#5th Change Order 03/20/2017TO:
Board of County Commissioners
From:
Roman Gastesi
County Administrator
Date:
March 20, 2017
RE:
Change Orders
Attached is a proposed Change Order #5 OAC Action Construction, Corp — Key Wes)
Airport Customs Facility Phase 11. The Contract Sum will be increased by $21,927.84.
The date of Substantial Completion as of the date of this Change Order is June 15,
2017.
According to Ordinance No. 004-1999 adopted ■ the Board of County Commissioners,
proposed change orders are to be presented to members of the Board of County
Commissioners at least 24 hours prior to approval, assuming they are within the
Administrator's prescribed limits. Change orders not within the Administrator's authority
are placed on the BOCC agenda.
Signature
County Administrator
Print Name
MONROE COUNTYIENGINEERING/ PROJECT
MANAGEMENT
CONTRACT CHANGE ORDER
PROJECT TITLE: CHANGE ORDER
Key West Airport Customs Facility Phase 11
3491 S. Roosevelt Blvd, Key West, FL 33040 INITIATION DATE: February 20, 2017
12540 SW 130 Street, Suite 3
Miami, FL 33186
U���-F-TAMJEM
W-70 771r UIT-Mm
This change order is for the costs associated with the design and installation of lightning
protection as a requirement of the building code.
This change Order is 1.67% of the criainal contract price.
kint valid until - .In npd by owner. Architect fif anniTcablel. a
1
K=2M4
- Argf-S Dale
AC MI codiftruction. Inc. I ate
M \
;Poswqo to
Roan Gastesi 02fte
Kevin Wilson
Christine Hurley
1 its OU;
a Change Order was not included in the original contract specifications. Yes E) No E]
I Yes, explanation: Lightning protection was not included in the original design. Lightning
protection is a requirement of the building code.
-7-MM
• - a - - I a a a a
MUMI=1 i •�
* Change Order is correcting an error or omission in design document. Yes [DNo n
11 111 1 ; III I 1111�I -
M=� III III III MIRIIIII IRIM I!I I III 1 1111 1 - I I - I I
IF
III
'-w
a
M..
kN FIT, FIMASIVII � . .
New Addifion-Design OravAngs - Drawling: AI/S $750.OT
Notes
1) Price is for Design Drawings only.
Bonded Ughtning Protection Symms, Inc. Standard Tomw: and Conditions of sale, dated 08M712M appry and are Incorporated by reference as part of thm
quotation and any work resulting from Oft quotation. Should you need a copy plea se cS 561-7464336 or vWt our websile of www bond edghtming cornitemis
V-...�
I WiTi I ZJ11 2 K01'.4 191-1
FAX: (561) 747-8233
WEB: www.bondedlightning.com
Scope of Proposal
1 1) Price is based on utilizing class I aluminum lightning protection materials
2) Proposal includes all labor, materials, shipping, and shop drawings unless noted below
3) The lightning protection system will be installed per UL96A, LPI 175, and NFPA 780 lightning protection standards
4) Upon completion of the project, a Lightning Protection Institute (LPI-IP) inspection and certification will be provide!
ACCEPTANCE • BID
The above specifications, terms and contract are satisfactory and we hereby authorize the performance of this work.
0=-
Patrick C. Dillon. President Print Name:
BONDED LIGHTNING PROTECTION SYSTEMS. INC. Company:
J M.
Sonded 1.19MIng Pmlecdm Systems, Inc Sta Tarrm and Con&-dons of sale, dated 081071X015 apply and are Incorporated by mference as part of this
quotation and any work msuNing from Oft quotation. Should you need 0 copy pkme caV 561-7464336 or visit our website at wwwbond efthtnIng.comamm
Corporate Office: Tampa Office:
2080 West Incharilown Rd. Ste 100 333 N. Falkenburg Road. Unit
3ONDED JUPITER, FLORIDA 33458 TAMPA. FLORIDA 33619 1
ec & TELEPHONE: (561) 746-4336 FAX: (561) 747-8233
Prot tiny People, Property Assets
EMAIL: maif@bondedlightning.com WEB: www.bondedligh Ming. cam
QUOTE #: 17-23130-29085
Date: 0211412017 Expires: 0411512017 Ref Specs: None
Project Key West International Airport Custons Termina
Location: 3491 South Roosevelt Blvd
Key West FIL 33040
United States of America
Estimate Total: $4,500.00
$4,600.00
Scope of Proposal
1) Proposal includes all labor, materials, shipping, and shop drawings unless noted below.
2) The above price is based on reusing the existing lightning protection equipment
3) The existing ground system, consisting of the downleads and ground rods, for the lightning protection system must remain intact
during there f process. Any needed repairs will be at an additional charge
4) The lightning protection system will be installed per L96A. LPI 175, and NFPA 780 lightning protection standards.
ACCEPTANCE OF BID
Patrick C. Dillon, President Print Namer
BONDED LIGHTNING PROTEC71ON SYSTEMS, INC. Company:
Date
Bonded Ughtning protection 5y ms, Inc. Standard Terms and conditions of sale, dated 0810772015 apply and are incorporated by reference as part of this
quotation and any work resulting from this quotation. Should you need a copy please call 581-748-4336 arv,slt our wabsite at bandedlightning CoMeMIS
VIKIWIl
UghbIng Rod Parts EqUilarnerd
_
Lim htni m , dParts.net
U '7�
fin I YA g Ro of S. ty—Uptning Protection Equipment and Purtig DLiZ,_
Toll Free (87?) 866-3189
>EIQMLW >L I cbW ng Proleab) n E itti 1pinenl(3} xUnr eWe&& -Tret-RodV31 >Fn n a y 1,16MIng- RVA I & Pa r 1 04) 'Afo Fancy R odst 51 >Abjet
>ffsolislyaks:112) & r!jQzr;IWjLUj—Far:3.W
(Z)a)Lommlfnimvjimfw
LIGHTNING RODS
Ridge Strap Lightning Rod and Mount
With 12"Sold Rod.
Copper or aluminum strop mount with cable cloarp
ter we on rid ip% flat or sloping mors—
Shipped flat but T=y be easily flonsud
as fit any ma slope.
Capkvrr.
cAmwac-4 12'RadI27,00
%% Ah 19' Rod NC-4-18 513,00
Alummom.
<x 11 w4h 12 Red SNAO
M,hh 19' Rod NA4-18 SELOO
LAngcr length rob add 51.00 per inch
in copper .10 in Aluminurn,
Swivel Lightning Rod with clansp base
Will 12" sold Red. Great for Installing behind Ridge V-1
Heavy coal copper or aluminum
For use an back side of mor to
hide meant from view
CLAWS am df COAFNEV
Economy Crillip Double Cable Splicer NI"Iti-purpose Parallel Bolted Clamp
Fingers we vim* ov dr- cable with pliers or hammered Hcovy Cast Cupp= or A lumioum bait pICISUPC CIAMq With BuUatCss aaa:1 bQ:L and woshcr
over the cable. Atecpts oil cables m Rail up to SM" - This is 0 gGcwl zU Vollso 1 c spliorr and can
(For a lamer boreal spleen see 0 MZ at Fight) substitute for most other cable clowaim
hNp:/A—WJV9hWror0dSUPPIY-Ccx! its
ZT=17
UqMng Rod Parts Equipment
steel bolts
Used when two cables cress as shown.
Copper.
OP-1 24'haH535,00
IA'and 24'PLVN SLOOMS
1 #P-2 18
01 nood 02 Said Mptoor
Copper: NC-27 1:141:14 is,
711
f3 and Plated Sled
NP4 24' tali $29AW
Pi
P2 P3
P4
Alummum:4,k-17 S16,50
#P-J Want 525,00
Al
Longer lengths add:
t
Cop, SLOO per inch.
Plaled steel .90 per Inch
Dow fats tooilable up 11, -45' oult
Copper an ndStninless steel
Sminicss steel is compatible with both Copper and
T Aluminum
Metal Roof Seam Cable Holder
For use on standings metal mofwh= no penetration of need is desired Como; complete
with #2 loop cable holder which can be amiched to either direction cfs=rs. - Aboidgatfor
looking cable to mooll't"Itcarn. Has 2 stainless steel baits end a W" opening on scsm.
SEE for Standing Seam
Lightning Rod and Bast.
Copper: #C-3 5;1.5€s ea..
Aluminum: 0 A-3 2 1111
GROUNDING(Zhoor Groan ly DetAUS an FAQs naa oJ
Ground Rods and Ground Rod Clamps
LEFT Ground Rod is 1/2" x 8 long settle orcupper ckol hardened suet. Long He corrosion
irsisteaL Note. Never connect aluminum underground,
Informed Rod (Left) 022 519,00 (Note Addhhmat shlpphtg 6j
hi . '1., U
gh shqptanr, o 6 c mo ad Mb TOY la,
u lA, L TMO V ra t Ins c6 it).
11 Capper^ �
a - d Chose (Rfthc) I
, 5 vo a . a —d. 5 11
0 C-Z far 34 tround rada 312,00
Used few corumaing copper cable to ground red.
311 Fit 1/2 " 57' - 3/4" ground rods 'Yont
FASTENERS
Cable Loop Fasteners
Sirup Capperer Aluminum loop type cable fastener
requiring one nail or screw-1/2" wide. Use one for every
3 fret ofcable.
Copper. # C- '30 -ch
'Firmed Copper, 9 2"w1 -5 J5 each
Aluminum- 0 A-2 A-4 cacb
Copper Ground Plate with Clamp
I square foot x 0.032 thick copper ft plate-
Comes coortiftac with inniched durnio for ground cable-
chipper.00-24 5 6LM1
I
where shallow top sail is
cricauntorcil -
For soil depths or i to 2 EL
Adhesive Cable Holder's
for Flat Roofs
Used for Camincircial typc mcmbrmc rinsfopplications
and whom roof lions
are not des' k. Tabs are bent or hammered over the
cable
Copper. 0 C
Aluminum. 4 A-V ' I si zr,
hVIAwirprIghtnInTockpapply.comfinclex filesipagftMhtnft, :is