Loading...
Item L1 L.1 G BOARD OF COUNTY COMMISSIONERS County of Monroe Mayor Sylvia Murphy,District 5 The Florida Keys l'U � � Mayor Pro Tern Danny Kolhage,District 1 �pw° Michelle Coldiron,District 2 Heather Carruthers,District 3 David Rice,District 4 County Commission Meeting November 20, 2019 Agenda Item Number: L.1 Agenda Item Summary #6233 BULK ITEM: No DEPARTMENT: Project Management TIME APPROXIMATE: STAFF CONTACT: Cary Knight(305) 292-4527 10:00 A.M. AGENDA ITEM WORDING: Presentation of the results of site selection review for the Emergency Operations Center (EOC) at the Marathon airport and BOCC concurrence with the proposed site. ITEM BACKGROUND: The project team [County staff and Architect's Design Group (ADG)] have evaluated possible sites on the Marathon airport property for construction of the Emergency Operations Center (EOC). The team will review the options considered; how the sites considered affect or are affected by the Marathon airport master plan; and the basis for the recommended site at the southwest corner of the airport property. PREVIOUS RELEVANT BOCC ACTION: 2/18/09 - BOCC approved a contract with ADG for the design through construction administration of a new EOC in Marathon. 10/1/09 - BOCC approved a First Amendment to the contract with ADG to include information technology needs to the design. 11/14/17 - BOCC ratified a Second Amendment to the contract with ADG to develop an updated construction estimate with modifications to the design for a new site and slightly revised scope. 09/19/18- BOCC approved a state-funded grant agreement in the amount of $5,900.00 with the Florida Division of Emergency Management for the purpose of planning, designing and constructing a Monroe County Emergency Operations and Public Safety Center. 12/19/18- BOCC approved a Public Transportation Grant Agreement with the Florida Department of Transportation in the amount of $400,000 for the purpose of planning, designing and constructing a FL Keys Marathon Airport Non-Aeronautical Use Building, to be considered for use as the EOC. 3/21/19 - BOCC approved staff request to negotiate with ADG a professional services contract to provide design and construction administration services for the Monroe County EOC. 5/22/19 — BOCC Approved award of a contract to ADG to provide design and construction administration services for the Monroe County EOC. Packet Pg. 2119 L.1 8/21/19— BOCC approved a revised contract with ADG which changed the name of the EOC building to "FL Keys Marathon Airport Non-Aeronautical Use Building" due to requirements of Monroe County's acceptance of an FDOT grant agreement. CONTRACT/AGREEMENT CHANGES: N/A STAFF RECOMMENDATION: BOCC approval of proposed site selection DOCUMENTATION: FINANCIAL IMPACT: Effective Date: n/a Expiration Date: n/a Total Dollar Value of Contract: Total Cost to County: TBD Current Year Portion: Budgeted: Yes Source of Funds: Legislative Grant (FDEM - 100% state funds), FDOT (50% matching County funds). FEMA HMGP (-25% matching County funds; application approved by FEMA, grant agreement pending approval by BOCC) (FDEM State Funds will be used for County Match to HMGP & FDOT grants) CPI: Indirect Costs: Estimated Ongoing Costs Not Included in above dollar amounts: Revenue Producing: No If yes, amount: Grant: Yes County Match: Yes Insurance Required: (For work being performed by ADG, as specified in the ADG contract, yes.) Additional Details: N/A REVIEWED BY: Cary Knight Completed 11/05/2019 8:20 AM Kevin Wilson Completed 11/05/2019 9:32 AM Breanne Erickson Completed 11/05/2019 9:58 AM Cynthia Hall Completed 11/05/2019 10:00 AM Budget and Finance Skipped 10/29/2019 4:58 PM Maria Slavik Skipped 10/29/2019 4:58 PM Kathy Peters Completed 11/05/2019 10:12 AM Packet Pg. 2120 L.1 Board of County Commissioners Pending 11/20/2019 9:00 AM Packet Pg. 2121 Monroe County Emergency Operations Center Florida Keys Marathon Airport Non-Aeronautical Building '' '' 8, ,, ,,4...,7 • lilt 4, " WM IP .411°4 r A ...........4da : - ('" +' 2 I t. _ r� Architects Design Group Winter Park, FL I Dallas, Tx In association with K2M Design Li I ntrod uction to M on roe Co u nty E O C • A New, Hardened Structure Built to FEMA P-361 Standards • Located at Florida Keys Marathon Airport • Occupants : - Emergency Operations Center - MC Emergency Management - MC Fire Administration Site Criteria • Main Factors For Determining an EOC ( FEMA IS-775) - Accessibility (Ingress / Egress) - Location (Airport Property / Master Plan / Grants / FAA Part 77 Protected Airspace) - Safety (Stand Off Distance 82' — Homeland Security) - Size - Systems Capability (FAA Part 77 Protected Airspace, Communications) - Survivability - Versatility (Redundant Utilities) Site Assessment A , • a ; st . " riVii •r . 3 4. 4 • art, , ; "►„ , . -,ar • . �, N.: ,,� 1. +r . 3 a a:► tYt4 1fe ' 4+itr� '•Jl r •�. � , :'f', r ! .t+r qy .•�`� itn .•4+ 4 4 �•Remote Communication i .S Y 4 ASOS� s ,. t! �' • ti�5 ♦rC r Air/Ground(RCAG)Facility • �. rt • IIIAL AI:t r Nov ...�, �..: ik..-...-Algitita Agt '41hries1-. AA' •!.i ......1.1.-...—_-.......k.—z-N--.•wspr " ,...,,•,.,. • ♦..:.r:nn Blvd. .4Z.- 7 General Aviation Apron Expansion 6 -4...... 5 s -o' (18,200 square ards) .. 40'Runway Shift North -' - C f - rP -41.1b. ; .�, i._. v- rw r' 4,,,,, as Commercial Apron' . it.ri.' ''' .... ^ t -- ' • r i { ; 3ii$JUo •. .• [ rtat. d,',i 3 Aviation Apron ..." +1 z c 64 trd.'l:.ads P:, ..a t ci,.:-. .. . .� • — . , s- -....0 a:- • , - ; Emergency • Retentions Aircraft Relocatedve /�' ( Maintenance �i! Air Traffic Roadway GeneralI, j Aircraft ,•' • Indoor Operations >Pond Drainage Hangars/ Fuel Storage.it 414 "4' V p, Storage p. Control Tower Connector Aviation ♦a� Y,,r Hangars ; Shooting ~ 'Center(EOC)a Area €, Apron Facility ,r.,'�' ! Facility `. . / -.. Apron 4 4 / Range 4 �t a: .�. ' �` jK • • V � ��s • 1� , t `);� �',.Expansion rI•' F:s. Lit. • Fe.,,.-v:!, f`ika;;3 : r . .• ;'Of f t- >`•� � ,� ," ,'' .7 . : •v.4 1 ,, ri. ot?, ♦ . 6y';�ya�Jy{��• .•• • 4 A• , • 7'; 'P ,t: ,r t' am +► :. a tJ/. 11 • u«»�• ! ,.�'. `y ;., ;'!"•!,3'�` ,;' ,4 ``r - •` sue. ow v,t • Li ...mumn...,•s•.••.w.... M .� I , -a.».,0...+,... Atlantic Ocean Site Assessment t'%, t aim of • 40. dIte: So 3) .., - ..c.,,lor, *Asst sofera •••. '''' _#.. .„,, ... vvir .e.\.:-, •re"•I6.4 •si• i P IP,.., 1,, _. ,..4,i'. .,401 . i • 1 a -4.11 eq,• a' , •"r, 4.i.. r ,-„-, , ., . ,..• , . 4, , ., , •1' 4 4 , 4 ..41 . ' k ,...‘• . ,. . .14... , ''. i „ , .-b::,.: ...._ •4., v.. ...s. . , , -4, -• ,414 ' ' ' 1 ir— FAA Remote Air/ Ground Facility V4— Violates FAA Part 77 , , . _ 4 .:'.......1; I IP ' r• (RCAG) Antenna location - In « '4,s'i - Requirements - not allowed . . 1.. ries.craine ‘4,0;* 14., 4:1 Progress —Already used . . !.."..\- l' 1.41W41;451zr- *4 woli, •&lel ik, -t 4,t... ..; -.._ . , 4 • - 4. r`"NIMINOMPPIWA Air/Ground(RCA1)Facility NIIr• ilk Illt 4 ASOS ' TV-s • silk 1.( ,..,,,....•• .%i.4.- it • ' "' • -1 Blvd. General Aviation Apron Expansion . 'atl....L.; 08,200 square yards) ... 40'Runway Shift North - .. 7 .0%, •-• - ,, • , ' timate Runway 7-25 (5400'x 75') . . _____,.__ .. "i•. , ,t.,-;r • IFicA) ilr' -,,It • ' — (.- - .:..:i..:?..,:.:•:.,::::i.:;:?;.,§..::::..:•..;:•:::•••• •••••':'•::•:::-:•::-.•:••:•:'••.•-:• ' ,.;.!...::::•::,.:;:.::::::::F-,5,:i,„.:„,,,p,,,,,:-i.,.,,,..7_7:7.,..,,,,„,...„„*.m.„,5,51,r:„....,..Av:::.'.,:.:,....:vii, ,-110r-, , '•''', .- r_ •:„.. , ... ,iiiiiiiii.i.....„:„,...:.;.:;:;.......0;:_"...., ..4. :,.. ......, . .- .........i.i_ ..._ ._ . . ''. ..4,.....,4 ,,.,.....,„...,.:. ,,...,71.,..,e4,.. ..ip, . .. ..As. ... 11, .4.-'••s al _E r-t--,..%if 11144114 MI.aft•1 I, . . Com...,mercial Apron ., - --.4.-64.'• ,,filMIZ els . General a General Aviation Apron r. -,s • .7.11...7, '• . Aviation Apron r ....•`,..,A.A.,„,...1. 4. ,iii fa E.- gency Retention Aircraft •: Relocatec, t„ _ , it_.- , '.., Maintenance t Air Traffic Roadway.,General ;, ' I Aircraft li loor i Op tions Pond Drainage ,Hangars/iFuel Storage: :,',•, tr N., 7,,,,„ il Storage 1`;;Control Towei Connector•"' Aviation . 4.." Ns ,'Cent E0C11 Area i Apron 1, Facility .114,11:-flollyill• - i‘s, It Facility_ l-,4 , il4ii . ,‘ .Nii.-.*: Hangars , _. Si.Joting '14 1., .tinge 4 ....,.4. .1«,sp,... ' N":1;7,..Y:,e4,f ExApparnostilon , .4... ai. ..k i i11 it., - /I% ' Airport Drainage System 17 . -: . .licior - v.', ' ''' ' ..., N.• Easy access to US 1 and Aviation Blvd. , ! Part of an already in Building Height Violates FAA Part 77 Final Hanger Development I ,e • Furthest away from airport functions tik progress five year plan as :. Not Enough Space for Building by Master Plan • Allows for 82' security setback easily - identified in the Master , Terminal Parking Conflicts with Not Enough Space N • Will not penetrate FAA Part 77 plan. FAA Part 77 Security Requirements I protected space Constraints 11 '---•:". • Conceptual Layout V , • _ _ _ ..... .„ ;; ,16.,.: ...... ----- - ".• ' i,l,ii, -or 7 _.. , ,.. K: • .", f'. v ;'1,..-.. ,,,,: : I e, .-. tv.. 44,,,,. 1 r t ."tl,..) .•., .., I PSECUING RED ARK.,..., '','. ' "t- ' ,---•er-I . '. ;.,......gsf...,,.., (..%1'.._'.`.s.' ' .-- ..e...,: ..;.. ,td•.,,,,„; MONROE COUNTY , fr. . '.-- •••.—tY I ...ip.-j.v, „,..t-; :*.,..4.".''-;:,, c, LANDSCAPE EMERGENCY PROTECTION OPERATIONS ) ,i.,•'' ....1"ltfr„:' .Tit 41....t*,....4'.d•: 1‘';.1....n,'4., Ea' swALE .." ,.... CENTER . RETENTON I -.:-4 4.1:;4';'.:1 .7 .".. ,...''l'''''XI- •tr"A''':''-N Z ..,- ?*;..'• : 0 •.1, .....k.6., " .;:i:',.iii'';:, .- '',... '1,::'02.'; * i= :.*. i:‘'.i'? ' •:::•''fAAff,': 42'47, `A''eti 1p tor '.•".•• .'.3-'''.'&?:- ..,..",..7'..?"t.o.,...--',4,. .-. ii."&.,P.,:t; ' <:....f.:7::‘,1!, i,•:!, ...,"' • , ..,.... .. < • I . ' I I .44. ,..k-' .• ,, '..‹.'"--'>\ . , , r:. • jks(04V I . . • ..°' * : f.-.) PLAZA . ...- ' • 4N.NIIir 4. • .. ..• _ L._ j( ... . .t • ',.::-.,..... *ill .e -'0 •S . 1 /1.141 110' Security buffer I /'Th / ,:,......-.3,‘,.•:\ri, •!\s, ----.: --- ''''''''•-'t.. .\ `.:;1.'".i.u,'"'"z'''.1-77.1 46;-'1,`, ..). .:2- - I ------ t ' ' k. '• ., ..5,0101. $11‘i \ - ' % k,z c,..'" 4:,,,"' . . •-••‘. I ..- Ade ‘‘•:\. V..., ...- . , ... •,,•- 40.sit'' • , `I:* L- I.--- .- ) .03 ,.,•-•,..V . -. \ .........- •. EX TING PARKING............'" -,.. ,...,,, •.., . ) ,..1' 9.50.. b‘J ". Iff — 9.* ' q ''• .'••••."' -='' , t . • ..... 0ro,- ••• k. 4.. .. . . .*, ';•..• •.,14 .4-11,:I` ., PUMPS . er -- :"...,..i „ ,.. ,,, ., • ......, .1, • ''.c:i.l..,:i!'',../,..0*.: , STATION k......--;•,...0 .4--).-.• , . . s. -1-49,1frrP ,, s$ , , 1 ' 1, • ''- ... ...L.:, ..,t y'',, -.. 94. .''1•'. . ..- \.,er'-- . !. ' ,' ' ••• ii ; •,..--0 _.--- s- ...... ,,.." , ... -- 4 si ' lit. 0 . •.. ''' f...AP, .,-,....,-..I II 4.?.,.. 4)S• :.?•,, \ ,--- '' c,,!-- 1 _ ,) SfTE DIAGRAM 6 \ / Next Ste ps • With approval of recommended site •We •Continue with space programming •Start with Phase II Design