Item C02 BOARD OF COUNTY COMMISSIONERS AGENDA ITEM SUMMARY MEETING DATE: December 18.2002 DMSION: Public Works Division BULK ITEM: Yes .K- No_ DEPARTMENT: Detention Facility AGENDA ITEM WORDING: Approval to waive purchasing policies and issue a Purchase Order to Siemens Building Technologies, Inc. for $27,750 to upgrade the Firefighters Smoke Control Station at the Detention Facility on Stock Island. ITEM BACKGROUND: The Firefighter's Smoke Control Panel automatically operates smoke evacuation and control fans within zones throughout the jail facility when a particular fire alarm zone is activated. The station was constructed by Siemens with the latest technology at the time, but it is now yesterday's technology with components that are beginning to fail and are no longer being produced. In order for the panel to serve its function, its components have to be compatible and communicate with the existing Building Automation System. Every building control provider has their own components and protocols built into their systems that are not duplicated by other providers; therefore, Siemens is the sole source provider to properly upgrade this system. PREVIOUS RELEVANT BOCC ACTION: none CONTRACT/AGREEMENT CHANGES: nla STAFF RECOMMENDATION: Approval as stated above, TOTAL COST: $27.750.00 BUDGETED: Yes:...1L No: Account No. 101-20505-530460 COST TO COUNTY: same REVENUE GENERATED: no APPROVED BY: Co. Atty,:_ OMBlPurchasing:_ Risk Management: _ DMSION DIRECTOR APPROVAL: [) J-{? UM:L 16e Dent Pierce , DOCUMENTATION: INCLUDED:-X- TO FOLLOW: NOT REQUIRED: DISPosmON: AGENDA ITEM #: ~rJ_ MEMORANDUM DATE: NOVEMBER 5,2002 ( ~O~ TO: FROM: RE: DENT PIERCE, PUBLIC WORKS DIVISION DIRECTOR _(h, BOB STONE, MIDDLE KEYS OPERATIONS DIRECTOR Y ( UPGRADE OF FIREFIGHTER'S SMOKE CONTROL PANEL AT THE MONROE COUNTY DETENTION CENTER Attached is a proposal from Siemens Building Technologies, Inc. which outlines the scope for replacement of the existing obsolete fire smoke control panel at the Monroe County Detention Center on Stock Island. Also, attached from Siemens is a cost breakdown for this work and a letter describing the system, along with why Siemens would be considered a sole source. Unfortunately, this panel was constructed with the latest technology at the time but now it is considered yesterday's technology with components that are no longer being produced that are beginning to fail. The Firefighter's Smoke Control Panel" is considered a life safety component that automatically operates smoke evacuation and control fans within zones throughout the jail facility when a particular fire alarm zone is activated, The panel can also, be operated manually by a firefighter or other trained personnel to manipulate smoke evacuation throughout the facility, In order for the panel to serve this function, its components have to be compatible and communicate with the existing Building Automation System, Every building controls provider have their own components and protocols built into their systems that are not duplicated by other providers. Therefore, it is apparent that Siemens is the only company that would be able to properly replace the required Firefighter's Smoke Control Panel. Due to the sole-source nature of this system, waiver of the existing purchasing policies for the competitive bidding process is requested for its purchase. If there are any questions of if more information is desired, please do not hesitate to contact this office, SIEMENS August 21, 2002 Monroe Detention Center 5100 College Road Key West, Florida 33040 Attention: Bob Stone Reference: Firefighters' Smoke Control Station Dear Mr. Stone: With this letter, we are providing certain information pertaining to the Firefighters' Smoke Control Station (F.S.C.S.) that was installed with the original construction of the Monroe Detention Center on Stock Island. At its core, this panel is essentially a Remote Control Unit (R.C.U.), which was a product of a precursor of Siemens Building Technologies (S.B.T.). Internally, R.C.U. 's are composed of several electronic assemblies, including "line cards" and "function cards". These cards were assembled using certain electronic components that are no longer being produced by their manufacturers. Therefore, S.B.T. can no longer produce the line cards and function cards that may be necessary for the repair of an R.C.U. Siemens Building Technologies is currently producing direct digital control (D.D.C.) panels that are known as Modular Building Controllers (M.B.C. 's). In addition to incorporating m?ny advanced features, Modular Building Controllers also include all of the functionality of the obsolete Remote Control Units. Modular Building Controllers are now being used as the technological core of the F.S.C.S. panels that are being currently provided by Siemens Building Technologies. For the Firefighters Smoke Control Station to fulfill its intended function, it must be capable of communicating with the other direct digital control panels of the facility's Building Automation System. The F.S.C.S. must be capable of functioning as a cohesive system with the other D.D.C. panels of the building. Because of the unique protocol that is used for communication between the control panels of the D.D.C. System at the Monroe Detention Center, this capability is assuredly present only in D.D.C. panels that have been manufactured by Siemens Building Technologies. The F.S.C.S. is essentially a D.D.C. panel. If the existing R,C.U.-based F.S.C.S. is to be replaced, then it can be replaced suitably only by a panel which has been manufactured by Siemens Building Technologies. 0.0~ Stit1Ce'yelY,. I . I . I V..~ ~.l ~VL,--? W. Todd Harris Account Executive Siemens Building Technologies, Inc, Landis Branch Network 10111 Business Drive Miramar, FL 33025 Tel: (954) 442,6200 Fax: (954) 431-6740 -~~"~'1~ .LIU.&.L...LI.&.11U IIU I unn 1.1. vv'"T"T..:JJ.O ''''U f'.c: SIEMENS . Monroe County Public Works . 10600 Aviation Boulevard . Marathon, Florida 330GO SERVICE PROPOSAL Date: Limiting: November 05, 2002 necember 04. 2002 Attention: Bob Stone Project Monroe Detention Center: Upgrade of Firefighter's Smoke Control Panel Proposal: Siemens BuilcJillY Technologies, Inc., Landis Division, proposes to provide an upgrade of the t=irefightAr'!; Smoke Control Station (FSCS) at Monroe Detention Center. A purpose of this upgrade is to provide for the modernization of the internal configuration of the panel, thus replacing the panel's obsolete electronic components for which, in me event of failure. I t:placel11cnt parts are no longer being monuf3ctured.. This proposal includes: Modernization of the FSCS's internal configuration. using components that are currently in standard production, and eliminating components that have become obsolete and irreparable; Replacement of the FSCS's panel face with one that more precisely complies with current NFPA guidelines requiring C:l Yl l:Iphical depiction of the smoke control equipment and ductwork of the building; Addition of control and monitoring features to the FSCS to provide the capability for firefighters to monitor and override the automi:ilil.; ~moke control sequences of the Juvenilo Detention Facility which is now being constructed immediately adjacent to the Monroe Detention Center; End-la-end testing of each switch and lamp of the FSCS after completion of installation. This proposal also inclUdes: Design & Engineered Drawings; Programming, Start-up, and Check-out; Operations & Maintenance Manuals; On-site Training (two hours) of Owner's Operational/Maintenance Staff; Standard One-Year Warranty, This proposal excludes: Any additional devices and sensors for control or monitoring of remote equipment; Any repairs for devices and sensors for control or monitoring of remote equipment; Any work pen'ormed outside of normal WOlkiny hours; Any testing to be required by the Owner or the Authority Having Jurisdiction; Government-imposed fees required to obtain building permits. Total Investment: Twenty-Seven Thousand, Seven Hundred Fifty Dollars ($27,750.00) This price does not include Florida sales tax. if applicable. Control Wiring: 111 Wiring by Siemens Building Technologies, Inc, D Wiring by Others 0 No Wiring Required Terms of Payment [KI Monthly Progress Payments 0 Retainage of _ % D Advance Payment of _ % The Terms and Conditions of Sale shown on the attached are a part hereof Proposal Accepted: Si~mens Building TeChnologies. Inc.. is authorized to proceed with the work as proposed. Purchaser By Title Date Proposal Submitted: Siemens Building Technologies. Inc. Seller By Title Date Siemens Building Technologies, tnc. Siemens Building Technologies, Ine. This proposal is valid until 04-DEC-02 Page 1 of 2 , 0111 Ihlsin~~, Dfivc Mir;;.,mu, ~L 33025 Tel: (9<;4) 441-6200 ~,)X: (95<1) 411 6740