D.L. PORTER CONSTRUCTORS, INC.
6574 Palmer Park Circle
Sarasota, FL 34238
(941) 929-9400 - Fax (941) 929-9500
REOUEST FOR INFORMATION
Date 11/7/19 RFI # 14
JOB # 1705
TO: McFarland Johnson Project: Marathon Airport Car Wash
2409 N. Roosevelt Blvd., Suite 4 Marathon, Fl
Key West, FL 33040
Attn: 1V11Ke EcKnarat Yrom: leremv Mosher
Reference: Drawings: A-1.01 Spec Section: NA
Reason for Request: [ ] Insufficient Information [X ] Conflict in Documents
[ ] Interpretation of Documents [ ] Other
Probable Affect "Cost:" [ ] Increase [ ] Decrease [ ] No Change [ X ]Unclear at this time
Probable Affect "Schedule:" [ ] Increase [ ] Decrease [ ] No Change [ X ] Unclear at this time
Response Required by: ASAP Subs Sub Requesting Info:
Information needed:
If you refer to 2/A1.01, the concrete base of the bollards is shown to be 2' x 2'. This will
interfere with the grade beam. The grade beam extends 10" from the face of the wall. The steel
bollard is shown 9" from the face of the wall. Please advise.
A.E. Reply:
cc: File / Jobsite — Jeff Weisshaar, Jeremy M.
Joe Petzack
From: Martha Carvallo <mcarvallo@cartayaandassociates.com>
Sent: Monday, November 11, 2019 10:05 AM
To: Joe Petzack; John Mafera
Cc: DelVerme, Luca; Mike A. Eckhardt; Robert J. Buerkle; Juan Justiniano
Subject: RE: Marathon Carwash RFI No. 14
Joe,
The bollards on the interior are not a code requirement. They are there for protecting the wall.
Thanks,
Martha Carvallo RA, NCARB
Al(,adaya,and Associates Architects, PA,
www c atiayN:xart(.IassociEites,coir�
From: Joe Petzack [mailto:jpetzack@mjinc.com]
Sent: Monday, November 11, 2019 9:01 AM
To: John Mafera <jmafera@mjinc.com>; Martha Carvallo<mcarvallo@cartayaandassociates.com>
Cc: DelVerme, Luca <Idelverme@avconinc.com>; Mike A. Eckhardt <MEckhardt@mjinc.com>; Robert J. Buerkle
<RBuerkle@mjinc.com>; Juan Justiniano<jjustiniano@cartayaandassociates.com>
Subject: RE: Marathon Carwash RFI No. 14
Martha,
Please confirm, as time is of the essence.
Thank you.
From: John Mafera <imaferaC miic.com>
Sent: Monday, November 11, 2019 8:57 AM
To: Joe Petzack <Ipetzack _ miinc.com>; Martha Carvallo<mcarvalloC@cartayaandassociates.com>
Cc: DelVerme, Luca <lelverme avconinc.com>; Mike A. Eckhardt < Eckhardt __ miinc.com>; Robert J. Buerkle
<RBuerkle iinc.com>; Juan Justiniano <iiustiniano cartayaandassociates.co>
Subject: RE: Marathon Carwash RFI No. 14
Joe,
I spoke with the client yesterday about this and he is fine removing the interior bollards assuming they are not required
by building code.
Thanks,
John
Johii L. Mafeno
Regional Director ofAviation
0: 305-705-4871 ° C�321-431'7029
From: Joe Petzack
Sent: Friday, Noxemnber8, 2019 3:55 PM
To: Martha [arva||o<
Cc: De|Verme, Luca <>; Mike A. Eckhardt <>; Rmbert]. Buerk|e
<>;]uan]usdniano >; John &4afera < >
Subject: Re: Marathon CanwashRF| No. 14
I'm currently away from my laptop, so I'm not certain what part of our email thread I'm responding to. With respect to
your comments earlier removing bollards by first checking with the client - would removal of the interior bollards pose a
code issue? Or is this merely a safety aspect? Please advise, as this will provide the client with what they require to
proceed.
Thank you.
Sent from my iPhone
Joe,
We would like to keep the exterior bollard detail as is. The bollards could be moved a few inches away
from the building to allow for the pouring of the foundation against the grade beam.
Thanks,
<imnageOO1'pg> Martha Conva0oRA, NCAR8
Garlaymand Associates Architects f�A-
2400E�'Connnercia/BnulevmntSuile.2D/
FodLeuderdale.FL, 33308
p(Q54)771-2724Fxt 121
Fronm:DeK/ernne Luca
Sent: Friday, November 8, 2019 11:36 AM
To: Joe Petoack K8arthaCanmUo
Cc: Mike A.Eckhardt Robert ].Buerkke
Subject: RE: Marathon Carwash RFI No. 14
The bollard detail asit stands is great for the exterior application. Did the GC price up deep foundation
bollard detail in the building?
Luca DelVerme, PE
D.L. PORTER CONSTRUCTORS, INC.
6574 Palmer Park Circle
Sarasota, FL 34238
(941) 929-9400 - Fax (941) 929-9500
REQUEST FOR INFORMATION
Date 4/22/19 RFI # 01
JOB # 1705
TO: McFarland Johnson Project: Marathon Airport Car Wash
2409 N. Roosevelt Blvd., Suite 4 Marathon, FI
Key West, FL 33040
1' l VIER. Jus unn 1V1V.lLG®-
Reference: Drawings: Various Spec Section: NA
Reason for Request: I Insufficient Information Conflict in Documents
X I Interpretation of Documents Other
Probable Affect "Cost:" Increase I Decrease 1X1 No Change f I Unclear at this time
Probable Affect "Schedule:" Increase I Decrease I X1 No Change Unclear at this time
Response Required by: ASAP Subs Sub Requesting Info:
Information needed:
Drawing S4.03 shows a concrete ribbon beam around the perimeter of the hollowcore with (2) - #5
continuous. When you look at the detail on sheet A-3.01, it appears that this is a 4" split face block.
Sheet A-2.01 which has the building elevations also does not show a band around the building at this
location. Please advise.
A.E. Reply:
cc: File / Jobsite— Peter Jorgensen, Jeremy M.
Joe Petzack
From:
DelVerme, Luca <Idelverme@avconinc.com>
Sent:
Tuesday, April 23, 2019 1:28 PM
To:
Mike A. Eckhardt; Juan Justiniano
Cc:
Joe Petzack; John Mafera; asandoval@cartayaandassociates.com
Subject:
RE: Marathon Car Wash - RFI-01
Attachments:
doc07275220190423095253.pdf, S4.03.pdf
Team,
There is plenty of room to add the 1.625" split face shell to the edge as shown in the attached sketch and have a
minimum 4" bearing need for detail 3/S4.03. Detail 2/S4.03 is also ok to add the face shell. In either case there is no
need for an angle support. Please proceed with the response to RFI.
Thanks,
Transforming Today's Ideas into Tomorrow's Reality
Engineers & Planners
5555 E. Michigan Street, Suite 200
Orlando, Florida 32822
Office: 407.599.1122
Cell: 407.256.3716
Fax: 407.599.1133
LDelverme ayconinc.com
mail in error and that any use dissemination, # ! •. printing, or ! ! • of , prohibited
From: Mike A. Eckhardt <MEckhardt@mjinc.com>
Sent: Tuesday, April 23, 2019 8:30 AM
To: Juan Justiniano<jjustiniano@cartayaandassociates.com>; DelVerme, Luca <Idelverme@avconinc.com>
Cc: Joe Petzack <jpetzack@mjinc.com>; John Mafera <jmafera@mjinc.com>
Subject: Marathon Car Wash - RFI-01
Juan/Luca-
Shortly, you'll receive an email from a website called "WeTransfer.com". Within that should be a link to download a
copy of the Conformed Drawings and Specifications for the Marathon Car Wash.
Attached is RFI-01.Once you download the drawings and specs, can you take a look at the attached RFI?