Item C37BOARD OF COUNTY COMMISSIONERS AGENDA ITEM SUMMARY Meeting Date: April 16, 2014 Division: Public Works/Engineering Bulk Item: Yes X No _ Department: Facilities Maintenance Contact Person: Kevin Wilson/305-797-1547 AGENDA ITEM WORDING: Approval to purchase a 400 KW generator for $103,480.00 from Tradewinds Power Corp. (utilizing Florida Sheriff's Association Contract No. 13-11-0904) and associated cabling for $55,605 (from current County generator contractor All Power Generators Corp.) for the Murray E. Nelson Government and Cultural Center. ITEM BACKGROUND: A 400 KW generator will provide full building operation including climate control and replace the current lighting -only generator. A State of Florida Department of Health grant will reimburse the County 100% of the cost. PREVIOUS RELEVANT BOCC ACTION: None. CONTRACT/AGREEMENT CHANGES: n/a STAFF RECOMMENDATIONS: Approval TOTAL COST: $159,085 INDIRECT COST: BUDGETED: Yes X No DIFFERENTIAL OF LOCAL PREFERENCE: COST TO COUNTY:-O- (upon reimbursement) SOURCE OF FUNDS: 304 Infrastructure Sales Tax REVENUE PRODUCING: Yes No X AMOUNT PER MONTH Year APPROVED BY: County Atty _ OMB/Purchasing Risk Management DOCUMENTATION: Included X Not Required _ DISPOSITION: AGENDA ITEM # County of Monroe The Flonda Keys PUBLIC WORKS & ENGINEERING DIVISION MEMORANDUM DATE: 7 April 2014 TO: Commissioner FROM: Kevin Wilson s CC: Administrator BOARD OF COUNTY COMMISSIONERS Mayor Sylvia J. Murphy, District 5 Mayor Pro Tern, Danny L. Kolhage, District 1 George Neugent, District 2 Heather Carruthers, District 3 David Rice, District 4 SUBJECT: Full Building Generator for Nelson Government Center Action Requested: Approval of purchase and installation of a full building generator for the Nelson Government Center. Basis for Recommended Action: 1. The generator will be funded be Department of Health by reallocating FY14 unused state grant funds. 2. The existing generator supports only the emergency lights and communications systems. The replacement will support the full building including climate control. 3. With the replacement generator, the building could be used for all County functions during any extended power outage and could potentially be used for special needs sheltering to avoid transport to FIU for these citizens, when required. Background: The local Department of Health has sought funding for such a replacement generator for several years on the County's behalf. It was successful this year when unused grant funds were identified. The original design of the building included a full building generator which was removed from the scope to conserve capital prior to final design. The automatic transfer switch (ATS) was included in the design and construction in the hope that eventually the generator would be upgraded. Installation of a full building generator, which includes a fuel tank and connections to the existing ATS will permit full use of the building for normal operations; special needs sheltering (using the lobby or auditorium which is configured with moveable partitions and bathrooms), and, if necessary; or, as a base of operations for recovery work following any event. While the building is not designed for use as a backup emergency operations center, it houses both DOH and County staff who will be instrumental in any response operations. Addition of a full building generator at no cost to the County is the right thing to do. Staff recommends approval of the purchase contracts. One is from a State contract and the other is our generator service contractor. County of Monroe The Florida Keys � BOARD OF COUNTY COMMISSIONERS ;:. Mayor Sylvia J. Murphy, District 5 Mayor Pro Tern, Danny L. Kolhage, District 1 4 George Neugent, District 2 Heather Carruthers, District 3 David Rice, District 4 4 April 2014 Mr. Robert Eadie Florida Health — Monroe County 1100 Simonton Street Key West, FL 33040 SUBJECT: Purchase of Generator for MENGCC to Allow Special Needs Sheltering Dear Mr. Eadie: The County requests your approval to purchase a 400 kW generator and associated cabling using unallocated grant funds you identified. The purchase of this generator will provide sufficient power to allow full building operation including climate control during. This will make the building a candidate for use as a special needs shelter thus eliminating evacuation for these residents during most weather events. The total requested amount is $159,085. This consists of the purchase price of the generator itself ($103,480) plus the necessary cables ($55,605) to allow connection of the generator to the automatic transfer switch (installation of which is provided by the County). The generator installation (including permits, tie downs and pad, as needed) will be provided by the County. The attached two quotations are separate because the County can direct purchase the generator itself through a state-wide Sheriff's contract at a favorable price without sales tax. The cables will be provided by the County's generator maintenance contractor (All Power Generators Corporation). With your approval, the order will be placed and the generator purchased during this fiscal year. Thanks for your help. Regards, Kevin G. Wilson Director, Public Works & Engineering Division cc: Mr. R. Sanchez Mr. C. Dent Pierce Public Works & Engineering Division (305) 292-4560 1100 Simonton Street fax (305) 295-4321 Key West, FL 33040 RADEW1NDS 04AWT 5820 NW 84th Avenue • Miami, Florida 33166 Tel 305-592-9745 FAX 905-592-7461 www.tradewWdspower.com TO: Monroe County Fleet Management 3583 S. Roosevelt Blvd Quotation # PS24165Q Key West, FL 33040- March 18, 2014 Tel: (305)-292-3571 Fax: (305)-292-3529 Attn: Mr. Roy Sanchez We are pleased to offer this Quotation as detailed below Filters Pump Sets Power Units Generator Sets Automatic Engine Controls 1 iModel TP150 Mobile Generator Base Awarded Tradewinds Generator Set 54,900.54,900,1 Under FSA Contract No. 13-11-0904, Spec #49 "Low Bid" 1 (Cost Adder for Model T400-M-FS Approved Tradewinds Generator Set; 48,580.48,580' 1400 KW (500 KVA) Standby Power; 350 KW (438 KVA) Prime Power 1277/480 Volts [reconnectable], 60 Hz, Three Phase, 0.8 Power Factor IAmp Load Capacity: 602; Load Bank tested. �400 KW (500 KVA) Standby Power; 350 KW (438 KVA) Prime Power 120/208 Volts [reconnectable], 60 Hz, Three Phase, 0.8 Power Factor IAmp Load Capacity: 867, Load Bank tested. �400 KW (500 KVA) Standby Power; 350 KW (438 KVA) Prime Power 1120/240 Volts [reconnectable], 60 Hz, Three Phase, 0.8 Power Factor IAmp Load Capacity: 751; Load Bank tested. (Perkins Diesel engine, Model 2206D.E13TAG2 TIER 3 @ 1800 RPM complete with 12 Volt Electrics, Radiator & Guard !Oversized Brushless Single Bearing Alternator with a PMG and volts per hertz tracking jAutomatic Voltage Regulator, Special Insulation: Vacuum Pressure Impregnation and Rubber Vibration Isolation Mounts !Tradewinds NFPA 110 Digital Instrument/Control Panel with Safety Shutdowns lComplete DC Voltmeter, Hourmeter, Oil Gauges with and Temperature Frequency Meter, Ammeter & Voltmeter with Phase Selector Switch, Engine Cool Down Timer, Remote "E" Stop Contacts, Remote Auto Start Control, Low Fuel Level Alarm, Breakers for A/C and D/C, and a Emergency Stop Push Button. (Optional Equipment included in above pricing: Wet Battery, Battery Rack, and Battery Cables Thermostatically Controlled Jacket Water Heater with brass ball valves to enable heater element to be serviced without draining all of engine coolant. Overflow see through containment container mounted and installed. k 120vac, 20amp, Duplex electrical outlet mounted inside of weather enclosure and in a NEMA 3r box wired to the external of the weather enclosure to a standard 3 prong plug for connection to standard 120vac, 1 ph, 20amp service via extension cord. Steel Exhaust Flex, Critical Exhaust muffler and aluminized rain cap mounted and installed I in turn hood of enclosure. Turn hood will be treated with a sound attenuating material. .125 (1/8"), 5058 Marine Grade Aluminum, Sound attenuated weather Enclosure with vertical discharge air, stainless steel hardware, Keyed alike and removable doors, and Finished Painted a standard white PPG Powder Coat finish. The enclosure is wind load rated at 150mph and has an estimated noise level of 75dba at 21'. Enclosure will be equipped with four (4) area service lights that are prewired to a 0-60 D.c timer. 1200amp, Main line generator breaker to be provide for 208 and 240vac with 12vdc shunt trip. Breaker is prewired to single 1200amp compression lug connection box with safety shut-off E switch which will shut the unit down and open the breaker if door is open while running. 18,0001b, Steel, D.O.T. Approved, street legal trailer with Dual Torque Spring Axels, Surge Brakes, Fenders, two (2) rear mounted jack stands, tongue mounted trailer leveler, running lights with reverse lights, military hitch, safety chains, and a 500 gallon steel fuel tank. The fuel tank will be equipped with a mechanical and electrical fuel level gauge and have a low fuel level alarm, tank drain, tank fill, suction and return lines. Trailer and subbase shall be finished painted a two part epoxy paint that will help protect components from earlier failure due to corrosion. Standard 7 pin connector and reverse electric dump valve. I Distribution panel to include two (2) Duplex Receptacle with GFI Trips i and breakers, Two (2) non-GFI Duplex Receptacle with Breakers, One (1) 120vac, 1ph, 30amp, receptacle, 120/240vac, 1ph, 30amp receptacle, and One (1) 50amp, 120/240vac, 1 ph receptacle. Each receptacle is protected by a single breaker located in the load center. Two Thumb screws are provided for remote start stop contacts of Transfer Switch in NEMA 3r cover box. j Oil and Water Drain Lines with Brass Ball Valves and Bulk Head Fittings. Initial Fill of Oil and Antifreeze Full load factory test of generator set and operation test of each system. ` One complete operation and maintenance manuals to be sent after completion under separate cover with as -built. I One lockable Aluminum storage box. Two (2) Year, Tradewinds Standby Warranty Sub Total, FOB our warehouse, Miami, Florida 103,480 IOnsite Start-up and building load test Inc.; Inc.. Delivery to Key West, FI. Curbside. Fuel by others Inc.: Inc.: Total 103,480 (State & Local Tax as Applicable Estimated Shiooina date from receiot of order: 12 - 14 weeks. Wire -Transfer: Tradewinds Power Corp Division of South F/B/O Wells Fargo Bank Acct# 4945741023 ABA# 121000248 , GENES T P 5 comma. -WE SE_%/ICE OF r�ENE.7B/1.T0.'�25' Name / Address COUNTY OF MONROE FLEET MANAGEMENT ACCOUNTS PAYABLE 3583 SOUTH ROOSEVELT BLVD KEY WEST, FL 33040 9841 N.W. 1 17th WAY MEDLEY, FL 33178 Ship To Quote Date Estimate # 3/24/2014 4582 Terms Rep Serial Model Net 30 LUIS Description Qty Total THE FOLLOWING IS OUR PROPOSAL TOTAL OF 6 CABLES PER PHASE, 4 PHASES. RUN 200 FEET OF CABLES FROM GENERATOR TO TRANSFER SWITCH THROUGH EXISTING CONDUIT CONNECT ELECTRICALLY TO EXISTING ATS CONNECT ELECTRICALLY TO EXISTING GENERATOR ALL POWER WILL PROVIDE FLAT BED TRUCK FOR TRANSPORTATION ALL POWER WILL PROVIDE MACHINE TO PULL CABLES ALL POWER WILL PROVIDE 3 MEN TO CONDUCT WORK TEST UNIT WHEN COMPLETED 350 MCM CABLES 200 FEET EACH 24 38,280.00T RENTAL EQUIPMENT, CABLE PULLER 7 2,975.00T TRANSPORTATION, FLAT BED TRUCK 2 2,500.00T LABOR 3 MEN 150 11,250.00T MISC MATERIALS I 600.00T NOTE: ANY OTHER WORK NOT INCLUDED IN THIS PROPOSAL SHALL BE QUOTED ADDITIONALLY. Subtotal $55.605.00 50% deposit required upon approval. Sales Tax (0.0u ) In the event of any action brought to enforce the payment terms of this Contract or Invoice, $0.00 the prevailing party will be entited to reasonable attorney fees to be paid by the non -prevailing party. Total You agree that simple interest of 12% per annum will be added to amounts invoiced and not $55,605.00 paid in tuii within 30 days aver your reccipi of our invoice. Hn rrrvoicc win uc uccmcu Phone # Fax # E-mail Web Site 305-888-0059 305-888-2090 lmaldonado@allpowergenerators.com www.allpowergenerators.com