Loading...
Item C23 C.23' i�` CountCounty ��Monroe. ,y, ? "tr, BOARD OF COUNTY COMMISSIONERS y M T� \�1a� Mayor Michelle Coldiron,District 2 �1 1 nff `_ll Mayor Pro Tem David Rice,District 4 -Ile Florida.Keys Craig Cates,District 1 Eddie Martinez,District 3 w Mike Forster,District 5 County Commission Meeting January 20, 2021 Agenda Item Number: C.23 Agenda Item Summary #7722 BULK ITEM: Yes DEPARTMENT: Project Management TIME APPROXIMATE: STAFF CONTACT: Breanne Erickson (305) 292-4427 N/A AGENDA ITEM WORDING: Report of monthly change orders for the month of December 2020, reviewed by the County Administrator/Assistant County Administrator. ITEM BACKGROUND: There were four (4) change orders considered and approved by the County Administrator/Assistant Administrator for the period beginning 12/01/2020 and ending 12/31/2020 for a total of$52,725.93. There were no change order requests denied. PREVIOUS RELEVANT BOCC ACTION: On September 9, 1998, Ordinance No 027-1998 was adopted in order to provide that the County Administrator may approve separate, non-cumulative change orders for construction projects and professional service contracts in amounts not to exceed $50,000 (as amended per Ordinance No. 024-2015), or 5% of the original contract price, whichever is greater. The BOCC requested a monthly report of all change orders considered by the County Administrator. CONTRACT/AGREEMENT CHANGES: N/A STAFF RECOMMENDATION: N/A DOCUMENTATION: Change Order Rpt_December 2020 FINANCIAL IMPACT: Effective Date: N/A Expiration Date: Total Dollar Value of Contract: N/A Total Cost to County: Packet Pg.808 C.23' Current Year Portion: Budgeted: Source of Funds: CPI: Indirect Costs: Estimated Ongoing Costs Not Included in above dollar amounts: Revenue Producing: If yes, amount: Grant: County Match: Insurance Required: n/a Additional Details: No N/A REVIEWED BY: Cary Knight Completed 01/04/2021 11:32 AM Joseph DiNovo Completed 01/04/2021 4:33 PM Purchasing Completed 01/04/2021 4:40 PM Maria Slavik Completed 01/04/2021 9:11 PM Budget and Finance Completed 01/05/2021 10:27 AM Liz Yongue Completed 01/05/2021 10:44 AM Board of County Commissioners Pending 01/20/2021 9:00 AM Packet Pg.809 R ( aagwa3 - � jape q llglu® ) a gw93 -4 japi q :4u9ua 3 44 CD c^i 5 - c a Es c is a c q- E q0 cam° E � � 0 � � � > G) t) ' � oEE ° � u n rod a co o ¢ Yo c mQ+� a) o � o o c m o s c i< T o U V V r0 "0 N > N Ln O .0 N > N W O Q O Q C V N V 0 W 0 —u 0 W Ln a) 0 fa 0 N Ln a..i N a..i fa N fa U ua) c � � � v U orn 3 U 0u O> 6 L 0 C 2 C 0 L L d 2 � O � a m N V 'u N u a0.� `n Q 3 0 7 u a� 3 o E rc: +� o O Ln N mO mT.- C 0 N N rn a u O L 0 rn a-i " ao n � o c 3a� EE � 0a� 01Cw N O-V 0)2 f ��+' N V a) +' C 01._ In a.:i C C C f0 N L a V u O e V f0 0 V 0 0 — d a..i V — O (n 0 -00 d In Fn N U U O C V O v _00 W O N 0 N D LL W * 0 W � * 0 w * O Q: LL W W o C) 0 W W o L W W Cr:,) Q 0 LL HD n o Q Q: � 0 � 0. � 0 ; Q0. w c v� � a D a ri) N a Z (np p � W DOS DO � a 0 U Z U U M V ~ M F _0 o Q T Ln V HN aim V v a)o — N W � ,� Zoe � Z o az � a„ o CZ I � ) ND a) 00 O` ja� 2 N �..� p o v 0 o '�' � 3 a� LA N o c n V a \ � om Yu a) Z V � c =,— o � a 4x b2mt Q p 0 6 0 0 0 W V W V n O WN 0 cnani c: 'n 0LU �_ Q: LU � w0 5 0 q- W D 0 n Q c 0 o oC 0 0 0 -0 cam, E Q 3 o 7 V H V m of (=j o z �..� a .__ 3 o` W W W M N W C O = a M c) � � N �? az o Ln O 00 � ri 0 0 a` 0C c m Q a o Qoo o a GLU p C 0 p N = H W � Q: W U W u zo = 3 " 0 V 0 J = a cn OC U) OC o o p U o 0 0 T U U j QV 'n c o H o 413 c OC u E ~ Z �i 0 Z o v Z EU U a V a U m c U c i o0 � z U U a W U i O W O U W a)h J C a=i hU C W C 0 (% W^� N C W^� �_ V QI 0 0 - N I� Y a) A� ca 0 0 U WU- 0 0 O 0 0 + O0 0 C 0 O C � U O Q 0 0 0 2: U a MONROE CouNTYANGINEERING/ PROJECT MANAGEMENT CONTRACT CHANGE ORDER PROJECT TITLE: CHANGE ORDER NO: #16 Monroe County Library and Adult Education INITIATION DATE: 11113/2020 Center, Marathon Branch CONTRACT DATE:031211cv 2019 TO CONTRACTOR: Pedro-Falcon Contractors, Inc. 31160 Avenue C E Big Pine Key, FL 33043 The Contract is changed as follows: 0 The original(Contract Sum)(Guaranteed Maximum Price) ....... ........ ........$7,016,385.00 Net change by previously authorized Change Orders......... ............................. .......... $ 750,660.01 The(fontract Sum)(Guaranteed Maximum Price)prior to this Change order was .............$7,767,045.01 The(Contract Sum)(Guaranteed Maximum Price)will be flng[Ngo(decreased)(unchanged)by this Change Order.............$ 11,640.89 0 The new(Contract Sum)(Guaranteed Maximum Price)including this Change Order is ......$ 7,77 .90 a) The Contract Time will be(increased)(decreased)(unchanged)by..............i.................. 0 Days The date of Substantial Completion as of the date of this Change Order is........................ 3/06/2021 Detailed description of change order and justification: During construction, a couple discrepancies andlor omissions were identified with respect to plumbing. It was brought to the Architect's attention that a regular shower head, in lieu of an -co pliant shower 0 system, was specified in the plans. It was determined that an -co pliant shower system would be 2 required Additionally, while reviewing cabinetry for the planned breakroom, the prime contractor identified a proposed sink where no plumbing was identified in the plumbing plan set.As such,plumbing and electrical plan updates were provided to add the required plumbing and hot water capabilities to this area. This change order incorporates all labor, equipment, and materials to complete this additional work. No additional contract time is required for this change. E Change order is 0.17 of ork6gql,contract price. Not valid.unti,l,signed bV Owner,Architect-fif-appi icableianh Qontfi-4�, ARCHITECT: 0 Syn SA Rome ye LLC Date a) CONTRACTOR: 49 Pedro-Falcon Contractors, Inc. Datd' Digitally signed by Cary Knight I T J T T E Cary Knight Date:2020.11.23 11:05:40-05'00' DRECOR PROEC MANAGEMEN Cary Knight, irector Date < Projo cn-Kevin G.Wilson,P.E.,o-Monroe County,FL Florida Keys,ou,email-wilson- kevin@monroecounty-fl.gov,c-US COUNTY/ASSISTANT ADMINISTRATOR: 2020.11.25 11:51:23-05'00' Raman Gastesi Date Kevin Wilson Christine Hurley Packet Pg. 811 C.23.a Change Order Attachment per Ordinance No. 004-1999 Change Order was not included in the original contract specifications. cv If Yes,explanation: This additional plumbing is required but was not included in the contract plan set cV t bid t►me. Change Order was included in the original specifications. Yes No If Yes, explanation of increase in price: 0 m e Change Order exceeds$50,000 or % of contract price(whichever is greater). Yes No m If Yes,explanation as to why it is not subject fora calling for bids: e Project architect approves the change order. Yes El No — If n , explanation of why: o cv e Change Order is correcting r or omission in design document. Yes NNo Elc� Should a claim under the applicable professional liability policy be made? Yes Z No Explain: Yes, this change order is a result of plan discrepancies or omissions. All errors and omissions will be reviewed at the end of the project to determineif a claim should be made. i m m Packet Pg.812 C.23.a PEDRO FALCON CONTRACTORS, INC. 31160 Avenue C,Big Rine Key,FL 33043-4516 872-2219 EC 1 /CGC 1507617 Request for Change Order NovemberCD io N Project:Marathon r E Description: Sink at BreakroOm 3-215r Head&2Rd Floor Line for Refrigerator .....................................—............ ......... ........, ,......... ..........................................».:............ m m F&I Plumbing Sink(see attached)...........................................,............................$6,793-00 F&I Plumbing Shower Head(see attached) ...................................................... , 669.64 ........ ............................................ .............................. Subtotal ..................................................................... , . CD PFC—Repairs to . -. N ng Work CD Remove&Replace Gypsum Materials ....................................................................$16o.00 1 .................::.................. ............... ................................................................................................ �i . . ......,............................................................ Sales Tax on Materials ............................................................................................. 1 . 00 Subtotal PFC .................................................................a........ . a) ElectricPFEC .................................................................... 1, 639-00 ......... ......... ....-... ......... ....................................................... 1. ...................................................................................................... $81.95 Subtotal PFEC d,,,ectrical......................A......................q.......oY..............• , 802.90 Industrial-Commetrial-InsUtudowl-Reshl4nUal- Packet Pg.813 C.23.a &P +g iei% TotalCost..............er�sreero���e�s.�.d�.e®��rm......... Total ygp ereim+aewvsarya®� e .14 o u estfor Change Ospe xt , AnoBygler Project Manager c a) 0 CD CD w i a) CD Packet Pg.814 C.23.a BACKCHARGE -5 -1 DAB MECHANICAL r LITTLE ILL DO YA" 1717 SW IST WAY,SUITE 27 DEERFIELD BEACH,FLORIDA1 N 'P^ FIFT;5AL.SI aMITTDTO: PHONE:. V rdAT.E;.. t PEDRO FALCON COTRATORS 35- 72- 21 14/30/ 00 `E STREET 1013 NAME, 31160 AVE C MARATHON LIBRARY&ADULT E � UTY,STATE and ZIP CODE J0?LOCATION: BIG PINE KEY,FL 33043 SHOWER DESIGNCHANGE PER ARCHITECT ARt H11 ECT: '.JOB PHONE: C� we here by submit ipeckficanom and astimatm roe: � INCLUSIONS: 1, 1 HN300 SHOWER SYSTEM $ 1, 1.03 2, 1 SHOWER DIVERTER 249.86 1/2" CXM PP ADAPTER1.40 4, 2 1/21, WING ELL 12.00 S. 6 1/2" 909 21.90 6. 4 1/2" 452 12.00 0 7, 4 1/2" FULLSTRAP $ 4.00 8. 4' 1/2" L COPPER PIPE 12.00 N 1, 1 .1 CREDIT: 1. ZURN Z7000-S7 S $ (39.50) 2. 1 ZURN Z71 0-SS-H VALVE $ (93.00) (1 . ) LABOR JOURNEYMAN 7 2 HOUR $ 150.00 SALES TAX REIMBURSEMENT . a) OVERHEAD 10% 1 . 2 TOTAL: -- 1,669.64c, ONE THOUSAND SIX HUNDRED SIXTY-NINE 64/100 Dollars $1,669.64 m Payment to be made as follows: 0 Signature: Date: y signing my name, I certify that I have read the above proposal.My signature also certifies my understanding and agreement with the above terms. Packet Pg.815 C.23.a DATE RECAPULATION PESRO FALCON SHEET ELECT.COWRS.INC FOR N,q ABM PAI Staki ETPON rdxSx Laf€oLl'iay.e2 (ti;49t!Wn.L.a:I,r-WypS I.,Apaag.w'�,nf ff46: LIGHTRIG }. 0,00 4.no% 0.00% B,.-h P® S 09 12, 11.00 49.74% as,61 a ¢eh Gar 3 lii.Fs0 619 S416% 3439% GENERATOR 'S 0,00 0.00% 0.001A Mr.Ab— 'S. ., 0 0.0% 0.00% SaetSrltp SYate 3 0.00 0,0% 0.00% Cm ■t. $ 0 0.00% 0.00•A N CCITY '}, 0 *,00 G 0.06% Lightning Fro m S • 0.15k 0100% 0.00% CD P.M.Add - 1100 0.00®',� BAD% L.Cnth®dlc P'rakesttOm 5 ttiM3 0.00°4 0.00% "Aut. S - 0CIS! €tfwllk 0.0dW to � TOTAL MATERIAL&N1ANa94URU ffi 194...2 18a9 NMADIA 30.04"11. C MISCELLANEOUS dNl,k l-Y.R0.AL.k v_nyj,Cr C SUBTOTAL MA;TERI LL S 62 � TAXON TE (7-in%) S 40.05 TOTAL MATERIAL COST S 585.46 FOREMAN HOURS 5 RATE _?i iS.07 2.7415 3 123.46 JOURNEYMAN HOURS05 RATE r+.;tai M29 3 64"5 TRAVEL i NON PRODUCTIVE I OVERT - T ' IN RfCr LABOR-TOTAL COST 5 763,61 � PAVROLL TAXES -RATE � 39'Bi•,� � g, 290.17 t<W1,14e1�9kY rQ ew S -- , 5„ I V N€.tC;.cC!9 uA h•.5';n,'t•Ey, s. . `TELEPHONE FREIGHT EXPRESS AND CARTAGE S§B,Ld 4!T fXtll9P,N$ 3 SANITARY $ W S ENPENS)SILLODGINGMEALS ;�. PROJECr TRAVEL(p Op THIN RATE) TOOLS 04 OF ) -- — -g TOTALJOB t",NPE'I..:F - _ 3 290.17 TOTAL PROBE C TERffi' RIJOB .) 5 t,699.29 OVERHEAD% s 2 k�u3A xt N k WW45 ALAR.69 B 1 S R IO MENG PROTECTION 1 t L. 8 Sh�4�i R3Ir^JWS;ry3Y9 wxt J, t svrmraxt-sokw I C SUB-CONTRACTOR TOTAS. s .. Tea R1W°arl. s SUB-CONTRACTOR G D TOTAL 3 - ¢' Rub Cmmaractm m@ k.p ow% 000 O00 TOTAL NET COST s 1,6.39,P.d FRONT% .£ � SUBTOTAL S 1,639.14 BON® s a) SELL NC PRICE tJ S,Q.FOOTAGE - ,.FT. St PI'd.'.G3ST" m!TlVtiIW 5 ,.Bfi, T N¢v9 ufe now d li,�rualtrvm laic. Bbr7.t®®v 0 ., w ._...,.--..... ,..,.... .,.,-_�.w..:....«-- WW SVWrR h4rna. I`!-6 "Inrm D! AIaU I%6AYY fw%pSstlYaaTM.k�dlt m..,.•. ...... _ I meaW tlr ei e'W 14's A 4.a:r.g.It.—.e W5,k... A€i'. ftu�e'ri: •-•..�•. ___-_—... Tm-a iggo l.W,li.t" IN linker, _ Ale±j r€3 fr'aae W Cte M. Packet Pg.816 C.23.a REQUEST FOR CHANGE -S9-2 MECHANICALDAB I LITTLE ILL 00 Y " 1717 SW 1ST WAY,SUITE 27 DEERFIELD BEACH,FLORIDA 33441 9S"B&-2690 FAX 9 -� 'PROPOSAL SUBMITTED M-. PHONE: DATE: N CD PEDRO FALCON CONTRACTORS 305- 7 -2216 11/9/2020 STREET: IOB NAME: ) 3110 AVE C MARATHON LIBRARY&ADULT E CITY,STATE and ZIP CODE JOB LOCATION: KITCHEN SINK ON 2ND FLOOR BIG PINE KEY,FL 33043 ARCHITECT: IJOB PHONE: We here by submit speciflcations and estimates for: INCLUSIONS: 1. 80, 2" PVC SCH 40 PIPE 165. 4 of 2. 10' 1/2" TYPE L COPPER PIPE 426.00 3, 6 ' 1/2" FIBERGLASS INSULATION 216.00 4. 1 301 x2" PVC WYE 23. 5 5. 1 3"x2" PVC SAN TEE 22.13 & 1 2"x1-1/2" PVC SAN TEE 17.45 0 7. 2 2" PVC TEST TEE WITH PLUG 31.1 & 6 2" PVC 1/8 BEND 24.78 9. 6 2" PVC ST 1/ 26. BEND C D 10. 4 2" PVC SCH 40 COUPLING 14.80 11. 3 2" PVC SWEEP 18.27 .0 12. 6 2" PVC 1/4 BEND 30.9 13. 1 1-1/2" PVC 1/4 BEND $ 2.79 14, 1 1-1/2" PVC TEST CAP 1.15 15. 1 PVC GLUE 22. 9 1 . 1 PVC CLEANER 31. 1 ' 17. 1 METAL SAWALL BLADE 15. 1 . 2 1/2" PP BALL VALVE 56.0 of 19. 1 1-1/2"xl/2" PP TEE COPPER 37.80 20. 1 1-1/2"x1/2" PP TEE COPPER 24.90 CJ 1,210.52 CONTUNUETO NEXT PAGE Dollars Payment to be made as follows: Authorized Signature! Date: Packet Pg.817 C.23.a REQUEST FOR CHANGE ORDER DAB MECHANICAL INC. "A LITTLE DAB WILL DO YA" 1717 SW 1S7 WAY,SUITE 27 DEERFIELD BEACH,FLORIDA 33441 2 FAX PROPOSAL.SUBMITTED T0° PHONE;.._.. DATES CV CD PEDRO FALCON CONTRACTORS 305-872-2216 11/9/2020 STREET: JOB NAME: � 31160 AVEC MARATHON LIBRARY&ADULT ED CITY,STATE and ZIP CODE JOB LOCATION: KITCHEN SINK ON 2ND FLOOR BIG PINE KEY,FL 3303 ARC 141ITCT, if]F1 PHONE: e.fterF bVsunmitsgeel#'ieatlons and estimates f= INCLUSIONS: 21. 20 1/2" PP 909 COPPER 79.0 m 22. 4 1/21' PP ST 909 COPPER 31.92 23. 10 1/2" PP 459 COPPER 2.30 24.. 6 1/2" PP ST 459 COPPER 2 .2 25.. 10 1/2" PP COUPLING COPPER 3 .0 26, 4 1/2" PP TEE COPPER 26. 27, 2 1/2" PP MALE ADAPTER $ 16.70 2& 1 REF BOX 73.49 CD cv 29, 3 1/2" HAMMERARRESTOR42.00 CD cv 30.. 160' / " PLATED ALL THREAD ROD 166.00 31. 50 3/811 NUTS $ 4.50 E 32. 50 3/ 10 WASHER $ 3.50 33 50 3/811 SAMMY ANCHOR 131.00 . 20 2" GALVANZIED HANGER 6. 0 35. 34 1/211 COPPER HANGER 91.9 3 . 10 GALVANIZED CADDY BRACKETS 37.00 37. 1 2" GALVANZIED RISER C 10.25 0 38. 3 2" GALVANIZED TWO HOLE STRAP 14.00 m 3 .. 20 1/2" FULL STRAP 2 .0 40, 2 1/21' P HARD CAP $ 12.00 93 .2 CONTUINUE TO NEU PAGE Dollars _ Payment to be made as follows: Authorized Signature: Date: Packet Pg.818 C.23.a REQUEST FOR CHANGE ORDER - 1-5 9-2 MECHANICALDAB INC. "A LITTLE DAB ILL DO YA" 1717 SW IST WAY,SUITE 27 DEERFIELD BEACH,FLORIDA 33441 PROPOSAL D5AL 5U8MITTED TO: PH&7NE; DATE: PEDRO FALCON CONTRACTORS — 72-221 11/ /202 CD CD — — — cV 5rRE„'ET' 10A NAME: 31160 AVE C MARATHON LIBRARY&ADULT E .0 07Y,STATE and ZIP CODE JOR LOCATION: W U KITCHEN SINK FLOOR BIG PINE KEY, FL 33043 ARCHITECTG — It�6PHONE:...... O _-We here kmy nAirrmat sppc%llcatians and estimates For: INCLUSIONS: 41. 1 TUBE FIRE CAULK 1. 1 m 42. 1 FIRE WOOL 2 .1 , 2 310 HOLE CORE DRILL450.00 44. 1 ELKAY SINGLE BOWL $ 612.00 _ 45. 1 TWO HANDLE KITCHEN FAUCET $ 199.00 46. 1 CHROME BASKET STRAINER 7 . 47, 2 1/2"X /8" CHROME ANGLE STOP 15.50 `-' 4 . 2 / " SS FLEX SUPPLY T 18.80 N CD 49, 1 1-1/2" 17G -TRAP CHROME $ 56.79N 50. 1 1-1/2" 17GA TAILPIECE CHROME 2 . .0 51, 1 CLEANOUT COVER 15.3 52. 1 TANKLESS WATER HEATER 350.00 , 1 . 2 LABOR: 1, J 75. 0 X 16 HOURS 1,200.00 2, APPRENTICE $45.00 X 16 HOURS 70.0 :m m SALES TAX REIMBURSEMENT 235.63 OVERHEAD 1 % 617.55 ,793. 0 SIX THOUSAND HUNDRED NINETY-THREE / Dollars Payment to be made as follows: Authorized Signature; Date: Packet Pg.819 MONROE COUNTYANGINEERING/ PROJECT MANAGEMENT CoNTRAcr CHANGE ORDER PROJECT TITLE: Cudjoe it Station No. I I INITIATION DATE: 1211412020 CHANGE ORDER NO:06 TO ® (West CPRs as noted) West Construction,Inc. CONTRACT DATE:0811512018 E The Contract is changed as follows: .............. The original(Contract Sum)(Guaranteed Maximum Price)... ........ $3,884,185.00 Net change by previously authorized Change Orders............... .............................. $37,745.93 0 The Contract Sum) (Guaranteed Maximum Price)prior to this Change order was.......... $3,921,930.93 The fContract Su )(Guaranteed Maximum Price)will be(increased)(decreased) 6,3 (unchanged)by this Change Order.................. $11 73.46 The new (Gontract Sum)_(Guaranteed Maximum Price)including this Change Order is..... $4,038,304.39 0 a) The Contract Time will be(increased)(decreased)(unchanged by......................... 0 days The date of Substantial Completion as of the date of this Change Order is.... ............ 12J31/2019 The fbllb ins issues reggiLre this chaage order 1) This Charm e ddresses myltiale Chan e,Pro a/Requests 6QPRsj glybrniftedb est 0 _ q___pw yW 2 Construction, the Contractor. See all backyn and attachments for details regarding each CD CPR. C44 CD C44 2) Asper the West change proQosal reagest additional time to the contract will be detenpined at a Latjr at E This change order Is 3.00%of the original contract price. Not valid until signed Owner Architect licableh and ContractorV e jlf,app ARCHITECT: /Zo z a 0 CPH, Inc. Date CONTRACTOR: >z" West Cons6u Date Digitally signed by Cary Knight r y�K t g h t Date:2020.12.29 10:19:26-05'00' DIRECTOR PROJECT MANAGEMENT E Cary Knight te cu Kevin G.W11son,P.E.,o—Monroe County,FL(the For —wilson-kevin@m de Keys,ou,email onroecounty fl gov,-US COUNTY/ASSISTANT ADMINISTRATOR: In-I I In mqon' Roman Gastesi to Kevin Wilson Christine Hurley PROJECT TITLE: Cudjoe Fire Station No. 11 Packet Pg. 820 C.23.a INITIATION DATE: 12/07/2020 CHANGE ORDER NO: 06 TO CONTRACTOR: West Construction, Inc. CONTRACT DATE: 08/15/2018 This Change Order No. 06 includes the following Change Proposal Requests (CPRs) from West Construction: West CPR# Reason for Change Proposal Request(CPR) CPR Amount* N cv CPR#5 Increased wall thickness of beam $ 2,568.95 CPR#7 Tower Dimensions Discrepancy $ 2,780.25 CPR#8 IT System Furnish & Install $ 13,822.90 0 CPR#10 Added Column to Mezzanine $ 1,529.69 m CPR#11 Decking for Canopies over Apparatus Bay Doors $ 33,266.83 m CPR#12 Credit for Color Concrete $ (1,466.29) CPR#15 Lighting Fixture Color Change $ 2,160.25 CPR#16 Relocate Hose Reels-Combine to Air+ Power $ 10,244.69 CPR#17 De-Con Shower Fixture Change $ 1,203.48 cv CPR#18 Steel Plates to Stabilize Stairwell Block Wall $ 7,903.69 CPR#19 Structural Fix for Generator Deck $ 19,826.82 CPR#20 Change door function with additional hardware $ 6,846.65 ¢� CPR#21 Revision to Irrigation System $ 9,357.47 CPR#22 Add Circuit for 6th Overhead Door Motor $ 1,334.37 m CPR#23 Relocate the termination of the new IT Conduits $ 1,918.76 CPR#24 Relocate Domestic Water Booster Pump Power $ 573.24 CPR#25 Tile Corner in Lieu of Bullnose Tile $ 278.03 CPR#26 Upgrade Fuel Dispensing Hose to 100ft. $ 2,223.68 TOTAL $ 116,373.46 Packet Pg.821 C.23.a Each of the above CPRs, is presented with the following documentation: • Summary of the issues requiring the CPR. • Change Order Attachment per Ordinance No. 004-1999 (for each CPR) • The Contractor provided CPR and backup for each amount requested. CPR#5 Increased wall thickness of beam $ 2,568.95 The following issues require this change order: cv 1) Per the comments on the "Approved as noted"shop drawing submittal for structural steel, the wall thickness of the HSS 10x8x%inch beam was increased, by the reviewer, to %inch wall thickness. This increase in thickness doubles the weight and cost for these steel beams. 2) As per the West change proposal request, additional time to the contract will be determined at a , later date. 0 CPR#7 Tower Dimensions Discrepancy $ 2,780.25 The following issues require this change order: m 1) Due to a discrepancy between the Architectural and Structural plans, the tower projection on the northeast corner, was formed and lathed to the wrong dimension. After confirming the c� discrepancy and correct dimensions with the Architect, the reinforcing steel was removed from both tower slab proiections and the form work reworked to the dimension shown on the Architectural plan—an increase of two (2) feet. The reinforcing bars were replaced with correct c size bars to accommodate the longer cantilever of the slab proiections. As per the West change proposal request, additional contract time will be determined at a later date. cv 2) As per the West change proposal request, additional time to the contract will be determined at a later date. i CPR#8 IT System Furnish &Install $ 13,822.90 The following issues require this change order: 1. This is a County requested proposal to provide the conduit, cabling and jacks (ports) to support the installation of networking, telephone and cable television (CA TV) required by the owner, Fire Rescue, and the County IT Department. 2. Contractor shall verify field locations of data & telephone ports with County staff prior to installation. 3. As per the West change proposal request, additional time to the contract will be determined at a later date. CPR#10 Added Column to Mezzanine $ 1,529.69 The following issues require this change order: Packet Pg.822 C.23.a 1) Due to noticeable deflection of the steel tube beam supporting the mezzanine on index line D a new column was installed as recommended and designed by the Architect. Prior to the fabrication and installation of the new column, post-shores were installed for temporary protection. 2) As per the West change proposal request, additional time to the contract will be determined at a later date. CPR#11 Decking for Canopies over Apparatus Bay Doors $ 33,266.83 cv cv The following issues require this change order: 1) The original plans for the roof canopies over the front and back doors to the apparatus bay consisted of structural steel brackets attached to the outside walls. As per the structural plans, these structural brackets were spaced about 4 feet apart along the wall and connected with horizontal steel brackets at the ends of the brackets. The Architectural plans provided limited 0 construction and finishing details—plywood was required for the top, covered with standing seam metal roof. Densqlass was specified for the soffit. No intermediate framing was specified. The building inspector noted that the lack of framing would not meet building code because the spacing between structural members was too great. The additional work, not included in the original design, required the addition of intermediate horizontal framing at the top and bottom of m the canopies to support the roofing materials and soffit, respectively as well as a adiustments to the finishing materials. 2) As per the West change proposal request, additional contract time will be determined at a later date. c cv cv CPR#12 Credit for Color Concrete $ (1,466.29) The following issues require this change order: 1) The original design called for exposed concrete floors throughout the station. The concreted was specified to include an added color dye. The primary concrete provider in the County, Monroe Concrete, would not allow color dyes to be added to their concrete, saying it would "void the warranty"for the concrete's strength and durability. Since the specified concrete color was "Gray", the color dye was omitted. The credit represents the price of the color dye additive. m 2) As per the West change proposal request, additional time to the contract will be determined at a later date. CPR#15 Lighting Fixture Color Change $ 2,160.25 The followinq issues require this change order: 1) The color and finish of the light standards were specified in the plans and specifications. Upon submittal, CPH, the Architect, had a few questions about product options for the vendor of the light fixture and the electrical subcontractor. The Architect requested one of the alternatives presented, however the option selected was a higher priced one. This price increase was not made clear until after the material had been delivered to the site for installation. Packet Pg.823 C.23.a 2) As per the West change proposal request, additional contract time will be determined at a later date. CPR#16 Relocate Hose Reels-Combine to Air+Power $ 10,244.69 The following issues require this change order: 1) Three sets of compressed air hoses and electric cords, along with their overhead reels were included on the plans. The location of the reels did not meet the requirements of the Fire Rescue Department, so a new location was requested. The original design called for separate air and electric reels. An alternate model, which combined both air and electric on the same unit were proposed and accepted by Fire Rescue as they would be more efficient to use and maintain. a, This change includes an upgrade to the newer model and relocation of all structural, air and electric services. 2) As per the West change proposal request, additional contract time will be determined at a later date. c CPR#17 De-Con Shower Fixture Change $ 1,203.48 m The following issues require this change order: m 1) The decontamination shower was originally designed with all plumbing embedded in the concrete block wall. As the structural CMU wall was being constructed, it was noticed that the wall for the U shower fixture was filled solid with concrete. The shower fixture and plumbing lines could have been wall-mounted, however this was not an aesthetic or easy to maintain option. This change provides a wall mounted shower fixture with plumbing lines and shower controls in a single c enclosed unit. '✓ cv 2) As per the West change proposal request, additional contract time will be determined at a later date. CPR#18 Steel Plates to Stabilize Stairwell Block Wall $ 7,903.69 The following issues require this change order: 1) At the bottom of the stairs from the mezzanine to the apparatus bay, the stairwell is enclosed by a m fire rated CMU wall. The plans originally called for L-brackets at the top of the wall which would be welded to the steel beam above. This arrangement by itself would have been very difficult to install fire-blocking. An alternate design was proposed to replace the L-brackets with welded steel plates and concrete dry-packing to meet structural and fire-rated requirements. This proposal was discussed with the Architect and the Building Inspector and approved. 2) As per the West change proposal request, additional contract time will be determined at a later date. CPR#19 Structural Fix for Generator Deck $ 19,826.82 The following issues require this change order: 1) After the Generator package was delivered and installed, it was found that the weight of the generator, plus a full tank of fuel, would exceed the design rating of the generator deck. The Packet Pg.824 C.23.a Architect and structural engineers at CPH investigate several options and proposed a retro-fit of structural steel, bolted into the existinq concreted. West provided temporary shorinq until the retro-fit can be installed. CPH has provided signed and sealed drawings for the retro-fit, which are attached to this change order. All construction materials and installations shall be conformant with the attached CPH Design. 2) As per the West change proposal request, additional contract time will be determined at a later date. CPR#20 Change door function with additional hardware $ 6,846.66 cv The following issues require this change order: m 1) The Door Schedule, provided in the original plans, were reviewed by the Fire Rescue Department and several modifications were requested. In addition to the-garage doors, there are two standard doors on the-ground level. The original plans and door schedule called for these doors to be Panic Bar operated from the inside with No Reentry from the outside when closed. The Fire Rescue asked that these two doors be changed to add a key operable handle on the outside to allow entry, via key only, from the outside. This would allow Fire Rescue personnel access to the apparatus bay without having to-go upstairs to enter the building and then back down stairs to the bay. Also, two doors at the top of the stairwell from the Admin area down to the Apparatus Bay were also originally scheduled for Panic Bar operation with no reentry from the stair well. Fire Rescue requested these also be refitted with key operated handles to allow for re-entry to the building from the Apparatus Bay to the Admin area of the building. 2) The lock hardware and lock cores for all doors were not specified to the County's current 0 standard, Best CoreMaxTM. This was corrected during the submittal review, but represents an 2 additional charge to meet the current specification. cv 3) As per the West change proposal request, additional contract time will be determined at a later date. CPR#21 Revision to Irrigation System $ 9,357.47 a The following issues require this change order: m 1) The original bid plans assumed that water service to the buildinq would come from the US-1 side. FKAA required that all water service come from the La Fitte side of the building. The Fire Station requires three (3) water service connections (and 3 meters). The site plan was revised for the domestic water and fire flow service connections and only required re-routing the mains from US- 1 to LaFitte. The connections to the building did not have to move. However the Irrigation plans were not revised until May 2020. The revised connection of the irrigation supply line required "flipping"the supply line size and connection from US-1 to LaFitte and some minor re-design of the irrigation layout. Also, the size specified for the irrigation meter was only 518 inch and a 1.0 inch connection was needed to meet flow requirements.. However, by May 2020, the parking lot was under construction and the sub-grade was installed prior to trenching for the irrigation lines. This required the paving contractor to have to stop and re-mobilize to fix the subgrade after the revised irrigation line was installed.. Additional work was required of the plumbing sub, the irrigation sub and the paving/site work sub. 2) As per the West change proposal request, additional contract time will be determined at a later date. Packet Pg.825 C.23.a CPR#22 Add Circuit for 61h Overhead Door Motor $ 1,334.37 The followinq issues require this change order: 1) The original Architectural and Structural plans show 3 pairs of-garage doors (6 doors total) and 6 total-gara-ge door openers alonq with structural attachment points. The Electrical plans show only 5 electrical circuits for the 6-gara-ge door openers. There were no inquiries prior to bid re-gardinq the discrepancy. The breaker panel has sufficient spare breaker space to accommodate the added circuit. Additional labor and materials are required to add the missinq circuit. cv 2) As per the West change proposal request, additional contract time will be determined at a later date. m CPR#23 Relocate the termination of the new IT Conduits $ 1,918.76 The following issues require this change order: 0 1) The original plans showed the IT fiber service cables cominq from the US-1 side of the project site at a location near the north side of the building next to the Apparatus Bay doors. Underground conduits for this service were shown entering the building and passing through the apparatus bay and up through the floor to the IT room. These plans also showed the electric power service for the building coming from the LaFitte side of the project site to the transformer and then to the electrical room. After service was negotiated with Keys Energy Service it was determine that electrical service would have to come from the US-1 side and require a new secondary pole. At that time the County IT department agreed with the network service providers to use that secondary pole and new conduit for the IT fiber cables. The Keys Energy contractor 0 provided the main conduit from US-1 to the building and pulled their fiber cable. The electrical 2 sub to West provided the conduit to make the final connection to the IT room. This was additional cv labor and materials not on the original plans. 2) As per the West change proposal request, additional contract time will be determined at a later date. CPR#24 Relocate Domestic Water Booster Pump Power $ 573.24 i The following issues require this change order: 1) The original plans showed the domestic water booster pump located outside the building near the entrance of the main service line. Prior to installation, the outside location was determined to be a maintenance problem. An alternate location, on the compressor platform next to the mezzanine, was selected. This new location was approved by the Architect/Engineer of Record. This required a minor relocation of conduit and electrical circuits. 2) As per the West change proposal request, additional contract time will be determined at a later date. CPR#25 Tile Corner in Lieu of Bullnose Tile $ 278.03 The following issues require this change order: 1) The ceramic wall tile specified for the kitchen and bath areas, and proposed by the Contractor, did not have a matching bullnose tile as specified in the original plans for terminating finish tile at door and wall edges and around windows. The Contractor recommended, and the Architect Packet Pg.826 C.23.a approved, the use of a color matched vinyl edge-guard to provide a finished edge at required locations. This change order is for the cost of materials only as installation was not an additional expense. 2) As per the West change proposal request, additional contract time will be determined at a later date. CPR#26 Upgrade Fuel Dispensing Hose to 100ft. $ 2,223.68 The following issues require this change order: cv 1. This is a County requested proposal to upgrade the fuel dispensinq system on the Generator fuel tank from the original specified 60 feet of hose with reel to 100 feet of hose plus (a larger) reel. The fuel dispensinq system was designed to allow fuelinq of Fire Rescue vehicles from the Generator fuel tank in times of emergency. The originally specified 60-foot hose would only reach one side of a vehicle parked in the closest spot available. The 100-foot hose will enable fuelinq of vehicles with fuel tanks on either side. 2. As per the West change proposal request, additional time to the contract will be determined at a later date. 0 cv cv i m Packet Pg.827 C.23.a CPRs #5, 21, and 22 Resulted from A/E errors but staff does not recommend pressing and E&O claim — the reasons are contained below CPR#5 Increased wall thickness of beam $ 2,568.95 CPR#21 Revision to Irrigation System $ 9,357.47 CPR#22 Add Circuit for 61h Overhead Door Motor $ 1,334.37 cv cv Change Order Attachment per Ordinance No. 004-1999 • Change Order was not included in the original contract specifications. Yes ® No ❑ If Yes, explanation: 0 CPR#5 - - The increase in beam wall thickness was added by the Architect upon review of the shop drawing submittal for structural steel. This increased the weight and cost of this beam. CPR#21 - - The bid set of plans did not include the correct location for all water service to the project site. CPR#22 - - The bid set of plans included only 5 circuits for the 6 garage door openers and did not m include a 6 dedicated circuit. • Change Order was included in the original specifications. Yes ❑ No If Yes, explanation of increase in price: c cv • Change Order exceeds $50,000 or 5% of contract price (whichever is greater). Yes ❑ No ® If Yes, explanation as to why it is not subject for a calling for bids: E i • Project architect approves the change order. Yes ® No ❑ If no, explanation of why: a)• Change Order is correcting an error or omission in design document. Yes ®No ❑ Should a claim under the applicable professional liability policy be made? Yes ❑ No ® c, Explain: CPR#5 -- The Architect caught the error in beam wall thickness during shop drawing submittal review and prior to fabrication and construction, resulting in only an increase in materials cost. CPR#21 - - Although the bid set of plans showed an incorrect location for water service, there was ample time for revisions to avoid the re-work required to put in the irrigation after the parking lot subgrade had been installed. This is poor management by the Contractor and was not the fault of the Architect. CPR#22 -- The 6th circuit for the 6th garage door opener was clearly omitted from the plans. However, it is not clear that the electrical sub would have only bid 5 circuits when it was easy to see that 6 garage doors needed to be functional. The omission should not have resulted in an increased price. Packet Pg.828 C.23.a CPRs #7, 10, 11, and 19 Resulted from A/E errors but staff will pursue E&O claim — the reasons are contained below CPR#7 Tower Dimensions Discrepancy $ 2,780.25 CPR#10 Added Column to Mezzanine $ 1,529.69 CPR#11 Decking for Canopies over Apparatus Bay Doors $ 33,266.83 CPR#19 Structural Fix for Generator Deck $ 19,826.82 cv Change Order Attachment per Ordinance No. 004-1999 • Change Order was not included in the original contract specifications. Yes ® No ❑ If Yes, explanation: CPR#7 - - The plans provided to all bidders contained a discrepancy in the dimensions shown on the architectural plans (Sheet A 1.0) versus the dimensions on the Structural Plans (Sheet S2.0) regarding the tower walls and elevations for the northeast corner of the building — at the main entrance. The original Structural details also did not provide clarity. RFI#26 addressed this discrepancy, however the 0 response from the Architect(CPH) was insufficient to resolve all dimensions. The forms for the beams m in this area were sized based on the structural plans, however these dimensions were 2 feet shorter than the dimensions on the architectural plans. Since the discrepancy only affected the projection of one short wall at the tower/corner, the contractor made the adjustment and increased the projection by 2 feet, including adjusting the reinforcing steel. No additional materials were required. This change order involved labor only. 0 CPR#10 - - Regarding the excessive deflection in the mezzanine beam, the Architect reviewed and approved the Contractor's shop drawings, including the location of field welds. Under load the installed beam was found to be deflecting excessively. The Architect recommended a new column to add support and provided revised structural plans. CPR#11 --Because the original design was incomplete, additional materials and work was required to properly install the framing, roofing and soffit materials for these canopies. CPR#19 - - The West-proposed generator package was based on the original basis of design and specifications. The original design was apparently based on only one generator package example weight—not the generator proposed by West(which was listed as the basis of design). m • Change Order was included in the original specifications. Yes ❑ No ® m If Yes, explanation of increase in price: • Change Order exceeds $50,000 or 5% of contract price (whichever is greater). Yes ❑ No If Yes, explanation as to why it is not subject for a calling for bids: • Project architect approves the change order. Yes ® No ❑ If no, explanation of why: • Change Order is correcting an error or omission in design document. Yes ®No ❑ Packet Pg.829 C.23.a Should a claim under the applicable professional liability policy be made? Yes ® No ❑ Explain: CPR#7 - -As described above, there was a clear discrepancy in the plans between the architectural and structural sheets. This discrepancy was exacerbated by conflicting information contained in supporting structural details. The contractor used the structural plans and details to form the building beams and floors. This discrepancy was not discovered until a late stage in the project, after the structural beams had been formed (but not poured). The wall construction in this area was being planned and the dimensions did not match. CPR#10 - - Regarding the excessive deflection in the mezzanine beam, the Architect reviewed and approved the Contractor's shop drawings, including the location of field welds at an intermediate column. cv CPR#11 -- The original design was incomplete and not conformant with applicable building codes CPR# 19 -- The design load of the original generator deck did not meet the actual weight of one of the commercially available generator packages that were listed in the plans and specifications as the basis of design. The retro-fit and repair costs of this change order will greatly exceed the cost of a minor increase in concrete and reinforcing steel that would have been needed if the original design had been sufficient for the weight of all possible generators specified for this project. The retrofit itself and the cost of the repairs do not add value to the project. m 0 cv cv i m Packet Pg.830 C.23.a CPRs # 8 & 18 Resulted from Scope items included in the original bid but for which staff requested changes CPR#8 IT System Furnish &Install $ 13,822.90 CPR#18 Steel Plates to Stabilize Stairwell Block Wall $ 7,903.69 Change Order Attachment per Ordinance No. 004-1999 ~� N CD • Change Order was not included in the original contract specifications. Yes ® No ❑ If Yes, explanation: , CPR#8 -- The original plans did not include conduits and cabling for network and telephone systems. After award, the County worked with the IT Department and Fire Rescue to locate required data and telephone jacks. The Contractor was asked to provide a proposal to furnish and install these IT components. m CPR# 18 - - The design was determined to be difficult to construct and meet all requirements. The proposed change will meet all structural and fire rating requirements, while provided added value in the form of reduced long term maintenance m • Change Order was included in the original specifications. Yes ❑ No If Yes, explanation of increase in price: 0 CD • Change Order exceeds $50,000 or 5% of contract price (whichever is greater). Yes ❑ No cv If Yes, explanation as to why it is not subject for a calling for bids: • Project architect approves the change order. Yes ® No ❑ i If no, explanation of why: . m • Change Order is correcting an error or omission in design document. Yes ❑No m Should a claim under the applicable professional liability policy be made? Yes ❑ No Explain: Packet Pg.831 C.23.a CPRs # 12,15, 16, 17, 20, 23, 24, 25, & 26 are scope items not included in the original bid but for which staff requested changes CPR#12 Credit for Color Concrete $ (1,466.29) CPR#15 Lighting Fixture Color Change $ 2,160.25 CPR#16 Relocate Hose Reels-Combine to Air+Power $ 10,244.69 CPR#17 De-Con Shower Fixture Change $ 1,203.48 cv CPR#20 Change door function with additional hardware $ 6,846.66 CPR#23 Relocate the termination of the new IT Conduits $ 1,918.76 CPR#24 Relocate Domestic Water Booster Pump Power $ 573.24 CPR#25 Tile Corner in Lieu of Bullnose Tile $ 278.03 m CPR#26 Upgrade Fuel Dispensing Hose to 100ft. $ 2,223.68 0 m Change Order Attachment per Ordinance No. 004-1999 • Change Order was not included in the original contract specifications. Yes ❑ No 0 If Yes, explanation: cv • Change Order was included in the original specifications. Yes ❑ No If Yes, explanation of increase in price: • Change Order exceeds $50,000 or 5% of contract price (whichever is greater). Yes ❑ No If Yes, explanation as to why it is not subject for a calling for bids: m • Project architect approves the change order. Yes ® No ❑ If no, explanation of why: • Change Order is correcting an error or omission in design document. Yes ❑No Should a claim under the applicable professional liability policy be made? Yes ❑ No Explain: CPR#20 -- The original plans and specifications included a Door Schedule and lock core specification but did not meet the most recent County standards for lock specifications. There is no evidence that the Architect was given the latest standards during design. CPR #23 - - The change in location from where to locate the IT Fiber Service cable was based on a County decision. CPR#24-- The new location of the booster pump improves long term maintenance and life cycle costs and therefore represents value added to the building. Packet Pg.832 MONROE COUNTY/ENGINEERING/ PROJECT MANAGEMENT CONTRACT CHANGE OIWER PROJECT TITLE: CHANGE ORDER NO: [M1 Plantation Key Courthouse& Detention Center INITIATION DATE: November 1A, 2Q20 COMMENCEMENT DATE August 5. 2018 CONSTRUCTION DAYS: 913 TO CONTRACTOR DAYS ADDED TOCONTRACT: 128 BUtmnoro Construction Company 1055 Ponce De Leon Blvd CD BmUeair. FL33756 nw The original(Contract $ 32,81O.441.14 o Net change by previously authorized byAmendments $ 2"096.900.34 Net change by previously authorized Change Orders $ (3.098.164.15) ^ The (Contract SUM) ( prior io0hiu Change order was $ 31,817,287.83 The (Contract Sum) (Guaranteed will be (incroaoed)(decreased) (unnhange4 � by this Change Order by $ (83.971.92) The new(Contract Sum) ( ) including this Change Order is $ 8�.738.295.41 The{�omtmmotTime will ba(incneaood) (deumaaued) (�cyan�d8by --------- 0 0Tbodatoof8ub�an�o| Comp|otionuponapprova|of1his{�honyaO ----------- June 1i. 2O22 Monroe County wishes to purchase the carpeting materials directly from the supplier to take advantage of the County's tax free status. The GMP will be reduced and the funds will then be used to procure the same materials via a purchase order from OMB (attuuhed) " This Change Order is: '8.26% of the original contract price Not valid until signed by Owner,Architect(if applicable), and Contractor � ARCHITECT/DESIGNER: Date CONTRACTOR: Date Digitally signed by Cary »r^ �� ^ �~4� Knight �~��r�� ����U��K0 � Date:2020]l20lh:3l:5V ~ .— . {D.0 � DIRECTOR OF PROJECT MANAGEMENT: °~ cn=Kevin G.Wilson,P.E., Date o=wmnme County,FL(the Florida Keys,ou'eman=wi|mn' / 7 kevn@nonmemunty-flgovo~os - �� COUNTY0A8SlSTANTADKH|N|GTRATOR zozo. .z4nx3us*s'oo' C.23.a CHANGE ORDER LEDGER � vgt� PLANTATION KEY COURTHOUSE & DETENTION CENTER r , 4x 4/14/2020 38 Days (3,182,336,07) N - - N NMI 01 ODP Generators 0 $ (684,007.00) 02 ODP PKG Lighting 0 $ (986,135.21) 03 ODP Gypsum 0 $ (235,144.21) 04 ODP Concrete 0 $ (80,000.00) 05 ODP FIVAC 0 $ (213,360.00) 06 Site Survey Delay 38 $ 07 ODP Hollow Metal Door 0 $ (88,088.00) � 08 ODP DuosTech 0 $ (591,672.00) 09 ODP New Millennium Steel 0 $ (129,888,00) as 10 ODP Roofing Material 0 $ (89,869.73) 11 ODP Tarkett Flooring 0 $ (83,971.92) 0 CD c44 CD cv W CD m ca Packet Pg.834 C.23.a MONROE COUNTY PURCHASE ORDER NO. 00062397 BOARD OF COUNTY COMMISSIONERS ,. 1100 Simonton Street, Suite 2-213 PAGE NO. 1 Key West„ FL 33040 SALES TAX EXEMPT NO.:85-8013825294C-7 P Q F COPY V [-98739 H F M.c. PROJECT MANAGEMENT E TARKETT USA INC I 1100 SIMONTON ST, 2ND FL RM 2-215 CD N 30000 AURORA ROAD P KEY WEST, FL 33040 a SOLON OH 44139 RL I O ORDER DATE:09/11/20 BUYER: B ERICKSON REG.NO.: 00057065 REQ.DATE: TERMS: NET 30 DAYS F.O.B.: DESC.: ITEMN QUANTITY UOM I DESCRIPTION UNIT PRICE EXTENSION 01 1. 00 LOT OWNER DIRECT PURCHASE .0000 ._0_i CARPET MATERIALS FOR THE PLANTATION KEY ' COURTHOUSE AND DETENTION CENTER 02 703 .00 SY PLEXUS COLOUR IV, IRON AGE ON POWERBOND 29.1200 20,471.3 m 6' CUSHION 03 35.15 SY PLEXUS COLOUR IV, IRON AGE ON POWERBOND 29.1200 1,023 .5 6 ' CUSHION (UP TO) 5 m OVERAGE CJ 04 986 .00 SY CUSTOM JASPER, CLAYSTONE ON POWERBOND 6 " "31,4200 30, 980 .1 CUSHION # 111417663-10 05 59. 16 SY CUSTOM JASPER, CLAYSTONE ON POWERBOND 61 31.4200 1, 858. 8 CUSHION #111417663-10 (UP TO) 64 OVERAGE 06 B89.00 SY WINWOOD, CLAYSTONE ON POWERBOND 6 ' 28. 0100 24, 900. 8 ' CUSHION 07 44.45 SY WINWOOD, CLAYSTONE ON POWERBOND 6 ' 28.0100 1,245. 0 CUSHION (UP TO) 5 o OVERAGE 08 7. 00 QT C L SEAM WELD 14 .1100 98.7 09 54 . 00 4 GAC16E ADHESIVE FOR POWERBOND 62 .8400 3,393 .3 10 1. 00 LOT SHIP TO ADDRESS . 0000 .0 � CARPET SERVICES OF TAMPA, INC 1308 NORTH WARD STREET, 'PAMPA, FL 33607 ¢I I � ITEMN COST CENTER ACCOUNT PROJECT PROJECT ACCT AMOUNT PAGE TOTAL $ 83, 971«92 01 26008 560620 CP1503 530340 .00 TOTAL 83, 971. 92 02 '26008 560620 CP1503 530340 20,471.36 03 26008 560620 CP1503 530340 1,023.57 04 26008 560620 CP1503 53Q340 30,980.12 05 26008 560620 CP1503 530340 1,858.81 06 26008 560620 CP1503 530340 24,900.89 07 26008 560620 CP1503 530340 1,24504 08 26008 560620 CP1503 530340 98..77 PARTIAL PAYMENT 09 26008 560620 CPIS03 530340 3,393.36 10 26008 560620 CP1503 530340 00 FINAL PAYMENT INVOICE NO. INVOICE AMOUNT PAYMENT DESC. PAYMENT APPROVAL PURCHASING AGENT Packet Pg.835 MONROE COUNTYANGiNmum/ PROJECT MANAGEMENT CONTRACT CHANGE ORDER PROJECT TITLE: Cato Building Roof Replacement CHANGE ORDER NO: I INITIATION DATE: December 15,2020 TO CONTRACTOR: CONTRACT DATE:April 15,2020cV Triple M Roofing Corp. 914 NW 191 Avenue Fort Lauderdale, Florida 33311 E The Contract is changed as follows: The original (Guaranteed Maximum Price)...........................................$803,600.00 0 Net change by previously authorized Change Orders............... ............... ...... ...........$o.00 0. The(Contract Sum) (Guaranteed Maximum Price)prior to this Change order was......... ..$803,600.00 The(Contract Sum) (Guaranteed Maximum Price)will be (in 2MMedl(decreased) (unchanged)by this change Order........... .......$8,683.50 0 The new(Contract Sum)(Guaranteed Maximum Price) including this Change Order is......$812,283.50 a) The Contract Time will be(increased) (decreased)(unchanged)by........................_... 90 days The date of Substantial Completion as of the date of this Change Order is..................... February 28, 2021 Detailed description of change order and justification: The increase of this Change Order is for additional work re aired to be performed on the existing electrical 0 conduit which is attached to the roof for the operation of the Gato Building elevator. In order late the E� roof work, electrical conduit used for the elevator must be dismantled and relocated. The original substantial coLnpletion date was November 30, 2020. Due to an ex ected de/ay of getting the subcontractor onsite, the substantial coMpletion date is being extended for 90 da s. E This char -der is 1.1%of the oricinal contract price. Not valid until signed by Owner.Architect(if applicable),and Cont 0.. A", David Salay ARCHITECT: 12115/20 0 Be -er&A so to It Date a) CONTRACTOR: riple M Roofi Grp.n Dat Digitally signed by Cary Knight DIRECTOR PRO JECT MANAGEMENT Cary K ght Date:2020.12.16 11:03:31-05'00' E Cary Kniaht Date cn Kevin G.W[I son,P.E.,.—Monroe C.-ty,FL(,he Florida Keys,ou,email—wilson levn ,,nr,=ty 1.gov,-Us COUNTYIASSISTANT ADMINISTRATOR: ,,202012 sr'0 12.17 14 05'00' Roman Gastesi Date Kevin Wilson Christine Hurley Packet Pg. 836 C.23.a Change Order Attachment per Ordinance No. 004-1 99 Change Order was not included in the original contract specifications. Yes Z No El If Yes, explanation: The existing electrical conduit which serves the building elevator needs to be relocated in order to complete the roofing work. This work must be performed by a specialized elevator contractor. This work was not recognized prior to bidding. Change Order was included in the original specifications. Yes o If Yes, explanation of increase in price: m Change Order exceeds$50,000 or %of contract price(whichever isgreater). Yes El No m If Yes, explanation as to why it is not subject for a calling for bids: 0 Project architect approves the change order. Yes Z No 2 If no, explanation of why: cv Change Order is correcting an error or omission in design document. Yes o 0 Should a claim under the applicable professional liability policy be made? Yes El No Mi Explain: m m Packet Pg.837 C.23.a *IM= CONT ACT'- GE ORDER 001 914 MW IM StreetProject: t f Replacement t.Lauderdale,Florida 33311 Address 1100 SimontonStreet Phone: 24-7000 City Key West ITB No. Fax: t ®Zip Code FloridaProject CONTRACT CHANGE ORDER cv c44 t i r: Maverick United Address 500 Whitehead t Elevator Repair City/State/Zip t dated: April 15, 2020 Date ® J11/ c Attention: Michael DeAngelisi Order: DESCRIPTION AND SCOPE OF WORK: a) ElevatorMaverick United it $ 8,270.00 Mark-up1 . Profit - Subtotal $ ° 50 ® Total $ 8,683.50SC HEDULEIMPACT ®The schedule will impacted by an additionalf, days originalThe 803,600.00 Not change by previously authorized Change Orders $ 0.00 ¢i The contract sum prior to this r The contract sum ill be IncreasedideeFeamdy this Change Order in the amount of $ 8,683.50 The new contract sum including this it 1 , The contract time willAN111 not be change by this acceptanceUpon i r by signing below,this change amendes the contract between the parties. r riple M Roofing Corp 12JI Signature Date ., rData Print Name&Title: Jarvis, € n c r Packet Pg.838 C.23.a UnITC-3 .- y � >'rrF,���111� ...: ............... .. ,.... . . N CD ELEVATOR REPAIR E Project Name: Maverick United Elevator LLC, Gate Building 0 1100 Simonton St, Key West FL 10639 1 St Medley, FL 3173 cnt �tw Miguel A. Garcia Cell;305 510 8272 ichaei DeAngelis Fax®305 888 7599 a) (1)Elevator, ( ) landings, 2500 lb. www.Maverickunitedelevator.com CJ Ernaila Info@mavelevator.com 0 Purchaser authorizes Maverick UnitedElevator to perform the following described repair work on the CD subject elevator(s)in the above building: CD N N Scope of Work Elevator Wiring i • Dismantle existing piping that is obstructing the roof work • Furnish and install new hoist way and car wiring • Furnish and install new traveling cable from outside of the elevator machine room • Provide additional wilring for connection m • Relocate the piping that is running on the roof • Provide a new-cables for the min line of the elevator a Provide the necessary repair to the • Test elevator for normal service Existing wiring needs to be removed in order for the roofing work to continue, existing elevator � has timers as result of that there is a possibility that it could lock itself or lases the memory in that event, we will inform you, any additional cost will be past on in the form of a change order Total Cost: Eight Thousand 1 4 Packet Pg.839 C.23.a TAXES,PERMITS,TESTING,AND FEES e included taxes where applicable,permits,testing requirements and testing fees. WORKINGS All work is based on the normal working hours of the elevator trade and no overtime hours are considered. PAYMENT SCHEDULE 1. The first 60A contract amount is to accompany a signed and datedcopy of this proposal.No work will be scheduled or material ordered until the signed proposal and first payment are received. 2. The next 4 % of the contract amount ill be due upon completion � ACCEPTANCE , returned copy of the proposal,properly signed and dated and approved by Maverick United Elevator shall constitute the contract between us and will be our authorization to order materials and schedule the work. CONTACT Please direct any questions or areas of concern to the undersigned, CONTACT m Please direct any questions or areas of concern to Maverick United Elevator It is understood that Maverick United Elevator ( e"Company")will arrange to Install the material necessaryto complete your joband shall be (, upon you or your authorized representative signing the final acceptance that the Installation Is satisfactory and complete. Youagreetopaythe _ Company the amount specified above which will cover the costs of labor and materials.Should It become necessary to collect any of the ¢ money due us under this agreement with you,through an attorney,then you shall pay all cost of collections,Including a reasonable attorney's fim Any changes made by you In the above specifications sitating additional labor or materials shall not be Included or covered by this proposal,but shall be provided for In a separate and additional signed agreement by both partles. There shall be no liability for delays due to causes beyond our control, Accounts in arrears thirty(30)days will be assessed a monthly service charge of 1.5 This proposal and payment CV agreement shall be the whale agreement between the parties and shall not be altered except by written agreement.Inconsideration of the Q performance of the services and the furnishing of the materials,it Is expressly understood that the Company assumes no liability for accidents, Injuries to persons or damage to property occurring on or near any part of the elevator system which Is the subject of this Agreement regardless of the cause of any such accident,bodily injury or property damage and regardless of any negligence upon the part of the Company, Its employees or officers,You agree to Indemnify,defend,and hold harmless the Company,Its officers,agents and employees from and against any and all claims,demand,suits and proceedings brought against the Company or its officers,directors,or employees of any nature whatsoever,Including but not limited to claims and lawsuits far losses of any kind,property damage,personal injury or death that are allegedto ¢I have arisen from or alleged to be connected with the presence,use misuse,maintenance,installation,removal,manufacture,design, operation or condition of the equipment covered by this Agreement,specifically including claims or losses alleged or proved to have arisen from the partial or sole negligence of the Company or Its officers,directors, or employees.YOU expressly agree to name Maverick United Elevator as an additional named insured on your liability insurance policies, it Is understood that the elevator,at all times,is owned by you and that you are solely responsible for Its safe operation. a) CD Proposed: Accepted:_ ,t s r Miguel A Garcia a s fit' i r7 )" 9 Accounts Rep F Maverick United Elevator Title: d ."� Date: ate° ,. r1'= A . Packet Pg.840