26th Change Order 11/04/2007 MONROE COUNTY / ENGINEERING /FACILITIES DEVELOPMENT CONTRACT CHANGE ORDER PROJECT TITLE: CHANGE ORDER NO: 26 Freeman JusWe Center Jackson Square INITIATION DATE: Various Key West, FL CONTRACT DATE: June 16, 2004 TO CONTRACTOR: COR #40, 53, 67, 69 The Tower Groug,Inc. 405 SW 148 Avenue Suite One Davie, FL 33325 The Contract is changed as follows: The original (Contract Sum) (Guaranteed Maximum Price) ........................................ $13,804,000.00 Net change by previously authorized Change Orders ................................................ $1,733,044.84 The (Contract Sum) (Guaranteed Maximum Price) prior to this Change Order was ......... $15,537,044.84 The (Contract Sum) (Guaranteed Maximum Price)will be (increased (decreased) (unchanged) by this Change Order.................. $ 63,645.33 The new(Contract Sum) (Guaranteed Maximum Price) including this Change Order is ... $15,600,690.17 The Contract Time will be (increased) (decreased) (unchanged) by .................. ( ) N/A The date of Substantial Completion as of the date of this Change Order is ..................January 25, 2007 Detailed description of change order and justification: Re-route rough Plumbing to incorporate ADA requirements and relocate cabinetry and sink from room#2020 to#2024 S12 336 01 Furnish and install carbon monoxide monitoring and ventilation and motion controlled lighting circuits for the peffthy garage 40 86136 Adahtiona►elecfr►cal requirements for AnMPowermdage Entrapment Option (APE)for elevators. 3 970 86 Install door frames which are manufactured to receive security hardware upgrades 6 47710 Total 363 This Chancre Order is .46%f the odainal contract amour Not valid until signed by Owner Construction Manager and Contractor ARCHITECT: N/A r Date CONTRACTOR: The-Tower Group DIRECTOR, FACILITIES DEVELOPMENT: Date COUNTY ENGINEER: .` I Koppel, E. orate COUNTY ADMINISTRATOR /Z�_ A/k Thomas Willi/Debbie Frederick-pepu.ty Date i i k Change Order Attachment per Ordinance No. 004-1999 • Change Order was not included in the original contract specifications. Yes® No If Yes, explanation: • The Original Designs needed to include ADA requirements. • The CO Monitoring and Ventilation and Motion-controlled Lighting Circuits for the parking garage were made necessary by the grade conflicts identified. • The Anti-Poweroutage Entrapment Options (App was specified in the original specifications,but were not included in the electrical drawings. • The replacement of hollow metal door frames was approved on Change Order No. 12, and this is the labor to prepare the inside of the frames for installation. • Change Order was included in the original specifications. Yes❑ No If Yes, explanation of increase in price: • Change Order exceeds$25,000 or 5% of contract price(whichever is greater). Yes❑ No If Yes, explanation as to why it is not subject for a calling for bids: • Project architect approves the change order. Yes❑ No❑ If no, explanation of why: The Architect is not required to approve Change Orders for the Freeman Justice Center. • Change Order is correcting an error or omission in design document. Yes®No❑ Should a claim under the applicable professional liability policy be made? Yes® No❑ Explain: The initial rough plumbing design did not include ADA requirements. ' -h(--', Tower Group, In( C"A NGE ORDER REQUEST 405 SW 148 Avenue No. 00040 Suite One Phone: (954)476-3200 Davie, FL 33325 Fax: (954)474-3111 TITLE: Plumbing Mod's for ADA Cabinets DATE: l l/l/2006 PROJECT:Freeman Justice Center (FJC) JOB: 0417 TO: Attn: Clark Briggs CONTRACT NO Monroe County Facilities Development `i' �� 1100 Simonton Street Key West, FL 33040 - Phone: (305)295-4306 Fax: (305) 295-4321 RE: PCO To: TTG From: WEATHERT Number: WT005 DESCRIPTION OF PROPOSAL Change Order Request(COR)#40 addresses the costs to re-route the rough plumbing to accommodate revisions by CSA Architects to correct ADA violations in the Gonzalez Architects designs for Rooms#1022,#1030,#1039,#1047,#2019, #2029&#2034,and to relocate the cabinetry and sink from Room#2020 to Room#2024 at the request of the 16th Judiciary Circuit. The room modifications are shown attached as follows: Room#1022-pp.2&3 Room#1030-pp.4&5 Room#1039-pp.6&7 Room 41047-pp. 8&9 Room#2019-pp. 10& 11 Room#2029-pp. 12& 13 Room#2034-pp. 14& 15 Room P-2020/2024-pp. 16& 17 Door and partition changes were addressed previously in the Security Upgrades proposal, Contract Change Order#12. The value of COR#40 is based on Weathertrol Change Order Request#04-790-0009,revised 10/30/06(attached,pp. 18-21). We request a Change Order to increase the Contract Price$12,336.01 and no change to the Contract Time for this Extra Work. Item Description Stock# Quantity Units Unit Price Tax Rate Tax Amount Net Amount 00001 Plumbing Modifications 1.000 LS $11,614,58 0.00% $0.00 $11,614.58 (Weathertrol COR #04-790-0009 less sales tax) Unit Cost: $11,614.58 Unit Tax: $0.00 Unit Total: $11,614.58 Subtotal: $11,614.58 Description Markup Percent Markup Amount Sales Tax $140.70/ Profit 5.000% $580.73.,-' Total Cost: $12,336.01 E o Ln = " - - ,. mruuu�mru� uiuu�uirr�r ' V Ln Of INC I Of Al ^ I ^ 119 4T r N c� sAM�WUAAAIAAAIAAAAA -__ 7.NMIAA ,� +AwAArIAAAAAA. ,�.tiirwwAAAAAI�AIA s _ - - II II C ra 0 rQ' 3 C f Ln �� N NIM CD 0 9 N I W • 0 iroauiri Lij Ln Lj CN 0- CL I N d- E 00 ry 00 N I s N � � ® Ln W 0 I , __j Ll t 011 000' 0 ::D i y { 01 0291 CY) w o 75 2 ' A \c I W Ln - • � - Ljj t O } CL 1 _ ^ .�I�r�iiiiw.a .., Illl�i�■ICI 0 H NIH N I A i -r i NI I MCI- I lZr I � (01 uo 0 � w � � J 0o M LOo ■ " � - ` � r� it ry, � m N = N W � Q O CCU N Ln qi�' to 11 My w An l 2 � d- � ® o c LO I l � Cf) v , r e r Q /'1 Ln I 1 I u C CIA CD Qo 16 CD C l s tee..✓ _-_. N�' I III N 1 II � L N 0.00 ry O o N - � L r.T m 3 U C 71 Q � � Q W � WW � Q � W n U � U � N m W < O n-- N 0 - 00, 100, rj x U W d Q L_►_ � t N J � N � ce CN I C onn�wuw �n�uu�iuurnw - ,�.,r■w..� V�IIIIIVUIIV�IIQ U� 1 00 �✓ � LL— (46 c� ow 00 N N � Q � N of 7 , O N N Q � d- 1L ry ® r-q I D ® O N a� c� I N I rr - II � I I I -- - I - � I �� N 7 64 H H ELEC.� ROM. 2S. � 2063 -coGRAND 2163 { JURY 2020 71 i S CURITY —X > H OFFICE o ' I 2062 0� I i I < 9 -81) 11 '-211 5-3" 5'-9" 6'-10" -r H � I - SIM 2124 18' JUDGES' o H ol I \ CONFERENCE L , ROOM/VIDEO VES IL . EIS 2024 2021 _ 2123 ' W. H W.C. , W.C. EL) 2026 °O 023 2022 '-H— � L SIM H 2126 SI SIM 1 Cam- t4 'Pa I� - ;7A c�2A ywc-," "AQ ,o2_ p�M 2v10 v U U 2065 - - - - 21E 2164 ELEC . C � ROOM 2S , 2063 GRAND 0 — JURY J 2163 0 SECURITY _ OFFICE ;��ay, �x JUDGES 2124 CONFERENCE ROOM ' 2024 2125 EST 2123 W . C . . , W . C . � 2026 W . C . 2022 i � • 2023 0 , 2126 n f MAY. )V, LVVU L- LJfIV ]TV. 4VV CHANGE ORDER REQUEST weathertrol E] Change Order Request#: 04-790-0009 �..+11+•+li DU.f DI.IiO+ �����/fJ �� Project: Freeman Justice Center Project#: 04.790 To: The Tower Group Q Freeman Justice Center From: Weathertrol Attn: John Chandler Hector J.Ruiz 500 Whitehead St. 500 Whitehead Street Key West,FL 33040 Key West,FL 33040 Ph.: (305)298-2521 Fax: (305)298-2587 Ph.: (305)908-1000 Fax: (305)908-1039 We hereby propose to make the following changes; Plumbing Modifications in Hearing, Jury, Break and Conference Rooms Change Order Price --$48,05 This price is good for 0 days. If conditions change, this price Is void, We are requesting a time extension of 0 days in conjunction with this change. Hector J, Ruiz 5/30/2008 Author Date - (� Accepted The above prices and specifications of this Change Order request are satisfactory and are hereby accepted. All work to be performed under same terms and conditions as specified in original contract unless otherwise specified. Authorized Signature Date of Acceptance Iiih . JV• LVVV t. LV. -- -- - CHANGE ORDER REQUEST SUMMARY Project: Freemen,Justice Center COR#: 04-790.0009 Subcontracts [subcontractor oesoption Total TaicO Plumbing Miscellaneous Rooms Plumbing Modofocations 4 Subtotal $11,241.98 Total Cost (ke,6 S f&.,-,) —$O:8 i ic�,l - Sv Subcontract V4444-.O $ (( 106 1 •9U Markup Subcontract .. ggg } 553. ob 5des Tat, Total r c 44, p�. lq r 3054551390 TASCU PLUMBING Cr' 04:52 38 p.m. 08-26.2006 2 r3 NOWL 301 East 10th.Ave. M ,�Order# 4 U- TL-0-5 Hialeah FL 33010 Propos�ll # coo4-os2ao6 Phone 305.45S.1377 ait�rrrao coy+ o�aTivry Fax 30S,45S,13% Date 5124/2006 CUSTOMER: Status PENDI Weathertrol Malntenanee Corp. 7230 NE 4th Avanuc Date Approved PMDLN0 Miami FL 33138 PROJECT: 262-P/Freeman Justice Bldg.(PLBG) DESCRIPTION OF WORK TO BE PERFORMED: Total Change Order Plumbing modifications in Rming Rooms,Jury rooms,Break room tier Conlbrence Roam. e H arine Ltooms: #1021,01048,112018&k2033 s(Wa-4 •Jury Roomy if 1022,N 103%41039,#1047,82019 tit 1034 Sinks-8 +B=k Room:NM9 Sink-I •Contt rence Room:#2024 Sink-I ToW Sinks -14 Relocate 14 sinks(ncludinw. r 1-Remove exiatiag sanitary drain in rooms 91021,41048,01022,01030,41039 and 01047. 2-Make (6)2"doles with core 3-Piro Stopping for(6)2"holes 4-New Sanitary Draia and Vent;Rcloosto Materials: Qty. Materiels 2W 2"PVC Piping 20 2"1/4 bend 14 2"1/8 bend 16 2"San Tee 14 2'Test Tee 32 2"Swivel hangers 100, 3/4"Type"L"copper 12 3/4"Copper hanger M#o Ah 840.00 10%Mark UP 84.00 Tax 58.10 r p� -982 80j^� Ad CoreDril! 5g.i �v 1,170.00 SUBTOTAL, 81.90 - .-251.9e Lodging 2,746.00 Travel 225.00 Total Change Order ACCMANCE OF CHANGE ORDER The prices,specifcatlons,payment terms,and condition#stated on this change order arc satisfactory and are hereby accepted. Two Plumbing Corporation It 10horiaed to do the work ns speeillod. t3igttatare nste_,/� Mr dknrwm x devLGee�eon d•Aov.pedAe�d i�olKy ua.ea4+ap1 t»eaowd ay qo"w4w wdw as.a eaon»M ran h4 bqs err gwo1.rMrad eww k WOOM M•gar 34 Jqs r TAM ftmft` c s N Wi fofaa �N"'Rnl'anW�v►a�raa.m�du��or Pape 1 MA'. )V• LVVV L• LVI III - 105455*1306 TASCO PLUMBING C; 04:F`05 p.m. 05-26-2006 313 ar,E >I 301 East 1Oft Ave. Chat►,je Order# 4 W--Fcf�S Haigh FL 33010 proposal # 0004-032406 Phoae 30S.455.1377 Fax 305.455.1396 Date 04I2006 CUSTOMER: Status M01 wuthemol Matntenanoe CoM. Date Approved PEND[NO 7250 NE 4th Avenue Miemi FL 33138 NOMENO PROJECT: 2624/Fr"man Justlee Bldg.(PLBG) DESCRIPTION OF WORK TO BE PERFORMED: Total Change Order Meal 3mea#30 per day 1br Two wocks 900,00 Add Pica Stopping 68•oo Labor 140 bra&25.00 3400.00 42%Labor Burden 1,470,00 1 Total Change Order ACCEPTANCE OF CBANG9 ORDER The pricm speeiticadoaa,payment terms,aad coodltion stated on this change order are sattshetory and are hereby accepted. Tries Plumbtns Corporation Is aathorlud to do the work ns specified. Signature Date--JJ kg 9L-Woa er der44ors slew 114 dow oN hwH4i{man 0014W vwAW say qu w*n e v wid A Www an on"p wr W drone*i a*nft All ynowo ca*kfW%irm mike.Ud""m id"MNnd W rAwd pmFew Mq kwlbt m aer filer 10 tj n Tees ftniaa commlic"#";a. Pop 2 C6..-24 9f�-�-11 HP OfficeJet 7210 Log for Personal Printer/Fax/Copier/Seari,jer The Towel Group 305-296-2587 Nov 01 2006 11:16AM Last Transaction Date Time TVDe Identification Duration- Paces Result Nov 1 11:09AM Fax Sent 15612438184 6:37 22 OK The Tower Group, Ind._ Cf iNGE ORDER REQUEST 405 SW 148 Avenue No. 00053 Suite One Phone: (954)476-3200 Davie,FL 33325 Fax: (954)474-3111 TITLE: Parking Garage Exhaust Fans DATE: 11/20/2006 PROJECT:Freeman Justice Center(FJC) JOB: 0417 TO: Attn: Clark Briggs CONTRACT NO- Monroe County Facilities Development 1100 Simonton Street Key West,FL 33040 Phone: (305) 295-4306 Fax: (305) 295-4321 RE: RFP To: TTG From: CSA Number: 9/8/06 DESCRIPTION OF PROPOSAL Change Order Request(COR)#53 addresses the cost to furnish and install CO Monitoring and Ventilation and Motion-controled Lighting Circuits for the Parking Garage. This COR was requested via RFP from CSA Architects,dated September 8,2006. The changes addressed by this COR were made necessary by the grade conflicts initially identified by TTG in RFI#9,dated November 9, 2004,sent to Gonzalez Architects(GA). The grade conflicts could not be reconciled,so CSA Architects furnished a retaining wall design(Re: TTG COR#15)and closed the parking garage exit with a louver(Re:TTG COR#16). These changes necessitated added ventilation. COR#53 is based on Weathertrol Change Order Request#04-790-0020(summarized as PCO#WTO11,copy attached),and TTG breakdowns for the electric work(copy attached). Please issue a Change Order to increase the Contract Price$40,861.36 and no change to the Contract Time. Item Description Stock# Quantity Units Unit Price Tax Rate Tax Amount Net Amount 00001 Exhaust Fans,Frame,Hood& 1.000 LS $20,428.89 0.00% $0.00 $20,428.89 Isolators less tax(Re:PCO #WTO11) 00002 Power&CO Monitor for Fans- 1.000 LS $11,343.37 0.00% $0.00 $11,343.37 Labor&Materials less tax and burden. 00003 Motion Sensors-Labor& 1.000 LS $3,300.91 0.00% $0.00 $3,300.91 Materials less tax and burden. Unit Cost: $35,073.17 Unit Tax: $0.00 Unit Total: $35,073.17 Subtotal: $35,073.17 Description Markup Percent Markup Amount Sales Tax - Item 00001 $798.00 ✓ Sales Tax - Item 00002 $700.83 Sales Tax -Item 00003 $175.49 Burden - Item 00002 $1,099.41 Burden - Item 00003 $528.58 5% Overhead- Item 00002 $567.17_ 5% Overhead - Item 00003 $165.05 Profit 5.000% $1,753.66 Total Cost: $40,861.36 Weathertrol Mainteii_ Ace Corporation P )POSED CHANGE ORDER No. WTO11 7250 NE 4th Ave. Phone: 305-908-1000 Miami,FL 33138 Fax: 305-908-1039 TITLE:Fans for CO Monitors DATE: 11/14/2006 PROJECT:Freeman Justice Center(FJC) JOB: 0417 TO: Attn: John Chandler CONTRACT NO;-0417-004 The Tower Group, Inc. - 405 SW 148 Avenue Suite One - Davie, FL 33325 Phone: (954) 476-3200 Fax: (954) 474-3111 RE:RFP To: TTG From: CSA Number: 9/8/06 DESCRIPTION OF PROPOSAL Add Exhaust Fans EF-9,EF-10,EF-11 &EF-12 per TYEC Drawing#M-1,dated 8/10/06(Re: Weathertrol Change Order Request #04-790-0020,dated 11/14/06. Item Description Stock# Quantity Units Unit Price Tax Rate Tax Amount Net Amount 00001 Subcontractor furnish and 1.000 LS $19,456.09 0.00% $0.00 $19,456.09 install fans,frame,hood and isolators less tax Unit Cost: $19,456.09 Unit Tax: $0.00 Unit Total: $19,456.09 Subtotal: $19,456.09 Description Markup Percent Markup Amount Sales Tax $798.00 Profit 5.000% $972.80 Total Cost: $21,226.89 By: By: Hector Ruiz John Chandler Date: Date: Expedition CHANGE ORDER REQUEST , weathertrol ® Change Order Request* 04-790-0020 MwfMfi f•w NG[CO�l Ow..Ow Date: 11/14/2006 Project: Freeman Justice Center Project 04-798 To: The Tower Group @ Freeman Justice Center From: Weathertrol Attn: John Chandler Hector J. Ruiz 500 Whitehead St 600 Whitehead Street Key West,FL 33040 Key West, FL 33040 Ph.: (305)296-2521 Fax: (306)296-2587 Ph.: (305)908-1000 Fax: (305)908.1039 We hereby propose to make the following changes: PCO#2 dWg M1 revisions Change Order Price �28;36f3� This price is good for 0 days. If conditions change, this price is void. We are requesting a time extension of 0 days in conjunction with this change. Hector J. Ruiz 11/14/2006 Author Date Accepted The above prices and specifications of this Change Order request are satisfactory and are hereby accepted. All work to be performed under same terms and conditions as specified in original contract unless otherwise specified_ Authorized Signature Date of Acceptance rTWI nncr I tT"fT I L."M Iu(fI n'].nr nn fr rr CHANGE ORDER REQUEST SUMMARY Project: Freeman Justice Center COR#: 04-790-0020 Subcontracts Subcontractor Description Total Elite Ductwork Add EF-9,EF•10,EF-11 &EF-12 systems ,All W Subtotal Total Cost Cost $0.00 Subcontract Sismi i.fig. j o), Markup Subcontract 4W,g,� Tota• CCATorACf'.r11C !Nt 1 AITM.1 'TOUT U31.11 F7'JAt_I.V U.7 C 7'01T 00 -IT-TT O O M 000 O LO 00 0 000 O O O r M r M N O NNOOtitDOtootnOOOOOtD OOet CR d I� G C tp N ti CV d h O O O G O M CO OD � O 0M CV O n r w v► w 40 O H 0 W W2UWUWgWw000OOW 2Nv�i F- O O O O O O M O M O O M O O O O O O ONOOe- 01ClONM00000A� F- �! rC70r � Y� OOOOOOC/ O P 0CDtD0NN tOOONO0 � 1�- OtONrOlO O! Ow t� N4J000M1� erOMeGONr00 r t� IA d9 00 C� N 1- 0 M N M W 0 W H � �A aN� Q? N {fitf!Vi4Y446R 01 JJJ U ai w m � J U w J � W H Z W lwlu N- O O O to O O pp r N 00 O et W tD O WlNO rrOratM00rON U OMO NONNh �� N0w rwOOM r- I.- w0w0 le tD 40rrrrrMN401-44 clNr a v► www .r►w "w 40aa40e9. a N H� �►- � -L = vp =Fw- OU cl-i �U0WZn vwUa= v�►v-� O �N 'WW Z _3ozR wO oyZWmOvn nwavo U 0 t w — t C.) * Oa. i 2mzawWxK5wOtu z ~ =Lw WgOLMx U. O U M M W W t W w t W t W W w W w W w w o O d � LO M M Ln d el' � split AC Current Switches CS-AC-1s Input. F5 to 150 Amps AC Continuous Output: Normally Closed or Normally Open SSR, 1.5 to 150 A Setpolnt ® Self-Powered 0.15 Amp Solid State Switch _ C U�. US • just i.5 to 150 Amp Setpoint� �® LED Status Indicator - Ai. CE ModelsRanges CECS-AC-1 + ". Normal Closed(NC) t Switch pens when setpoint is exceeded II Solid state switch:0.15 Amps max 0 130 VACNDC CS-AC-2 Normally Open(NO) Switch closes when setPo Int is exceeded Solid state switch:0.15 Amps max®240 VACNDC Specif ications Output Magnetically Isolated solid state switch - . Switch Rating N.O.version:0.15 A®240 VAC or VDC N.C.version:0.15 A 0 130 VAC or VDC Not polarity sensitive Off State Leakage None Features Setpolnt Range t Description — 1.5 to 150 A The CS-AC series Current Switches consist of a current transformer,signal con- Setpoint Adjustment ditioner, and limit alarm in one compact package.The CS-AC series products 11 turn potentiometer are self-powered,operate over a wide frequency range,and contain a universal solid-state output that will trip when a field adjustable setpoint is exceeded. Hysteresis The CS-AC series are designed to withstand harsh Industrial environments. Approximately 5%of setpoint They can be mounted in virtually any position and either panel mounted using Normal Indication the built-in mounting bracket or hung directly on the wires and secured with a Red LED flashes once every 2 to 3 seconds for normal operation wire tie.The split core case design makes Installation In new or existing applica- Alarm Indication tions very quick and easy since the product can be snapped shut around the Red LED flashes 2 to 3 times per second when switch Is tripped wire to be measured. Response Time The built-in current transformer physically isolates the high current from the limit 120 milliseconds alarm circuitry making this product much safer to use than other products or methods.In addition,it eliminates the Insertion loss that exists when shunts are Frequency Range used, 50 to 100 Hz Configuration and installation are simple.The switch is powered by the Induction Overload from the line being monitored.The AC current is measured by the built-in cur- 150 Amps continuous rent transformer, eliminating the need for both power and input wiring. Once 400 Amps for 6 seconds installed around the wire to be measured,only two wire connections are neces- 1000 Amps for 1 second sary for the solid state output. Isolation Voltage The setpoint of the CS-AC Is user adjustable from 1.5 Amps AC to 150 Amps UL listed to 1270 VAC AC by turning a potentiometer. Tested to 5000 VAC Two models are available.The CS-AC-1 includes a"normally closed"solid state Power Supply output and the CS-AC-2 a "normally open" solid state output. Both models None,self-powered include a status LED that flashes slowly if the setpoint has not been exceeded Sensing Aperture (non-alarm condition) and flashes rapidly if the setpoint has been exceeded 0.85"x 0.85"square(21.5 mm x 21.5 mm) (alarm condition). Case UL 94V-0 flammability rated Environmental p 0D. T ROAar —4 to 122 IF(-20 to 50°C),0-95%RH,non-condensing JCS,/ Listings INSTRUMENTS LIMITED UL&CUL 508 industrial control equipment,CE certified 1 Delta Park Blvd#12 Dimensions Brampton,ON L6T 5G1 Width: 1.19"(30.2 mm) 905457-6322 or 800-794-5883 Length: 3.53"(89.7 mm) www.mod-tronic.com Height: 2.470"(62.9 mm) 0 Absolute Process Instruments,Inc.1 IX4 LoopTracker—Reg TM Absolute Process Instruments.Inc. RInstallation and Setup NEI DESCRIPTION OUTPUT WIRING The CS-AC series are solid-state current operated switches. Connect control or monitoring wires to the sensor. The CS-AC-1 Is a normally closed(NC)switch.It opens when the current level Use up to 14 AWG copper wire and tighten terminals to 7 inch-pounds torque, through the opening exceeds the adjustable setpoint.This makes It useful when Be sure the output load does not exceed the switch rating. detecting a drop in current such as a heater break. The CS-AC-2 Is a normally open(NO) switch.It closes when the current level CAUTION:Incandescent lamps can have"cold filament inrush"current of up to through the opening exceeds the adjustable setpoint.This makes it suitable 10 times their rated amperage.Use caution when switching lamps. when detecting a current increase such as a motor overload. A or DC AC or DC The internal circuitry is totally powered by induction from the line being moni- Power Alarm,Indicator, Relay,etc. toyed.The solid state output contacts,can switch AC or DC. INSTALLATION To Open o x x o Ap; CS-AC-1 or CS-AC-2 2. Swing open SETPOINT ADJUSTMENT The setpoint Is adjusted with the 11 turn potentiometer.The pot is shipped from the factory set fully clockwise(CW)to the lowest setpoint.Turning the pot count- er-clockwise(CCW)will increase the setpoint.The pot has a slip-clutch to pre- vent damage at either end of Its rotation.To determine where the adjustment is, 1. Push tab turn the pot all the way CW.This will return it to the minimum setpoint. towards hinge We recommend adjusting setpoint to allow for usual utility company voltage variations of 10 to 15%. Checking Output Status IMPORTANTI 1. Output contacts are solid-state.Check output status by applying voltage to Keep contact areas cleanl the contacts and reading the voltage drop across the contacts. An Press the tab in the direction as shown to open the sensor. Ohmmeter set on°Congnuity"will give misleading results. Typical Adjustment After placing the wire in the opening,press the hinged portion firmly downward 1, Turn the pot to minimum setpoint(11 turns CW), until a definite click is heard and the tab pops out fully. 2. Have normal operating current running through sensor.The output should be CS-AC switches work in the same environment as motors,contactors,heaters, tripped since the pot is at Its minimum setpoint.The LED should be flashing pull-boxes,and other electrical enclosures. fast(2 to 3 times per second). They can be mounted in any position or hung directly on wires with a wire tie. 3. Turn the pot CCW until the unit untrips.This is indicated by the slow flashing Just leave at least one Inch distance between sensor and other magnetic of the LED (once every 2 to 3 seconds),or by the changing of the output devices. switch status. KEEP SPLIT-CORE CONTACT AREAS CLEANIt 4. Now turn the pot CW slowly until the unit trips again.It Is now set at the cur- rent level being monitored. Silicone grease Is factory applied on the mating surfaces to prevent rust and A. To set UNDERLOAD—Turn the pot about 1/8 turn further CW. improve performance.Be careful not to allow grit or dirt onto the grease in the contact area.Operation can be impaired if the mating surfaces do not have good B. To set OVERLOAD—Turn the pot about 1/8 turn further CCW. contact.Check visually before closing. MONITORED OUTPUT OUTPUT LED AMPS CS-AC-1 NC CS-AC-2 NO None or<Minimum CLOSED OPEN OFF 2'mm Below trip level CLOSED OPEN SLOW(2 sec) 0 n" Above trip level OPEN CLOSED FAST(0.5 sec) n __�3./mnn °r i TROUBLESHOOTING Sensor Is always tripped 1. The setpoint may be too low.Turn pot CCW to Increase setpoint. z.z5" ---------- 2. Switch has been overloaded and contacts are burned out. Check output r 57 2'""0.857" load, remembering to Include inrush on inductive loads(coils, motors, bal- 21.1rrm lasts). 0.175" Sensor will not trip 3.2trttn 1`35 1. The setpoint may be too high.Turn pot CW to decrease setpoint. P=MM ❑ 2. The core contact area may be dirty.Open the sensor and clean contact area. 0.854" t190 3. Current Is below minimum required.Loop the monitored wire several times 21. l 3.53' through the aperture until the"sensed"current rises above minimum. Sensed Amps=(Actual Amps)x(Number of Loops) mm Count loops on the Inside of the aperture only. 4. Switch has been overloaded and contacts are burned out.Check the output I 1I I ..T4.5nm of 2 im.dla. load.Remember to include inrush on inductive loads(coils,motors,ballasts). 0 L 1l g MOD- T P" P�Q /C 3,044 INSTRUMENTS LIMITED 1/.3mm 1 Delta Park Blvd#12 PI maintains a constant effort io upgrade and improve its products.Specitications� Brampton,ON L6T 5G1 are subject to Oar,ge wittout nice.Consult taciory fo,you,npedfic regolrenwnts. 905457.6322 or 800-794-5883 www.mod-tronic.com COR- S-AIR 1!.Nt CORSON AND A O I TES,INC. zeao aw 301n 10E Nurw 2�229 ►l"MO<PArK FL =00 WWI 11164-W,4X 1 FL wafaC;eoo.crs adaLA Fax YfA�d6OrOt2I Col.F-26A-46A.4143 printedJ 8/2112J08 ts-blall;irha�Wrlvir.ear+/Wobiwvv+.00rt•air.com Pace: 1 of 1 Phone; 306-266.1'S21 Yu: THE TOWER GROUP F;x; 305-226.11 eT Aim: JOsE CLAUSELL Ncn4 a t_mA��oNl T Rni to rn OUCIT �, A�tavtLnaoN: OTs AM n o oAT a AI "ARI OS •. IPNBlA _ __ __•.... r,. 1 LOT PRICE MCI.UDE.S-d-f:0 MONITORS,4 POWER SUPPL.IPS, Op(pon: NOT•'E:YOU DO NOT NEED A MAIN CONTPIOL PANEL TL)START ALL FOUR PAN$,NUT TI ICY WILL NEED SOMEONE TO INSTALL INTERLOOKINU RELAYS(SUPPI.IED 6Y OTHERS)IN I HE FlFI D. YOU MAY AI AO PURCHASE A SPEC4AL RE AY rK13.CONSiSTINd OF ENCa,OSURCS AND RELAYS FOR *AW.00. _ $4,74109 Due lo..ttt0 axtt a vvlatillty rtagardIng Meal and AluminumTproducW, the y�c ri tJClted in•'thb v saU uotatio is valid for the rwxt days. TNaa 0Uofl4pn L,SAM 4M THU J`%LOWMO M MS AMC CONW'0"' ■Fri �a I `I d Ths N a nwwma VkogM. Wa A�nx rAa0ara4 va Ivr nr0dd�,anasr«ba auanNHalf a t 4w";round faopM w 4eWn f+viOa «abaa ww"r.mm Ma+sat It al ww 044k to oeowraay. •TNt'@WtW A pavwa fOf aanaal�t%►.arary uraw edrarwke Hood ■Tt�alu+a VA e4lu fIm w"O I oquMlw• Doan AJIW a�oM eha4�40 or oanaoaMtloni pia noult�rkaMafN awiwn a ti arob�� t ,aaan ao MnMd uu Nm NMI AMAM•OAAC OOVH ry Prwiw+PbM4&Aim •Ford""(Iswoo to ar+all 10wW44 wm 0'w 4arnw rr#,4ablt044 on Mir orw wale WdICAru apPtlaalaon kr*w rAvayrwIt,Haw ow1111WA4. w Anow dayls)fw,karHr,wd• kW Allow w«�dll IAMM IOn 04f aAfr'irld aq►w01 and vuebm.r MuuL. A Coal(WA I W iT ba lawtW uWA f4wm of toodo*Amwt r"a obUlnMQ 4 AUA Vd TlY Do f A04 W a'*-c irq 44. TFRA19`a Knn,,Fall dAmai l0 9ouh�r4odo bdx%d abaa.t�"mmp And do lu Mraa*dws AIM qm �abm NwOrW AMAI N"*A U4 ft 0*1 Mek At,ruN I*hlW**Abletof � th aw W rud Wnvy OM' osaW 01 BAN eularW.?VMhfl=f Mlr"o b Poy Sa1AM adow Nn tM aYad WYrrwnt ID AN rrwdc,30 IMa albOrl,tha t�Gaf,Y tnt ApOd1 fltay(YRa7Yn Said nWarOC and IdN Pa bra toad, rtouMwM iltO 0s faao wn!W W m VAWA ow"QA of vry 41W WnN of nu rprw 1011,►ure}+atu prate+ oenral i1dr +nAv�a[tales MCor4r 1am1�� Irrr formp or osk7f p4um DY 1aDea.foalawb,NrO,FaN,fs wet, pay N4a t toy.NW hA am url 40 4*daNd duoyoa sA wwea u to o wym apace NM&$No!Mf/rtMufitWnA fd rofwaww+a ow Cur�irnl ohm Ammon.Vw PlAclrarr rrgrrm b�y. Y om undo WR mrooaY4A4 ul.ordara olaead W*t NOOOM40CL TM Punlhal4af rank OIt m t QW v(arts Ndlm d ODa+rtonaa rtnad ffld aA HOOM kw�fAuMct axlar b CaNsr oIOtSF'9 + Y.Pa Muddi Propaowl,LYJo VIM M-howl!iMd Mkfw P4(to thO rid IoM rhanf CankLL'4 TM1 enn is Wat�d q,n�MfMLfnO rwaa•. d ro ntiaf Co11�CG OdMr wniw+l OpIkM fraAa die abara daaaa-4w for usta snow PO ,and I"to wv auoh era vit"brumn ewer Tar thwf law" vAmm.l►roby mtvw to w0 a11rOyo M 'Ime ftWudin r0 u"of Wuu+�4nd Mbtrro,rilas wAwwad l all�othw p�raA W,L fi aWv+M Pf KMIS�aM a�iDtai O@"dtaext�raa.w by lghbo pw�voymm"must boamods w4wdImS to 10M,TWO Ousts w A p►opatat fnust Ds ahsroJ and farad book to our orf loa and dopcWil poll If appilesbls poor m uarrKQP ardorin4l utla pmdual on Yov or Your VQmPsny'a Daharf. �.0.N4Anaor Shp VA ArK+v"wd Chip Oata Amrovsa by Ihr10FfTAN1'yVOTf G'C fMR H4P0r1MPT K"OUAIRMT1ra0 W A S faoo OF-$IS III I(Ivl° ujAya Fpf�OM THE OATZ�{v DIWO oTATCH WW"L gxpmm wt�oMS ONPlwxr sa wry n I8ova TOTAL P.01 ` e TM CARBON MONOXIDE MONITOR MODEL CM200 SERIES TYPICAL APPLICATIONS: • Parking Garages • Fire Stations • Vehicle Maintenance Shops • Police Stations • Car Dealers • Post Offices • Warehouses • Ice Arenas GENERAL DESCRIPTION: TOXALERT'S Model CM200 Series monitors are compact, solid-state, low maintenance, cost effective carbon monoxide monitors designed for fixed installation, continuous monitoring. The Model CM200 Series consists of three separate monitors; Model CM201 has a single stage audible alarm; Model CM202 has two +R . stages of relay outputs, and Model CM203 has a first stage relay output and a second stage audible alarm. All models are microprocessor r1�rl' based with temperature and humidity CM202 compensation for stability. The solid state semiconductor-type sensor and associates electronics ensures trouble-free, long-term operation, for there are no pumps, filters or chemical cells to replace or maintain. FEATURES: • Self-Checking feature for sensor failure • User adjustable Alarm Level • Sensor LED indication • Operating range meets OSHA std. -Operation Normal - Power On 1910.1000 -Warning Stage - Alarm Stage • Compact Nema 1 enclosure • Completely solid state for long life • No maintenance except periodic • Relay outputs for control and alarming calibration checks • User adjustable Warning Level TOXALERT INTERNATIONAL,Inc., PO Box 159,Mound,MN. 55364 PHONE: (952)472-4541 • FAX:(952)472-4960 www.toxalert.com OPERATION: The Model CM200 series has a two color LED (light-emitting diode) to indicate its operating status. When the LED is flashing green, operation is normal and not in alarm. When the LED is flashing red, the unit is sensing CO above its setting. A continuous red or green indicates failure; and LED off indicates power failure. Model CM201 is a single stage carbon monoxide monitor with audible alarm. . A red LED and audible alarm activate when the concentration of CO exceeds the factory-set(user-adjustable) level. Model CM202 is a two stage carbon monoxide monitor with a relay output for each stage. If the CO concentration rises and stays above the warning stage setpoint (field adjustable) for a delay period of thirty seconds continuously, the warning relay, amber warning LED, and a three minute minimum on timer shall activate. The warning stage shall be activated for a minimum of three minutes and then deactivate if the CO concentration is below the warning stage setpoint. Should the CO concentration remain above the warning stage setpoint for longer than three minutes, the warning stage shall remain activated until the CO concentration falls below the warning stage setpoint. If the CO concentration should continue to rise above the alarm stage setpoint (field adjustable) and remain above the alarm setpoint for a period of ten minutes,then, the alarm stage relay and red alarm LED shall activate. Model CM203 is a two stage carbon monoxide monitor with a warning stage relay and an audible alarm with silence switch that is activated by the alarm stage. The operation is the same as the Model CM202 except that the audible alarm replaces the alarm relay. SPECIFICATIONS: • Sensor Type: Solid State Metal Oxide Semiconductor • Indicators: • Relay Contacts: 120 VAC, 2A resistive Amber LED for Warning • Factory Setpoints: Red LED for Alarm Model 201 - Alarm 50 ppm Flashing Green/Red LED Model 202 Warning 50 ppm, Power On - Microprocessor Operating Alarm 100 ppm • Audible Alarm: Model 203 - Warning 50 ppm, Model 201 - Sustained alarm tone for as Alarm 100 ppm long as gas is present Other Setpoints available Model 203 - Alarm horn with silence • Maintenance: None other than routine calibration push button check • Warning Stage Delay: 30 Seconds • Minimum Fan On Time: • Operating: Model 202 - 3 Minutes Temperature: -20 F to 122 F Model 203 - 3 Minutes (-29 C to 50 C) • Alarm Horn Delay: Relative Humidity: 5 to 95% Model 201 - 10 Minutes non-condensing Model 203 - 10 Minutes • Enclosure: • Range: 0-250 ppm Dimensions - 7 %"H x 5"W x3 3/8" • Response Time: Less than 30 Seconds (19.05 x 12.7 x 8.57 cm)Weight: - 3 Lbs.(1-3 kg) • Input Power: 12 VDC, 250 MA Type - Nema I Finish - Gray Enamel Material - Steel TOXALERT INTERNATIONAL,Inc.,PO Box 159,Mound,MN. 55364 PHONE: (952)472-4541 • FAX:(952)472-4960 www.toxalert.com E f INSTALLATION INSTRUCTIONS 1. INSTALLATION: CM200 SERIES CO CONTROL UNIT FIELD WIRING DIAGRAM Refer to Figure 1 and install and wire the �� ToXalert monitor as follows: AUXILIARY ALARM RELAY DRY CINITACTS-2 AMP MAX o CM 200 SERIES ICM 202 ONLY) 1. Locate a mounting location away C o SENSOR BOARD T2 from direct fresh air intakes, and j o 0 mount vertically on wall or support o column approximately five to six feet above floor. 0 2. Open door and remove circuit board 00M and sensor from enclosure. 00 0000 3. Mount enclosure with hinge along �0 left side by using mounting holes (4 are available). A wiring access hole must be added to the enclosure anywhere along the bottom or right O th (CM 2 2 A PAN RELAY N DRY CONTACTS- 2 AMP MAX (CM 0 AN➢ CM 203) side. Do not place an access hole on T3 I z a a 15 the hinged side of the enclosure, o T` o since, if conduit is used, this may O restrict the opening of the door. If INPUTH2 V POCCWER ON➢ conduit is to be used, use a chassis punch to match the required fitting Figure 1 size. 4. Remove any metal chips and burrs from enclosure CAUTION: Relays RI and R2 are rated for 2.0 amps resistive load. If a higher rated load is 5. Re-install the sensor and circuit being controlled, add a remote relay between board. R1 or R2 and the load. 2. WIRING UNIT: Refer to figure 1. 2. Model CM202 and CM203 —Connect controls- (i.e. fan), to R1 relay contacts. WARNING: To prevent Terminals TI-C (common) and T1-NO fire or shock hazard turn off (normally open) or T1-NC (normally closed). supply power and fan power sources before making 3. Model CM202—Connect load (i.e. remote connections. Comply with all alarm) to R2 relay contacts, Terminals T2-C local building codes and (common) and T2-NO (normally open) or ordinances. T2-NC(normally closed). 1.) Connect power to TB3 as follows: 4. Turn on monitor power source, but do not T3-1 (+12VDC) apply power to remote devices at this time. T3-5 (Ground) TOXALERT INTERNATIONAL, Inc.,PO box 09,Mound,MN. 55364 PHONE: (952)472-4541 - FAX:(952)472-4960 www.toxalert.com 3. BURN-IN Burn-In period allows sensor to stabilize before applying power to remote device(s) connected to models CM202 & CM203. 1.) Be sure power is off to remote devices and monitor supply power is turned on. 2.) Allow sensor to burn-in for a minimum of 72 hours with power turned on to monitor. Monitor may go in and out of alarm during burn-in. 3.) When 72 hours have elapsed, confirm remote device(s) wiring and turn power on to remote devices. 4.) Status LED flashes on and off to indicate normal operation. If LED is on solid green or red; please contact your local representative or TOXALERT INTERNATIONAL, INC. for servicing. ORDERING INFORMATION: CM200 SERIES CARBON MONOXIDE MONITORS Model No. Description M 201 Carbon Monoxide Monitor with sin le stage audible alarm. CM 202 Carbon onoxide onitor with warning output relay and alarm output relay CM 203 Carbon Monoxi e onitor with warning output relay and alarm stage audible alarm with silence switch. OPTIONAL POWER SUPPLIES FOR CM200 SERIES: Model No. Description CMP12P AC Adapter, 120VAC to 12VDC lA egulated Plu -I CMP12U Power Supply, 120VAC to 12VDC 300mA (Regulated), Unit Mounted CMP 12M Power upp y, to DC @ 1.7A (Regulated), Nema 1 Enclosure (for up to five units). -- � 2" �3.375"� .75" 75" FRONT SIDE CM202 S WITH FIG. 2 VClJNT!NG DIMENSIONS CMP12U POWER SUPPLY (MOUNTED) TOXALERT INTERNATIONAL, Inc.,PO Box 159,Mound,MN 55364 PHONE: (952)472-4541 • FAX:(952)472-4960 www.toxalert.com f O O N O O O O O N 0 0 0 0 M OD W Qf h 0 tf) N O O N ill t0 O t0 O m � � 000VTOIfJMCVOOOO � tANMV_ O g � M ' w N 'i VT b9 H 0 H f- to O = W W � UW C.) W2 W W0000 = w � F- O O: O �LoA No� oOOoNu� ou) OotnOoOO M O tV .4[7 uiC 0 0 0M000 O ZNC M000 � B h 00 MhN V WW NN � � OOO � cn CY) V►Vii/l �A MfNA ��VYVl Ir l M Q N m V 40 � g 0 W p J w 1— z wwUc� wt� wgwt� t� c� 'Diu 1_ O t.- O CD O W W O W O -: to e- �Q cl O 4 � i A ww�40 44 40 Vk44 N Z O C W � ZOZtn y vwzWVZ -J' wNNaw � d Ix J Z W 0m1- OVZ _ OVNWW00zC.) n U) W za 0vv0 000U0 vwi ~ oIL uj0Zox � � ~ w Z = LL 0 e� F' � W Wn. 1— :304 M M � evM 0 M M M W W �y W W W W W w W W W L M . *0OD The Tower Groff), f..% .QUEST FOR INFORMATION 405 SW 148 Avenue No. UU23o Suite 1 Phoce: (954)476-3200 Davie,FL 33325 Fax: (954}474-3111 TITLE: parking/outside lights DATE: 7/27120()6- PROJECT:Freeman Justice Center(FJC) JOB: 0417 TO: Attu: Hank Goldman Currie, Sowards,Agui la Archite= _. 134 N.E. 1st Avenue STARTED: Delray Beach,FL 33444 COMPLETED: Phone: 561-276-4951 Fax: 561-243-8184 REQUII2ED: 813/2006 REQUEST: I need to know if all the fixtures in the parking garage will be on 24 hrs/day and 7 days per week or if some of them will be turn off at night time. According to the contract drawings there are no light switches for these lights. Also please provide information on how the outside lights will come on,there is no timers,lighting contactors or photo cells listed in the contract documents. Requested B3'= Tower Group,Inc. Date ? '1-7 Signed. Jose I! ANSWER: �N l� 4'GUCfC jW1771�-61 ���'%/O/>✓ �S��v50� 'r2 5' ,4 i �1Ci� t"Air"1 /D//v1- Xc-7 4,(- �X ,��/G f� G! C��tTs AucWered By:>C7 ,ZSa Aquila Architect Signed. Hank Goldman JOB NAME: L I G "H T I N G DATE. TYPE: LOS2400/277 _ DESCRIPTION 360°view Super Ceiling Sensor with integral 20 amp power pack.No extra wires to run or extra boxes to install. Covers 2000 sf @ 9' height. LED detection indicator. SPECIFICATIONS DIMENSIONS Easy Installation: Color: Relay and sensor all in one reduces White installation cost.Compatible with dimmers Weight: and electronic ballasts.LED testing and 0.55 operation indicator. Maximum Reliability: Adjustable detector sensitivity for superior detection. Maximum Maximum Versatility: Adjustable time delay.Sensor detection pattern can be customized.No minimum load requirement.Can be wired in parallel. UL Listing: For indoor applications.Tuff Dome&Smart Box are UL Listed for wet locations. Adjustments: Time Sensitivity Coverage Area: 2000sf @ 9' Detection: 360°view Super Ceiling Sensor Fluorescent Watts Switched: DETECTION PATTERN 4800 watts Incandescent Watts Switched: 4800 watts Manual Switch: 5d, Override key Patents: RAS sensor and fixture designs are protected under U.S. and International Intellectual Property laws. Power Consumption: Negligible I Ratings Amps Horsepower: -- - - 20 amps 1.5 horsepower Top View 50' Time Delay: 6 to 15 minutes Note•Spociflrations may change without notice RAS Lighting, Inc. • 170 Ludlow Ave- htorthvale. RJ 07647 • Tel: 888 RAB-100C' • Fax 888 RAB-1232 • wlv,r.,.raoweb.corr- -f,'200E RAB LIGHUNG- LQS24y`"?77 Page I of 2 All Products > Sensors > Ceiling Occupancy Sensor > LOS2400/277 ICI ■I LOS2400/277 % Super Ceiling Sensor has 3 detectors for triple HID FLOODS coverage to catch small movements WALLPACKS LED testing and operation Indicator SENSORS —.,�, -- % Integral 30 amp power pack simplifies wiring QUARTZ FLOODS Controls 2400-2500 watts Incandescent or Fluc LANDSCAPE LIGHTING 120 volts VAPORPROOF ° % Maximum coverage - 3600 or hallway models VANDALPROOF I % Relay and sensor all In one unit reduces instaliz WORKLIGHTS Sensor detection pattern can be customized WEATHERPROOF Can be wired in parallel EXPLOSIONPROOF = Compatible with dimmers and electronic ballast POLES 120 and 277 volt models WHERE TO BUY CONTACT r UL Listing: Easy Installation: For indoor applications. Tuff Dome & Relay and sensor all In one reduces Installa Smart Box are UL Listed for wet Compatible with dimmers and electronic ba locations. testing and operation Indicator. r � Maximum Reliability: Maximum Versatility: Adjustable detector sensitivity for Adjustable time delay. Sensor detection pal superior detection, customized. No minimum load requirement wired in parallel, Coverage Area: Incandescent Watts Switched: 2000sf @ 9' 4800 watts Fluorescent Watts Switched: Ratings Amps Horsepower: 4800 watts 20 amps 1.5 horsepower Power Consumption: Time Delay: Negligible 6 to 15 minutes Manual Switch: Adjustments: Override key Time Sensitivity Detection: Patents: 3600 view Super Ceiling Sensor RAB sensor and fixture designs are protect( U.S. and International Intellectual Property Coior: White DIMENSIONS DETECTION PATTERN i�17n /Yv,tt .' rt�;�RrP.i: c nn-,!nr,-„ittM r�r Ya�l ,, ir,`• n.:'t,rt-Y �Ne Jd(O 77 RAP LICTP,-TING - LOS24C ''i i Page 2 of 2 © 1985-2006 RAB LIGHTING.ALL RIGHTS RESERVED. r — 0 0 4N, o O CD rm � s at .N B -3 gaA O o� � g o R:wg9� � � r CE 53'c . N m N a to to g d c M � a _ 5-0. w m m � 3 .. ... ... , 5 a 3 CD Ul o { � 3 51 m e o o x o r LA f 3 R" N C7 SL ° SL � � sum w $ � gms i r �o v � QO � a ° � � =zm0m0m 2 _� v mo -Ic p o A NQ ° O a � t5. m Zp �GO �� C 3 " -,PR Sim 1 � �9mz`-zo �� m9 Q + CL O° 9a W Q � „ J " p Q wm w $ w oc-!yO fl a. cff G�Tmm� m In y W 0 m t� o+ 0 0 °i A w ¢ N C) ° a a z a> z g ss L Will 3a 6 bR 5 A m in / _ 1 wHrrE ! 3 8gIca a r r r RED 4 v S BLACK OR ORANOE _ m r r C a a � r r C ) m m m r511, T> 0 1D � iF Q 9vU -R SL 0 70 � mtp " 1D ° waconz ca 31 � to gr SL ° � 3 m w � �mo4aen " v1°Ripi � � c a' �g �. "to 0r � n s i P a- 5- rJ S'N .' C 3 V1 �� '�A coN 3 N Mtn 0 3 �ul m� N c� r=- $ - N —aEr t0 c�n 'n 7• IA it Er g 7c• m 8 o �mi m, m I N �'7�c' m °0 tr tb �° 3 C �j 3° M g m S m r m Z f6 I c-r r i.Er St Yf 3 ir 0 CD Fr g Q fl m Q gg a ih ro m w _ L m u ul o w 5.° m Scn - � ��• � 3,9 01m••" $ � - � yy0QQ = 7rc05gm et.@mn.00 r- Se < gw �yN? m Vi m Pr m c ? t < SL $ � m I Ian o a fOo �° = o Q m Gf OL � Pa � w � a C v m�r� � � 3 m o r Oo 3� 2 1 T �.� m N 9 �� � Q LY or L CmO CD S gym ° �. � � 5'•$ �' � c mEo' $�� r -o �ofdm fin. � mgl V/ QWN o �(D �r5'� � N 0. _• Q G 7t' �m o a 3' CD 9 N � � c �� Qom � �^•a i Gonzalez Architects Architecture * Planning * Interiors MEMORANDUM Date: June 17, 2005 To: Greg Galmin, The Tower Group From: Jose A. Gonzalez,NCARB AIA Project: Freeman Justice Building Re: Request for Proposal—RFP#1 -Ventilation Cc: Larry Chalmers, Director of Construction & Planning, Monroe County Please provide pricing for the revisions pertaining to the ventilation as defined on the attached drawings, E3.02, E3.04 and M1.01. Four signed and sealed sets have been provided for your convenience. pE(DE0YE 32 East Bay Street,Savannah,Georgia 31401 * (912)201-9888,F )2d}�A4� 2005 2720 A North Roosevelt Blvd.,Key West,Florida 33040 * (305)294-3 8,F 1602 Alton Road,PMB 503,Miami Beach,Florida 33139 * (305)672-9 4; aT(� 1�6�ga,Z�r,� Inc I I I I r i ti I I a 2 WAKE fx8 �P -11 k— --_C2 ALUM L --- -- ,� CAP bx� ' po Frf 11x j a _ R X1m (—r —SEE k 12A Li ——4* 12A0 1— r—--� — —A - — U--4 1 - 1 . ----------- 12x12 DISGNARD LOUVER f IS GAUGE 81-It L_ Dr3CH,41 - - METAL --- _ /-LOUVER sr�Rout�===- - — _—-mil - - - _ - - 14X 14MO �� - -0_ —_ R I -_ -- R Xo END 1=ROf`1 Xle IfXI2 :LEX CG02*+E ION - FD. C �c9 - �24X24 INTAKE ----- - - C❑12x12 W,HIGH 320 Ag SIBLE a - - ----- ❑ AUG.10,2005 17:24 GONZALEZ A� --;ITECTS 305-294-8217 Page 2 i rAX 0 Td -'kE,r74te 0 gll Z(6� Gonzalez Architects Architecture * Planning, * Interiors MEMORANDUM Date: August 09, 2(H).5 To: Greg Galmin, he Tower Group From: Jose A. Gonzalez,NICARB AlA Project: freeman Justice Building Re: Request for Proposal-RFP#2-Deletion of Sallyport Rcstroum&2 Floor Drains Cc: Larry Chalmers, Director of Construction &Planning,Munroe County- Please provide pricing for the deletion of the sallyport restroom fixtures and associated plumbing --the mom will be utilized for storage. Also,provide pricing for the deletion of two(2) floor drains, one in the sallyport and one in Corridor 6018. Insure floor is sloped w drain out of the sallyport. rA 01E9WUb 10 2005 The Tower Group, Inc. 32 Fast Kay Street,Savannah,Georgia 31401 *(912)201-9888,Fax(912)201-0240 2720 A North Roosevelt Blvd.,Key West,Florida 33040 * (304)294-3748,Fax(304)294-8217 1602 Alton Road,PMH 503,Miami Beach,Florida 33139 * (3"672-9044,Fax(305)866-8324 IVUv UL UCk U I.Z)f p I fle I UWal tzirou J JUU-L»O-L UO/ P. Nook, The Tower Group, Inc. Cli�NGE ORDER REQUEST No. 00067 302 Fleming St. (Job-site Trailer) Phone: 305-296-2521 Key-West,FL 33040 Fax: 305-296-2587 TITRE: Elevator APE Electrical Requirement DATE: 10/31/2006 PROJECT:Freeman Justice Center(FJC) JOB: 0417 TO: Attn: Clark Briggs CONTRACT NO: 1 Monroe County Facilities Development 1100 Simonton Street Key West, FL 3 3 040 Phone: (305)295-4306 Fax: (305) 2954321 RE: SUB To: From: Number- 14240-01 DESCRIPTION OF PROPOSAL This Change Order Request(COR) addresses the additional electrical requirements for Anti-Poweroutage Entrapment Option(APE) specified by Gonzalez Architects for the elevators_ Gonzalez Architects electrical drawings and submittals do not refer to any additonal electrical requirements for this feature,and they are not included in the electrical scope of work. As part of the electrical service requirements in the Schindler submittal(copy attached), the APE requires one normally-open auxiliary contact and a dry contact(NC)of the GFI for each elevator car,to be provided by others. Without them the elevators will not comply with inspection requirements.. The value of this COR is based on the labor and material to provide the required additonal electrical work as per the attached breakdown. TTG proposes to provide the installation for an increase to the Contract Price of$3,970.86 and no change to the Contract Time. Monroe mint, Cyr rS�e:p� Ift., it}m.., O Item Description Stock## Quantity Units Unit Price Tax Rate Tax Amount Net Amount 10001 Material 1.000 LS S21.469.97 0.00% S0.00 S2,499.97 ✓ 10002 Labor 1.000 LS $633.42 0.00% $0.00 $633.42 Unit Cost: $3,123.39 Unit Tax: $0.00 Unit Total: $3,123.39 Subtotal: $3,123.39 Description Markup Percent Markup Amount Overhead 5.000% $156.17 Profit 5.000% $l 56.17/ Sales Tax $186.75✓ Labor Burden $348.38 Total Cost: $3,970.86 ✓ IVUV UG U43 u I.J/p 11117 I uWH1 Vluup JUO'L>'10'ZOOI PJ o i 10/28/04 Schindler Elevator Corporation Hydraulic Elevator lower Data Neg#: 568660-E-A-06 GO#: B7233 Unit(s) 06 Freeman Justice Center Capacity: 3500 lbs Product Code: 116 Jasckon Square Speed: 100 fpr.1 Sales Office: 6640 Key West , FL 33040 Travel: 29 ft. 0 in. Installing Office: 6640 LOCAL UTILITY SUPPLY 480 Volts 3 Phase CHARACTERISTICS 60 Hertz(cycles/second,' BUILDING SERVICE Voltage fluctuation of the building service pranded by the local utility shall be within+10916 to-10%of the specified Supply voltage, Maximum phase to phase fluctuat on shall be t3%. CONTRACTOR—SPECIFICAT;ONS,RECOMMENDATIONS,AND DATA POWER FEEDERS Electrical Contractor to supply feeders and ground of copper conductor and circuit protective devices from the building service to our controller,in compliance with local code requirements, along with Grcund Fault Protection as required per NEC 620-61. Maximum wire size used by electrical contractor in our controller shall be tlDAWG. Sprinkler System Note: Schindler Elevator does not provide arty elevator control-circuitry for ASME A17.1 Rule 102.2(c)(4). When required,Independent disconnection of electrical power prior to sprinkler a&vafion is by other contractors, and must be done in a manner that is acceptable to local jurisdictions. Additionally, one normally closed auxiliary contact of the heat detector is re ulred. PERMISSIBLE Not to exceed 3%under any condition in the feeders within the budding from the building service provided by the VOLTAGE DROP local utility to the motor connection in our controllers. MOTOR RATING 30 Horsepower Elevator Type Motor(80 starts/hour) This equipment is used for an intermittent elevator duty cycle. Requirements of the National Electric Code for a 30 and 60 minute motor may be used for slzing conductors provided the permissible tine drop in preceding paragraph Is not exceeded. On an intermittent basis 32.3 HP can be developed at full car capacity for 4.7 seconds. CURRENT VALUES Per Car Per Terminal (typical motor supplier data) Motor nameplate rated current at rated horsepower=41.0 amps,rms. Motor locked rotor current for solid state(soft start)starting=123.0 amps.rms. Siphase control load on maln supply is .65 amps.rms, SERVICE SWITCH Motor Cade Letter"B"for solid state(soft start)starting. For each car, we recommend a fused disconnect switch. The switch should be three pole 60.0 ampere with 60.0 ampere dual element fuses. For optional anti-entrapment/battery-lowering device(when specified)one normally �— open auxiliary contact per car is required. Additionally,a dry contact(N.C.)of the GFI would be needed(both are rovided b others). Anti-Powerout a Ent ment o 'on(A-P.E.)has been selected for this car. PANELBOARD The Electrical Contractor shall be responsible for any inverse time circuit breakers used in place of or between the BREAKER service switch and the buddng serlice. There should be a motor control type suitable for 80 startsftur service and capable of withstanding locked rotor current and any asymmetric SWIctvng transients. Refer to local Sales Office, AUXILIARY FEEDER One Supply per Car Controller for Car Lights and Fan per NEC 620-22. Also, a dedicated,labeled, 111 15A circuit and conduit for the APE wring in compliance with local code requirements.Also,a loci ie disconnect is required per NEC 620-53. 120 Volts 1 Phase 60 Hertz 15 Amps CONVENIENCE Light, light switch and convenience outlet(s) in each elevator pit and/or machine room are to be provided by the FEATURES General Contractor. Each 125-volt,single-phase,15-and 20-ampere receptacle must each be of the ground-fault circuit-interrupter(GFI) type per NEC 620.85. Note: ANSI A17.1-2000 now requires the lighting in the machine room to be a minimum of 200 Lux 19 ftc. HEATING AND The machine room temperature must be controlled in order to maintain ambient room temperatures of 55 to 90 COOLING degrees Fahrenheit. Heating or cooling may be required to maintain the minimum or 111118AMILm temperatures. Acceptable humidity level in the machine room shall be maintained at 95% or less non-condensing The heat emission of the pump unit is 7,594 BTU,'Hr with normal load cycle conditions. UTILIZATION Additional branch circuits, other than the lighting feed, shall be provided to supply other equipment such as EOUIPMENT FEEDERS displays,intercorrs,TVs, etc.,as required per NEC 620.25 and 620.55. SMOKE DETECTOR The Building Smoke Detector system, required .`or firefighters service At 7.1-2000 2,27.3.2(ASME Rule 211.3bi, NOTES shall provide a normally closed contact ihal opens on activation. 1 i By Date. Time Visit Our website at www.us.sChindier.com 2004.5 UL. uv VI.U/1.1 IIIH IVN/tii v1VuF1 p.'i � OOtaD GOO O 00000 b � M � O to tD O 1� O q CD 0 0 0 0 0 � � mV o o co o O cV O M O O C . M ad Qj cp ap tta0 wLm �4MFl ci q! � CD J a 0 zwwmwUoUa2000 J. M x 4 90 �a. 0 O 1t100 M gig 00000o a ml� ro CZ� C:s 000 ll- Q ccri ovcuio o O z Q O O e- O A O N ri W It O co aCeV et ttMOMNr O 0) CO W N O r r N w N O M O O O Q J F" 609 � � eOA � � fR1R lOR nj U_ w m � J F- a U � W O J 0 W H Z W W U lw U U lululs U U W W :3 a Q Q W I"' OCDOO 1A00LA O N M 1- 1A N N CDN O 00 a- W CD Q D 10 1-. 1.- 0 w of Vl*9-U} %- a- bArN! rr M10 O W � tnF- y�. 1000 z Z Wz �D � Z 0) F- uj z w VnUaZoN ) m OW OOUr v g — - :* 1so W M i a w ~ W w 2 Q W � a � � W aF- U = M W = M M O Z W W � W W W LL W W WmIUJ LL La> [DONCDNON N � MNr avow uz ut ui:wp i ne lower group 305-)n5-2587 p,5 -- . �.. ...: �.. �.v►v YAl1L 1 ur L GE GE SUPPLY- POMPANO BEACH Supply 2009 N.W. 33RD ST. 0 POMPANO BEACH FL 33064 Order Confirmation Thank yo■for your order. The sutus of your ibms appoers below each c3rslo9 number. Pkusa kelp a copy if this docunow lot your records, Pleass note This e-mail message was saw from a noduation-oaiy address that mannat accept incoming a-mail.Do not reply to ibis rnessa(te. "vat have any questions regordinq this order,piwse contact your sates representative at the number below.You may check Order status at any OrderlF. 390-041573 Crm POt 0417 tans by lapping an to www.gesupply.com and eiie king on`My Ae co ueT". From CHRIS DOANE To: THE TOWER GROUP INC Phone#: 954-977-2613 FL/FREEMAN JUSTICE CENTER 302 FLEMING ST E-Afti(: CHRIS.DOANEOGE.COM KEY WEST FL 33040 Aulostion: THE TOWER GROUP INC Deb: 10/31/2006 11tE n0 mtscown OLMMITr1 aarll MOOT am VMNOEO TOTAL 01 783164AO535 THAUX64DI 30-200A AUX CONTACT KIT 2 88.00 E 176.00 ITEM IN STOCK - REQUESTED DATE IS 11/91/2006 02 78316416101 7RK36AI NEMA16-3R100A FUSE KIT 6 15.60 E 90.00 ITEM IN STOCK - REQUESTED DATE IS 11/91/2006 03 783164AO535 THAUX64DI 30-209A AUX CONTACT KIT 4 88.00 E 352.00 ITEM IN STOCK - REQUESTED DATE IS 11/91/2006 TOTAL 618.00 TOTAL DOES NOT INCLUDE TAX , SPECIAL HANDLING OR MISCELLANEOUS CHARGES ORDER IS TAXABLE CUSTOMER NOTES: ATTN:JOSE CLAUSEL lroits: GE Supply's Conditions of Safe`(aTlechod,proviouely delivered,of as posted on gesuppiy.com)will appfy.Shipping dales are manufacturers estimalas and not gtraranpesd.A manufacturer's po ww"MV rney apply.BUT GE SUPPLY MAKES N0 WARRANTY,EXPRESS ON tMPL1ED,WRITTEN OR ORAL(INCLU DLNG MERCHANTABILITY AND FITNESS FORA PARTICULAR nufact5E1. You are resnsible to verity GE Supplys sterprelation of ymr plans and apecs,and ecceptabiiryat items quoted as substitutes.GE Supply has no liability at ail above the purchase erdar valu►in any claim,or for anylabor,installation or otlwr associated costs,or for any consegaertial,liquidated,punilive a incidental damages. Thank you for yoo►odor. vu I i.,+,Dd I f1fd I UVV(dl V I UUP 13UD_ZZ10_/_00 f P. I he Tower Group, Inc. CikANGE ORDER REQUEST No. 0069 302 Fleming St.(Job-site Trailer) Phone: 305-296-2521 Key West,FL 33040 Fax: 305-296-2587 t TITLE: Security Rev HM Frame Installation DATE: 11/6/2006 1 L i".4 PROJECT:Freeman Justice Center(FJC) JOB: 0417 TO: Attn: Clark Briggs CONTRACT IN .14 Monroe County Facilities Development 1100 Simonton Street Key West,FL 33040 Phone: (305)295-4306 Fax: (305)295-4321 RE:CO To: TTG From: MCCM Number: 00012 DESCRIPTION OF PROPOSAL "This Change Order Request(COR)addresses the installation of replacement hollow-metal door frames. Gonzalez Architect's Security Revision,which was finalized by CSA,required the original hollow metal frames to be replaced with frames which were manufactured to receive security hardware. The replacement hollow metal frames were provide by executed Change Order 12 on May 3,2006. This COR is based on the tabor to prepare the inside of the frames for installation(corrosion protection)per specifications,to install the frames in the existing masonry and concrete wall openings,to fill the frames solid with grout as per specifications,and to repair and complete the finish of the existing walls at the door heads,jambs and sills where required. The door frames affected by this COR are:G 101,G 101 A,G 102,G121,GI 22,G 123,GI 24,G 124A,G 125,Gt 26,G 127,G1 29, G 133,G I 34, 1101, 1118,1175, 12D6,2101,2114,2152,and 2179 Please issue a Change Order to the Contract for$6,477.10 and no Time Extension for this extra work- "OUTING 00 Item Description Stock# Quantity Units Unit Price Tax Rate Tax Amount Net Amount 00001 Labor:!men x 5 hours Mrarne x 220.000 man hours $16.80 DM% S0.00 $3.696.00 22 fiwTlcs 00002 Material&Equipment:grout. 22.000 each S35.00 0.00% S0.00 S770.00 bitumen,mortar,chipping hammer 8e drift Unit Cost: $4,466-00 Unit Tax: $0.00 Unit Total: S4,466.00 Subtotal: $4,466.00 Description Markup Percent Markup Amount Overhead 5.000% $223.30 ✓ Profit 5.000% $223.30 VZ Sales Tax Materials& Equir $52.50 45%Labor Burden $1,512.00 qC, Total Cost: $6,477.10 MEMORANDUM TO: Board of County Commissioners From: Thomas J. Willi County Administrator Date: January 2, 2007 RE: Change Orders Attached is a proposed change order for The Tower Group, for the Freeman Justice Center. (Change Order #26 in the amount of $63,645.33 is for plumbing, electrical requirements, installation of carbon monoxide monitoring, controlled lighting for parking garage and door frames that accommodate security hardware upgrades.) According to the ordinance adopted by the Board of County Commissioners, proposed change orders are to be presented to members of the Board of County Commissioners prior to approval, assuming they are within the Administrator's prescribed limits. Change orders not within the Administrator's authority are placed on the BOCC agenda. The Administrator intends to approve this change order on Thursday , January 4, 2007. Thomas illi County Adm nistrator TJW:adc Page 1 of 1 € E ampo-Abra From: Campo-Abra Sent: Wednesday,January 03,2007 8:41 AM To: County Commissioners and Aides Cc: Haskins-Anna Subject: Change Order Attachments: 00003354 354.tif Please review the attached Tower Group Change Order #26 for the Freeman Justice Center. Abra Campo Sr.Administrative Assistant Office of County Administrator 1100 Simonton St. Suite 205 Key West, FL 33040 (305)292-4445 1/3/2007