructed of heavy gauge steel, with an exterior polyurethane finish for maximum chemical & corrosion resistance.. Interior exhaust vent located within 12" of the floor for the extraction of heavier-than-air vapors. Exterior exhaust fan port opening protected with a UL Classified fire damper having a 3-hour fire protection rating. Fire damper has a galvanized steel frame, curtain -type galvanized steel blades, and a UL Listed 1650F fusible link. Exterior exhaust port equipped with shutter assembly. Equipped with an exterior UL Listed fan switch (snap type) suitable for outdoor locations. Automatic system shutdown if fire occurs. SHELVING (Adiustable, 16'D) Corrosion -resistant stainless steel adjustable shelving with clear zinc -coated supporting standards and brackets. Each shelf is 16" deep with a 1" lip on its front, back and side edges for secondary spill containment. Each shelf will support a uniformly distributed load of 80 psf. LOAD CENTER (Single Phase) UL Listed, 240/120V, single-phase load center (NEMA 3R) with circuit breaker(s) and main breaker. DRY CHEMICAL FIRE SUPPRESSION SYSTEM UL Listed & FM Approved pre-engineered system rated for Class A, B and C Fires. Fusible link detection for automatic actuation, Interior nozzle(s) for total flooding application. One (1) exterior UL Listed weatherproof audible alarm(! 20V. 0.1 A, 1-Fhase). Dry chemical agent storage cylinder {tank) and releasing device housed inside an exterior tamper -proof (key lockable) enclosure per the requirements of NF A 17 (Standard for Dry Chemical Pxtit7guishin Systems). System equipped with a means for remote annunciation. Automatic ventilation system shutdown (if applicable) upon system actuation. (4) FIBERGLASS GRATING Pultruded Fiberglass Floor Grating made from fire -retardant vinyl ester resin. `T-Bar" configuration with permanently bonded quartz grit/baked epoxy anti -slip grit surface for personnel safety. 35% open area for maximum spill containment collection. Superior strength, designed to sustain a uniformly distributed load of 500 psf. SUMP LINER, HIGH DENSITY POLYETHYLENE (HDPE) Seamless 30 mil thick acid/corrosive-resistant High Density Polyethylene (HDPE) sump liner providing protection for sump floor and walls. EMERGENCY LOCAL ALARM (Non -Explosion -Proof) Non -Explosion Proof Emergency Local Alarm Switch with Non -Explosion Proof Audible Alarm (general purpose use). STATE SEAL Florida Some states require state approval prior to shipping buildings into their jurisdictions. This includes in-house engineering time, approvals, inspections and insignias. (5)