Loading...
09/18/2019 Agreement A:= C A KA E R f C A N E IJ G p hi E E R S F, ( C)N,T R'A C-1 0 R'> N ..........Items lined through are t ...o be August 25, 2019 provided by others Ms. Suzi Rubio Executive Administrator to Kevin G. Wilson, P.E., Assistant County Administrator ................................................. 102050 Overseas Hwy., Suite 219 Key Largo, FL 33037 Cell: 305-393-6277 Office: 305-453-8788 Rubio-Suzanne@MonroeCounty-FL.gov RE: PROPOSAL FOR TESTING, ENGINEERING DESIGN AND APPROVAL OF WASTEWATER PLACE IN OPERATION (PIO) FOR THE GOVERNMENT CENTER 88820 Overseas Highway, Plantation Key, FL 33070 Dear Ms. Rubio: American Engineers & Contractors, Inc. (AEC) is pleased to present this proposal for necessary testing, construction and approval for Notice to Place in Operation (PIO) required by Village of Islamorada, Key Largo Wastewater Treatment District (KLWTD) and FDEP. Please note that the design and construction scope is based on recent site evaluation, AEC's past experience for testing and repair of the existing system, review of drawings prepared by Kimley Horn Associates dated 06/21/201 and current requirements of Village of Islamorada, KLWTD and FDEP. The proposed scope will also satisfy the intent of FDEP permit 281237-280-DWC/CL for construction and any deviation will be noted in the PIO application to FDEP, as reviewed by Village and KLWTD. AEC will assume the revised engineering design and construction certification responsibility as the Engineer-of-Record for the project. The following tasks are proposed: • Conduct meeting with the Village Engineer to address sanitary sewer requirements for necessary tasks to obtain PIO for connection to Village of Islamorada sanitary sewer connection. ® Coordinate with all project stake holders, Monroe County, Village of Islamorada Utility, Village of Islamorada Building Dept., Key Largo Children Shelter, Biltmore Construction, Key Largo Wastewater Treatment District (KLWTD) and FDEP for successful completion of the project. Page 1. 224 Fbtura St,Ste 709,W. FlArn Beach,F11 33401 I 80925 overseas Ffighway,#7,Wwnorada, FL 33036 P 561889 6621. I kffo@AECbufld.covn I AECbuftcorn AEC AKAE;ftICAN lI'G Nk hN F� ( 0N'fRA( IC)Ftk fN(_ • Design and develop engineering drawings and sanitary system design for Village of Islamoraa Building permit application (infrastructure to include new grease interceptor for Children Shelter), ® Submit the Building permit application package to Wade Trim for review and approval. • Coordinate and address any design review comment from Wade Trim and re-submit to the Village for review. • Coordinate and follow-up on submittal to KL TIC, address design review comments and re-submit to Wade Trim for KLWTD sign off, • Address P@s permitting staff review comments and re-submit PIC application, as required, ® Develop comprehensive testing protocol based on 'Minimum Design & Construction Standards and specifications for Wastewater'developed by Wade Trim, dated May 2019. • Hydrostatic pressure testing protocol will include the following components of the existing wastewater collection/transmission systems: 1. All laterals to main gravity line, including wyes 2, Main sewer limes 3, Manholes and Cleanouts 4. Crease Interceptor Specifically, the following components will be tested and certified, 1, Lateral to modular Main to Manhole 2. Lateral to detention center 3. Lateral to children shelter 4. Lateral to court house 5, Manhole 6, Manhole 7, New lateral from manhole 1 to new lift station 6. New lift station wet well, new force main to street connection 9. Crease interceptor serving the Children Shelter ® Provide signed and sealed engineering drawings for grease interceptor for the Children Shelter to incorporate in the existing collection/transmission system serving the proposed project. Page 2. 2.24 Datum Son„Ste 709,W.Pallrmu Beach,FL 33401 I 80925 overseas Qi h ay„ 7R Wa moor da,IF L 33036 P 561.889 662111 4 fo AECbufld.coirmn I AEODufld.com AEC • Install County supplied G250 high efficiency grease interceptor as per based on 'Minimum Design & Construction Standards and specifications forWastewater' and construct structural slab for traffic bearing and recent plumbing code, • New mini lift station and temporary force main to Manhole 5 to divert sewer from Ellis Building around construction • Coordinate with Village representative, Key Largo Wastewater Treatment District (KL T ) personnel and Building plumbing inspectors on requirements for pressure testing and leakage testing to be done in accordance with the current AC-600 standards, • Prepare and submit signed and sealed detailed Condition Report to Village for tie-in approval. The Condition report will meet the intended Village design and construction standards and specifications. • Prepare signed and sealed drawing of the collection/transmission system tested including all the pipe details (length and diameter). • The report will also include written evaluation of the condition of the existing collection transmission system including all gravity mains, laterals, manholes® pump stations, treatment facilities, forcemain, valves, contrail panels etc. • Provide results of testing conducted indicating the test passed or failed, describing the repairs to correct deficiencies and results of retesting, • Prepare Salinity test results,testing procedure,method of calibration with field instruments and submit signed and sealed Salinity Certification Letter as per Village requirements, • Certify field testing for salinity and submit documentation in accordance with the Florida Department of Environmental Protection (F EP) FT 130- Field Measurement of Salinity, dated March 31, 2006 • Prepare and complete F EPes Request for Approval to Place Domestic Wastewater Collection/Transmission System in Operation [FDEP Form 2- 0 .3 ( )( )] package and submit to Village of Islamora a for approval. The package will also include certified Condition Report,Test Log, Salinity Certification Letter and Salinity Report, as required by the Village, • Address any review comments from Village and KLWTD on the submitted package and re-submit for approval, as required, • Submit final signed package from the Village and KLWTD to FDEP for obtaining 'CLEARANCE'. Page 3 17.4 IDa ura St,Ste 709,W.Mirrn Beach,Fll...33401 Q 80925 Overseas(Highway, 7„W m creche FL 33036 IF 561889 6621 1irifo@AECbufld,.com d AECbufld.coim I- M F,PC[C A r) 'c NAEE " N�I`R A C 1()R"w f N 0 Address review comments from FI EP for issuing `CLEARED TO USE' of the collection and transmission system. We shall provide the work scope as described in this proposal as per following breakdown. 1. Engineering design drawings to incorporate the new grease interceptor for Children Shelter including permitting &testing observations with Village of Islamora a - $7,500 2: I ,tai. fi n.... f..-Grea" -Interceptor, -water-tight- ,.cogs - ,cow— ste slab -for traffic. . T st+fig..f r t f tl w° g corn,po b- Leta * t - ti -center c Let to r n-a er d-. Ie tar l-trr- rt-house. e: Manhole-4 f; -5 g I ,w...9 # rl.,fr ..,rn� f..tur eft stair h. ttft Lion .well,n w ter -t street„ry tion i r y 4. Witness testing and camera investigation, coordinate inspections with Village of Islamora a and KL T . Prepare as-builts, test log, salinity certifications and F EP approval to place system in operation. Assume design responsibility as new Engineer-of- Record -$15,000 Alt mate fir Itis.. i ... ad .. r � lift t rend pr. s.. 0g ft ref rsr in to please rate that the new plans call for demolition of approx. 365 It of --inch gravity main and two (2) manholes, so no testing is proposed. However, for PIO Village and KLKITD will required testing for these components] For above cost proposal, please note that associated permit application fees, survey(if required) are not part of this proposal, and to be reimbursed on cost-basis. Requested Terms of Payment will based on a 20% retainer and progress percentage completion. Please be advised that the proposed work is based on anticipated scope and current regulatory requirement, Though not anticipated® please note that any additionally imposed regulatory requirements based on review of the permit application may affect the scope and pricing of this proposal and will be brought to your attention promptly. Page 4 7.7.4 Da uira St,.Ste 709,W.Palm Beach,R.,33401 i 3 925 Overseas Rig away,##7,Warnurr da, FL 33036 P 561889�621. i 'binfo@AECbuun�d.corru i AIE bufld.corru Z111 Mease mote that any addftionW services WH be 1provided at an houdy ante of 00 per hour. Mease fed tree to cMI at 561 889 6621, in case of any quesdons or dadfications, Respectfully submitted, MONFIOE COUNTY ATTORNEY N ,f f Il r lyn„n u ANNIN `N` N t9V6 6' /f yn Pdndpal �m CHMS A N t 1 A WAN T COUNTY ATTORNEY NEY FL ProfessNonal Engineer#56899 F"L Certifiedern r N Contractor��t 1 1 "l ate m� ._ :. .............. American Board Certified I rnvirorurrn rnt N I ng4-n r(;N t°°;:E") Acceptance- ��o" ^pks(noD uw Su.u°aQna LIMITA TION fyFl..lAlBILITY 7b the fullest extent permitted by law„ the total liability, in aggregate, of our Agents, I.."rofesslonal Associatos an Consultants,and any of them to Client and anyone cl lrrndrng tly,through or under Client,for any and all lrnjurlesw claims, losses,expenses,or damages hats ver arising out of or in any array related to this project from any cages,including but not limited to negligence, errors, orrrlsslanrns„ strict liability or breach of contract, shall riot exceed the total compensation received by ors seater this agreement. pmdC,k /,,P 224 Datuwr:a Pr„Ste 709,VV,F41m Beach F1 33401 I 80925 n ,1/rirsr^!rn G-Ifi hl %ta!a+l,47, Vw,Naf nrri rangy a„ FL 33036 561 889 6623 ld:a (°bwld� : m