Loading...
Release of Contingency Funds #114 BOARD OF COUNTY COMMISSIONERS County of Monroe . Mayor Holly Merrill Raschein,District 5 The Florida Keys Mayor Pro Tem James K. Scholl,District 3 h Craig Cates,District 1 Michelle Lincoln,District 2 David Rice,District 4 Memorandum DATE: 04/02/2024 TO: BOCC Digitally signed by Kevin G.Wilson,P.E. FROM: Kevin G. Wilson, P.E. i,. lu�_'° 4.- Date:2024.04.02 10:50:58-04'00' SUBJECT: Release of Contingency Funds Included with this memo is the proposed Release of Contingency Funds 4114 for the Fl Keys Marathon Airport Non-Aeronautical Use Building (EOC)project. This does not affect the contract amount, but releases contingency funds already included in the Guaranteed Maximum Price for work that was either not foreseen or for which a price could not be determined at the time of contract execution. The amount requested is $836.74. The attached Release of Owner Contingency Request provides the details. This is being provided to ensure the BOCC is aware of this change. Please contact me with any questions. If there are none with the normal 24-hour window, I will approve the request. County of Monroe m,� BOARD OF .;ONIXIIIONI tJ�ul� �/a� RS The Florida Keysa�" Alayor s ` James K. Scholl,District 3 Cra"I'll Cates District I �e Ise1,4e Uncsa1e District 2 David Rice,District 4 MEMORANDUM DATE: 3/7/2024 TO: County Administrator FROM: Cary Vick SUBJECT: Release of Contingency for: FL KEYS MARATHON AIRPORT NON- AERONAUTICAL USE BUILDING (EOC) Action Requested: Approval for RELEASE of contingency funds in the amount of $ 836.74 as outlined below. Basis for Recommended Action: 1. The requested release does not increase the total cost of the project as approved by the BOCC, and it will have no impact to contract time. 2. The scope for which the release is requested is within the intended project scope. 3. The release is not based upon an error or omission by the designer or the general contractor. Background: This is a cost change to the Contingency related to RFI 191, dated 05/10/2023, to furnish and install an extension cable for the sump pump alarm in order to reach the selected locations in the RFI 191 sketch. Extension cables are custom from the sump pump manufacturer. Approved by Mickey Pruitt Approved by Marshall Quarles 03/07/2024 10:00:16 AM 03/07/202410:11 :38 AM Ajax Building Company Architects Design Group ................................................................................................................................. APPROVED � Digitally signed by Kevin G.Wilson, w _ P.E. By Cary Vick at 10.40 aar=07, Date:2024.04.04 05:21:00-04'00' Cary Vick,Interim Project Management Director Kevin Wilson,Acting County Administrator Project: Marathon EOC Description of Change: Extention Cable for Elevator Sump Date: 2/20/2024 LABOR uantit Units Description unit Cost of labor #VALUE! Labor Subtotal #VALUE! Labor Burden Percentage 29% #VALUE! Labor Total $MATERIAL,(SUPPLIER BACK-LIIP ItECIUIRECI) uantit Units Description unit Cost of Material 1 ea 25' Extension Cabel $ 782.00 $ 782.00 Material subtotal $ 782.00 Material Sales Tax 7.50% $ 54.74 material Total 836.74_'� uantit Units Description unit Cost of E/S/U Labor Total $ - MateriaC total $ 836.74_'� i SWk)k,0:,fl $ 836.74 �,r III 2Cilili� �171t: load hig (it, ((,) AllowableOH&P 1.00................................................$...............................................................................................................8.3...6.7........................................ GRAND TOTAL(no pennies) $..........................................................................�. C.................... Wastewater Solutions LLC WASTEWATER 102 NE 2nd Street Suite 510 SOLUTIONS LLC Boca Raton, FL 33432 US (954) 483-9269 arturoCc wws-Ilc.com wws-Ilc.com INVOICE BILL TO SHIP TO INVOICE# 2046 GARY CENTORIZE MARSHALL QUARLES DATE 02/20/2024 6409 2ND JEN#1 Marshall Quarles DUE DATE 02/20/2024 KEY WEST, FL 33040 7280 OVERSEAS HWY TERMS Due on receipt US Marathon, FL 33050 US QUOTE# 9879 DESCRIPTION QTY RATE AMOUNT Stancor:8-Pin/25 1 782.00 782.00T 8-Pin Cable, 25' length extension cable with quick connect Freight Allowed el 1 0.00 O.00T ,�o Thank you for your business! ���,� � SUBTOTAL 782.00 TAX 54.74 TOTAL 836.74 PAYMENT 836.74 BALANCE DUE $0.00 Ajax Building Company,LLC Project:202011 Monroe County FL Keys Marathon 109 Commerce Blvd Airport NAUB EOC Oldsmar, Florida 34677 7280 Overseas Highway ,AIM P:+18137923900 Marathon, Florida 33050 RFI #Con-191 : Elevator Sump Pump Clarification Status Closed on 05/10/23 To Devon Ayers(K2M Design) From Jeffrey Whipple(Ajax Building Company, LLC) Mickey Pruitt(Architects Design Group) 424 SW 7th Terrace Gainesville, Florida 32601 Date Initiated Mar 7,2023 Due Date Mar 12,2023 Location Project Stage Course of Construction Cost Impact TBD Schedule Impact TBD Spec Section Cost Code Drawing Number P-001, P-401 Reference Attached RFI Linked Drawings E-101, P-100 Received From Jeffrey Whipple(Ajax Building Company, LLC) Copies To Giselle Albisu(TLC Engineering Solutions(Jax)), Devon Ayers(K2M Design), Frank Dittrick(TLC Engineering Solutions(Jax)), Victor Carrasco(TLC Engineering Solutions(Jax)), Erick Gonzalez(TLC Engineering Solutions(Jax)), Nathy Grullon(Architects Design Group), Donald Harcrow(Ajax Building Company, LLC), Cary Knight(Monroe County),Travis Mauldin(Ajax Building Company, LLC),Juan Perez(TLC Engineering Solutions(Jax)), Mickey Pruitt(Architects Design Group), Marshall Quarles(Ajax Building Company, LLC), Banistka Rodriguez(Architects Design Group),Jordan Salinger(Monroe County), Denise Saltzman (TLC Engineering Solutions(Jax)),Steven Sanders(Monroe County), Daniel Taylor(Architects Design Group),Cary Vick (Monroe County),Jeffrey Whipple(Ajax Building Company, LLC) Activity/ Question Question from Jeffrey Whipple Ajax Building Company,LLC on Tuesday, Mar 7, 2023 at 04:03 PM EST Drawing P-001 depicts the elevator sump pump to be a Stancore Model SE-40 O/M. (see attached cut sheet). Drawing P-401 depicts the elevator sump pump to be a Zoeller package system model#940-0006. (see attached cut sheet).The Stancore pump is what has been priced and included in the fixture submittal. Please advise on which model is desired. Additionally,the remote alarm panel for either system will require a GFCI receptacle nearby to power it as depicted on P-401 (see attached). Please provide the preferred location for this alarm panel and associated power. Provide recommended panelboard and circuit number to feed these GFCI receptacles please. Attachments Stancore Pump.pdf, RFI 191.pdf,Zoeller Pump.pdf Official Response Response from Mickey Pruitt Architects Design Group on Wednesday, May 10, 2023 at 02:40 PM EDT Revised response attached. Attachments 120825_Response_RFI Con-191.1 Elevator Sump Pump Clarifcation.pdf All Replies Response from Mickey Pruitt Architects Design Group on Wednesday, May 10, 2023 at 02:40 PM EDT Revised response attached. Attachments 120825_Response_RFI Con-191.1 Elevator Sump Pump Clarifcation.pdf Ajax Building Company, LLC Pagel of 2 Printed On: May 10,2023 05:50 PM EDT nr|#Con-1o1 'Elevator Sump Pump Clarification Project:000011 Monroe County pL Keys Marathon Airport mxuasoC Response from Devon Ayers noM Design on Monday Apr 24, 2023at/z32FMEDT See TLc'o response from M|okey'oresponse. Response from Mickey Pruitt Architects Design Group on Monday,Apr 10, 2023 at 08:43 AM EDT See TLC response attached.Aoo has no objection for the alarm locations. Attachments 120825-MONROE_COUNTY_EOC-Con-191-E|evator_Sump_Pump_C|arihcation-2023-04-1O.pdf Ajax Building Company, uc Page oo,o Printed On: May 1o.00000nooPM EDT q� IMM, xma poffisp S L ' } T I f 'r �"4 °arm RFI Response Con-191.1 RFI# Con-191.1 Reviewer: Victor Carrasco Project: 120825 - MONROE COUNTY EOC Received: 04/12/2023 Name: Elevator Sump Pump Clarification Returned: 04/20/2023 Please Note: The following RFI response is not intended to authorize any deviation or modification to the design documents except as specifically clarified below for this specific application and circumstance. Furthermore, this response is not intended to authorize any increase in construction cost, schedule or time extension, or construction in conflict with any applicable codes or specified design standards. It is the responsibility of the Contractor to notify the design team immediately of any perceived scope, schedule, or cost impacts or adjustments. Attachments 120825 RF1 Con-1 91.1 Elevator Sump Pump Clarification.iDdf Questions Attached are additional comments made on 04.12.23 to RFI Con-191 Elevator Sump Pump Clarification for your review. Comments TLC takes no exception to the circuits, ESP-65 and ESP-67, proposed by the Contractor. Please provide duplex receptacle with weatherproof cover at each location and a 20A/1 P GFCI circuit breaker for each circuit, connected with (2) #12, (1) #12 GND, in 3/4" conduit. Page 1 of 1 Ajax Building Company,LLC Project:202011 Monroe County FL Keys Marathon 109 Commerce Blvd Airport NAUB EOC Oldsmar, Florida 34677 7280 Overseas Highway ,AIM P:+18137923900 Marathon, Florida 33050 Email - Elevator Sump Pump Clarification #191 : Elevator Sump Pump Clarification Subject: FW: RFI #Con-191: Elevator Sump Pump Clarification Sent: Apr 12, 2023 01:51 PM EDT From Devon Ayers(K2M Design) To Denise Saltzman Cc Devon Ayers,Juan Perez, Mickey Pruitt Message Hello Denise, We received an email from Marshall stating: "Good Morning Team, Part of the RFI 191 question was requesting information on the power to the elevator alarms GFCI receptacles(Panel and circuit# needed).Can you please take a look at our subcontractor's recommendation below,and advise if that works?I have re-opened this RFI in Procore so an answer can be added regarding panel and circuit info. For dedicated circuits we recommend using two spaces,#65 and#67, Inside ESP emergency panel.—Pedro Falcon" Would you be able to assist on a response for this one? Thanks, Sent From Procore. Ajax Building Company, LLC Pagel of 1 Printed On:Apr 12,2023 01:56 PM EDT Vzago '°��' - a'vTi >�Lj - zQ 12 �O � Ow w o ¢ w i En 0 tE 5 e two �F se rpm I� �e m - m II � L V e �w c TR d s� iL � d pie w r h� mg = i g O M1- Z _a � ag y m� m 7 1 W W J .. ....°„ .. 0 q� IMM, xma poffisp S L ' } T I f 'r �"4 °arm RFI Response Con-191 RFI# Con-191 Reviewer: Giselle Albisu Project: 120825 - MONROE COUNTY EOC Received: 03/07/2023 Name: Elevator Sump Pump Clarification Returned: 04/09/2023 Please Note: The following RFI response is not intended to authorize any deviation or modification to the design documents except as specifically clarified below for this specific application and circumstance. Furthermore, this response is not intended to authorize any increase in construction cost, schedule or time extension, or construction in conflict with any applicable codes or specified design standards. It is the responsibility of the Contractor to notify the design team immediately of any perceived scope, schedule, or cost impacts or adjustments. Attachments 120825 RF1 Con-1 91 Elevator Sump Purno Clarification.Of Questions Attached is RFI Con-191 Elevator Sump Pump Clarification for your review. Comments TLC Responses: Refer to attached Plumbing pdf for the proposed location of the elevator sump pumps alarm/controls. Locations have been coordinated with the architect for approval. Elevator sump pumps selection (STANCOR) provided in the schedule on sheet P-001 are the selections to be installed. Page 1 of 1 ESP-1 , ESP-2 STANCOR LTNSLL STANCOR Oil-MinderO ����Simplex Duplex ....................................................... Pu",M a, ,,,n t,lrol Syste",M, s P ,n, d Co'' The Stancor Oil-Minder° Control and Solid State,NEMA 4x Pump System allows water to be au- Oil-Minder°Control tomatically pumped from elevator pits,transformer vaults, and indus- trial sumps without danger of ejecting potentially harmful oily sub- '' SE50 Pump stances into sewers, rivers and wa- with Float& terways. There is no need for a Oil-Minder° separate oil-water separator. The Probe product is engineered for efficient and trouble free pumping, even under the most severe conditions. The Stancor Oil-Mindee System is the overwhelming choice among design engineers and compliance authorities worldwide, and has a proven record for protecting valuable equipment and the environment. Fe a tU.:res • NEMA 4x weathertight corrosion resistant polycarbonate enclosures • Stainless steel sensor probe with patented electronic technology that repels dirt contamination • Single direct plug-in power source for operation of entire system • Solid state components • Alarms,lights,silence switch,and remote monitoring circuit for oil,high liquid,and high amperage conditions • Complete factory assembly and testing insures quality of entire pump and control system • Patented-Pat.#4,715,785,#4,752,188,#6,203,281 and others pending • Oil-Minden'System can be combined with a variety of different pumps and valves • Choice of: 115v or 220v(1 phase) OR 230v/460v/575v(3 phase) • LED indicator lights for oil spill,power,high liquid level,overload,and pump run • UL 508 and 778 approved • ENT+ELA tested and approved as a system a II l°here Is Only One 011 N .in14 e.r/ Sysh,)I1.1 i'Mid Slalnl.4w,or Makes H" Qtlahly I(1 a l l (,. a n Believe 1;1"11. ESP-1 , ESP-2 Description cor Sinipl :l i r"I Systems. The Stancor Simplex Oil-Minder°System is available in two primary configurations,as follows: The Multi-Option Oil-Minder@ System is designed for easy,fool-proof installation. All pump and control ca- bles are factory wired into a wall mountable junction box. Between the junction box and the main Oil-Minder° control panel is a multi-pin quick connect cable. This single cord,8-pin system allows the electrical cable be- tween the junction box and control panel to be run through conduit and interconnected up to 250 feet long, using a single"push and turn'motion. There is no need for field wiring. Electrical installation costs are re- duced by approximately 75% and all connections are secure and water-tight. The junior Oil-Minder@ System is a good choice where the main control is located in the same area as the pump pit,or where the main control will be located remotely and conventional"hard wiring"is used between a junction box and the main control. Comparative features of each model are as follows: Feature included in standard package O/M 0/M Multi-11 I'll I'll Option Junior SE-40(A HP)or SE-50(.5 HP)115V or 230V single phase pump x_ x Solid state NEMA 4x control panel x x Separate LED indicator lights on NEMA 4x control for A)oil alert,B)high water, C)high motor amps,D)power to system, and E)pump activation _ x x Self cleaning,hermetically sealed stainless steel oil detection probe x x Float switches for pump activation and high water alert x_ x Monitoring relays for alert conditions at remote locations x x High decibel,water tight horn and silence switch for alert conditions x x Direct plug-in activation of entire pump and control system from the main control panel (6' cord and molded plug included) x x Factory hard wiring of pump,oil probe, and floats into NEMA 4x junction box x Factory hard wiring of pump,oil probe, and floats directly into main NEMA 4x control panel x junction box with female 8-pin cable receptacle and disconnect x 25'8-pin Quick Connect cable(expandable to 250'with interconnecting extension cables) x Female 8-pin cable receptacle installed in the NEMA 4x control panel x 2 ESP-1 , ESP-2 m .......................................................................................................................................................... Selection ha Oil-Minder°Multi-Option Oil-Minder°Junior 1' o- 1s" j r 7 Power In RMS - RMS SE-40 16 ft. Paw Pump cables Power gFLOAT Mufti-Pin gi81. Flom 16.5" Connector i 25 ft.standard Pima a� (optional 25' Fmzt additional increments) With Selected Pump 9.1" 17" SE-50 Junction Ba' .... .... .... .... .... .... .... .... .... .... .... 40 16 ft. cables „ Pump Power 30 Pu Hg1, On L-1 Float Flea m -F� ��,�.,� .�..�..�. �..�..�...�..�..�. .�..�..�.. �..� ..�..�..�..�..�..�..�..�. .�..�..�..�..�..�.�..�..�...�. .�. oat 20 ....... ......... ............................... Probe N With Selected Pump 0 o 0 Flow-U.S.Gal./Min. 6(eu eu°�n& q Spe(ffii(aflons(Spe(i,fl V(lPag,es and p,mipuanaroalek avaflabne u,q)oGm ireapuues�p ........................................................................................................................................................................................................................................................................................................................................ Model H.P. Voltage RPM Rated Discharge Max Max Full-Load Size Head Flow Amps Ft. GPM SE50 0.5 115/230 3600 8/4 2" 37' 74 460 SE40 0.4 115 3600 5 2" 22' 64 STANCOR 3 ESP-1 , ESP-2 "I"ypical Stancor plex Multi-Option Oil-Minder7 m % 0 9 9 RMS POWER IN 8 PIN MALE CONNECTOR O MULTI-PIN CONNECTOR&CORD IN CONDUIT LENGTHSAS REQUIRED,25 FT.STANDARD, 25 FT INCREMENTS G PUMPPOWER GATE VALVE 6 COVER I - 5 7 2 8 0= 1. Stancor Model SE-50 submersible effluent pump.5 HP,115 volt,3600 RPM,2" discharge connection 2. Check valve(2") 3. Stancor Oil-Minder 115V,10 control system with built-in audible and visual alarm when pump does not run due to oil in pit or high liquid or high amperage condition. Provide silencing button for audible alarm built into panel. Panel shall have two contacts for a remote alarm location(one each for oil and high water or amperage alert). Junction box will be provided with multi-pin connector and cord in lengths as re- quired,25 ft.standard,optional 25 ft.increments. 4. Junction box will be provided with multi-pin connector and cord in lengths as required;25 ft.is standard, optional 25 ft.increments available up to 250 ft. 5. All buried pump pressure discharge piping shall be protected with tapecoat CT corrosion protection tape 6. Pump cable,probe cable,high liquid alarm cable,and pump"on"float cable(16 ft.lengths) 7. High liquid alarm float with clamp device to mount to pump discharge piping 8. Pump On float 9. Power cord and molded ground plug(6 ft.length) ITEMS 1,2,3,4,6,7,8 AND 9 PROVIDED BY STANCOR AS A STANDARD PACKAGE 4 *., �... Pauco I II. ESP-1 , ESP-2 `t:- ncx� (.)I`4(.X[-,1, ()t:y° I AVENGER SERIES SE-40 sznxc®�a Dwg: DS-A09-001 Rev: 2 Date: 01/16 MOTOR SPECIFICATIONS Motor Design Induction Motor Type Enclosed submersible Insulation Class Class E Motor Protection Bi-metallic Thermal Switch Bi-Metallic Temp Trip 120,C±5°C Service Factor 1.3 Voltage Tolerance ±10%from nominal MOTOR DATA,60Hz Output Full Locked NEMA Power Motor Pole/ Model Phase Power Volts Load Rotor Code Factor Efficiency Speed BHP Am s Am s Letter 100%Load 100%Load r m � 6 III 1 0.4 115 4.6 23.0 H 0.91 0.67 2/3450 1 0.4 230 2.3 11.5 H 0.90 0.64 2/3450 SE-40 3 0.4 230 1.4 7.0 H 0.91 0.66 2/3450 3 0.4 460 0.7 3.5 H 0.89 0.67 2/3450 3 0.4 575 0.6 3.0 J 0.90 0.65 2/3450 MATERIALS OF CONSTRUCTION Upper Motor Lid Nylon 66 Motor Housing AISI 304 Stainless Steel Oil Chamber FC-20 Cast Iron Volute FC-20 Cast Iron External Hardware AISI 304 Stainless Steel 0-Rings Nitrile(Buna N) Motor Shaft Stainless Steel(410) Upper Bearing Single row Sealed Lower Bearing(s) Single row Sealed Upper Shaft Seal CA/CE(carbon/ceramic) Lower Shaft Seal SIC/SIC(silicon carbide/silicon carbide) Impeller FC-20 Cast Iron DIMENSIONS,WEIGHT,AND MISC. Pump weight single phase 241bs(11 kg) Pump weight three phase 241bs(11 kg) Maximum submergence 30 feet(9m) Discharge size,standard 2 inch NPT female vertical Maximum temp.of pumped fluid 104°F 40°C CABLE SPECIFICATIONS MODEL PHASE/VOLTAGE POWER CABLE LENGTH OUTER JACKET 10-115V SJTOW 16/3 16 feet(5m) NBR 10-230V SJTOW 16/3 16 feet 5m NBR SE-40 30-230V STOW 16/4 16 feet(5m) NBR 30-460V STOW 16/4 16 feet 5m NBR 30-575V STOW 16/4 1 16 feet 5m NBR Power cable suitable for all standard voltages listed in"MOTOR DATA"section. Artuiro Oara m WASTEWATER 102 N 2rnd Street,Suite 51,0 SOLUTIONS 483 9(54) Ft.33 32. �954y 461269 arturo@ww's-1Ic,c0m Specifications subject to change without notice Stancor,Inc.515 Fan Hill Road,Monroe,CT 06468 Tel: 203-268-7513 Fax:203-268-7958 www.stancorpumps.com *.,OAS �... Fla c (r '1 12 ESP-1 , ESP-2 AVENGER SERIES SE-40 srnxcoa Wg: IDS-A09-003 Rev: 2 Date: 03/16 SE-40 Horsep")Wer: 0-3 111, Stan cor Model SE-4 0: I Iertz: 60 1 1z Individual PerfmnanceCurve 30 100 too 25' 80 0.80 ILL 201 HQ 60 0.60 15 40 0.4�O 000 io, BHP 00 20 0.2110 5' LEFF 01 0 0.00 0 20 40 60 so "Wro 102 NE 2nd Street,Suite 510 WASTEWATER oca Raton FL 3343,2 �Z'SOLUTMNS LLC (B,04y 483 9,269 ar4Aro@Ww5-IIr'cOm Specifications subject to change without notice Stancor,Inc.515 Fan Hill Road,Monroe,CT 06468 Tel: 203-268-7513 Fax 203-268-7958 www.stancorpumps.com �Be o ks ESP-1 , ESP-2 `t:- nc;rrir (.)I`4(.X[-,1, () y: I AVENGER SERIES SE-40 sTnxc®�a Dwg: DS A09 004 Rev: 1 Date: 05/15 SE-40 o � "'�x'� _ ti cw Type I DISCHARGE I A I Al I A2 I B 1 131 1 B2 I C I C1 I C2 IC3 INCHES 2" 5.71" 1 2.60" 1 3.07" 1 5.20" 1 2.83" 1 9.09" 1 15.59" 1 10.47" 1 4.33" A�d girl.fK'i WASTEWATER 102 IN F 2nd Stlaeef,su�fe 51 Boca Raton FIL 33A32 SOLUTIONS LLC (954p 483 9269 arhnrota wxs.uur,corn Specifications subject to change without notice Stancor,Inc.515 Fan Hill Road,Monroe,CT 06468 Tel: 203-268-7513 Fax:203-268-7958 www.stancorpumps.com UK ago .rJ / W a a>a O �W >zLj0 0 Z O cn d .i a wOaU a CFI cz pose o 0 U � �m � 0 3 ✓F` 1 (� t I �s� n. "M w� K FJ ;l '!J r a w w a Y nm= oa � H s o 9 'S" m i3 sm m� o3mi3 �a mad z- �� Eg �wK =o _ "a om_ MM fig MH N. M. 0®K 0 VK'°��' ✓v Ci�19. - o W II a r cn ri.l 0 Y - �v'J��O zg�w dz a W 8 w o 0 :5 a a v } PR LLI W op �� F N�P Q W =y X CL W gg w cn = r a � �--- o° ws wssssssg� Z Y a o s Lu gp aHh a o d o d � w z ,x d a�= N Opiiiip�pp tg- - W III� a W r a W a s cn 0 0 W U H J� W Zz �z M f0 ig 'a 111 I = ya: pdo ' gos — O 14 �tlb✓ QLJ W H cn � II II X w .r— w _ H s J m� W d \\ 2 $ O W d � Ws s m s cn _ ,.- w z z m z m z Trusted.Tested.Tough.T"" SECTION:2.35.050 p OEL FM00716 Product information resented here reflects conditions at time of publication.Consult factory ZSupersedes regarding discrepancies or PUMP COMPANY 0516 inconsistencies. TECHNICAL DATA SHEET �jalrdSYSTEM For Submersible Dewatering Applications Designed to help protect the environment and equipment from the dispersion of oils and/or hydrocarbons. SYSTEMS: • Operation of the Zoeller"" Oil Guard° System has been independently verified by OnSpeX, a division of CSA, when installed in accordance with our instructions. • Choose from four pump models. Includes pump,Oil Smart°switch and alarm(optional control panel) • Controls are ASME A17.1 compliant Oil Smart"SWITCHAND ALARM PANEL FEATURES: • NEMA-4X alarm panel enclosure • Audible,light alarms and dry contacts • Preset"on"and"off"points differentiate oil and water and alerts maintenance personnel of high water or oil detected conditions • 20'(6 m)piggyback electrical supply cord " • 20 amp internal relay • Alarm test and silence switches • 304 stainless steel probes • UL508 approved switch PUMP FEATURES: • Pumps are durable,cast iron construction with powder coated epoxy finish and all stainless steel fittings. Product may not be exactly as • Tested to UL Standard UL778 and Certified to CSA Standard CSA 22.2 No. 108 shown. PUMP PERFORMANCE CURVE F MODELS 57/152/153/161 TOTAL DYNAMIC HEAD FLOW PER MINUTE � , MODEL 57 152 153 161 Feet Meters Gal. Liters Gal. Liters Gal. Liters Gal. Liters 5 1.5 43 163 69 261 77 291 100 379 10 3.0 34 129 61 231 70 265 93 352 15 4.6 19 72 53 201 61 231 85 322 20 6.1 -- -- 44 167 52 197 79 299 25 76 34 129 42 159 70 265 30 9.1 23 87 33 125 62 235 35 10.7 -- -- 22 83 54 204 40 12.2 11 42 45 170 ,o 20 o ao .o Eo ,o ao so ,00 „o 50 15.2 20 76 R�o,�R Shut-off Head: 19.25ft(5.9 m) 38ft(11.6 m) 44ft(13.4 m) 56ft(17 m) ���� �� �� 1. �� F 16 010 PER1°11°'E ��� ��� 1 41018939 018939 /-,vD 9' A WARNING These systems are not designed for T�GH hazardous environments.Please consult factory for special cD t`�o options and requirements. ©Copyright 2016 Zoeller°Co.All rights reserved. 502-778-2731 1 800-928-7867 1 3649 Cane Run Road I Louisville,KY 40211-1961 1 www.zoeller.com MODEL 57 MODEL 1521153 MODEL 161 6-7/32" 83/4" 3-7B" 6-3/16" 1158 mm1 [98­1 [157 mm] 3-7/8"(98 4-5B" mmJ 4-5/8" (101 mm 6--1/1/2" 2 mm) 1117 I (165 mm)� 117 mm[ m m 3-7/8"(98 m m 3-7/8"[98 mm] ® 4" 01 MM) 1 4 0 © 3-7/8"198 m m 3-7/8"[98 mm] 1-1/2"NIT 1-1/2"NIT 1 1/2"NIT 2"NIT OR 3"NIT AVAILABLE 12-1/8"1308 mm J _ � I 10-1/16"[256 mm] L�pl� I 9, - 5 — "1137 mml 18-9/16"(471 mm 3-3/32"[79 mm] I 6"(152 mm) SK1015 SK2064 SK2644 See FM2778(model 57),FM2784(model 152,153),FM2785(model 161)for complete pump specifications. CHOOSEA PREPACKAGED SYSTEM Part Alarm Oil Smart° Nonautomatic Pump Elevator Number Description Panel Pump Pump Part Number Volts HP Amps System Switch 940-0005 Oil Guard®Pump Switch and Panel 10-1526 10-1528 N57 57-0002 115 3/10 9.7 N 940-0006 Oil Guard®Pump Switch and Panel 10-1526 10-1528 N152 152-0002 115 4/10 8.5 N 940-0007 Oil Guard®Pump Switch and Panel 10-1526 10-1528 N153 153-0002 115 1/2 10.5 N 940-0008 Oil Guard®Pump Switch and Panel 10-1526 10-1528 N161 161-0002 115 1/2 15.0 N 940-0012 Oil Guard®Pump Switch and Panel 10-1526 10-1528 *N152 *152-0028 115 4/10 8.5 Y 940-0013 Oil Guard®Pump Switch and Panel 10-1526 10-1528 *N153 *153-0027 115 1/2 10.5 Y 940-0014 1 Oil Guard®Pump Switch and Panel 10-1526 10-1528 *N161 *161-0090 1 115 1/2 1 15.0 Y *6'(1.8 m)SO jacketed cord for oil resistance. OR BUILD YOUR OWN SYSTEM Oil Smart° Oil Smart° Oil Smart° Part Description Alarm Pump High Liquid High Liquid ACAUTION Number Panel Switch Alarm Switch Switch All installation of controls, protection devices and wiring 10-1526 Oil Smart"Alarm Panel should be done by a qualified 10-1528 Oil Smart®Pump Switch --- --- --- licensed electrician. All electrical and safety codes should be 10-1727 Oil Smart®Pump Switch w/o Plug --- --- --- followed including the most recent National Electrical Code (NEC) 10-2149 Oil Smart®Simplex Panel --- and the Occupational Safety and Health Act(OSHA). 10-2150 Oil Smart®Duplex Panel J J J J 10-2516 Oil Smart®Simplex Panel w/Mtr. J J J INCLUDED *VARIABLE LEVEL FLOAT SWITCH SIMPLEX PANEL: DUPLEXALTERNATING PANEL: • 115V,single phase . 115V,single phase ej • NEMA 4X watertight enclosure w/lockable latch NEMA 4X watertight enclosure w/lockable • 30 amp motor start relay / latch • Pump HOA switch , • (2)30 amp motor start relays • Top-mounted red alarm beacon light �% • Pump HOA switches • 81-84 decibel rated alarm horn ''� • Top-mounted red alarm beacon light • Horn silence and alarm test switches • 81-84 decibel rated alarm horn • Alarm automatically resets ° %� - • Horn silence and alarm test switches • Dry auxiliary alarm contacts • Alarm automatically resets • Separate circuit protection for alarm • Dry auxiliary alarm contacts • Circuit breaker protection • Separate circuit protection for alarm • Pump"Run"indicator light Model 10-2149 • Pump"Run"indicator light Model 10-2150 ©Copyright 2016 Zoeller°Co.All rights reserved. 502-778-2731 1 800-928-7867 1 3649 Cane Run Road I Louisville,KY 40211-1961 1 www.zoeller.com OIL SMART PUMP SWITCH Application The Oil Smarto Switch is factory-calibrated and set up for immediate installation and operation. The dielectric design is extremely Dielectric Data Chart sensitive to variations in dielectric constant of air,water,oil and/or 00.0 80.4* hydrocarbons(see Dielectric Data Chart). Material 70.0 - - - - - - - - - - - - - - - • The Oil Smarto Switch is constructed of high-impact, injection- molded plastic. R = Enclosure(Ignition-Proof). 50.0 — — — — — — — — — — — — — — — • � • 304 stainless steel sensor probes. 40.0 — — — — — — — — — — — — — — — d d 0 Temperature 30.0 - - - - - - - - - - - - - - - • The Oil SmartO Switch standard temperature operation range is 20.0 — — — — — — — — — — — — — — - -33°F(-36°C)to 170°F(77°C). 2.1* 2.2* 1.0* Operating Pressure 0.0 • The Oil SmartO Switch is designed to operate to 30 psig (2 bar) water Petroleum oil Transformer oil Air @ 68°F @ 68°F @ 68°F @ 68°F at 70°F(21°C). 120°cl 120°cl 120°cl 120°cl Standby Current *Note: Estimated values. • 0.004 Amps. Signal Output The Oil SmartO Switch is configured at the Factory. • 120 VAC-50/60 Hz(6 Amps). Relay Configuration • 20 Amp internal relay. Approval • UL Marine Listed • CE Certified Control Circuit • Solid State. Power Input a a • 120 VAC-50/60 Hz. ON OFF SK2404 ©Copyright 2016 Zoeller°Co.All rights reserved. 502-778-2731 800-928-7867 1 3649 Cane Run Road I Louisville,KY 40211-1961 www.zoeller.com Oil GUARD° PUMP SYSTEM Single Phase Pumps 2. The Oil SmartO Pump Switch is an industrial grade switch with General internal 20 amp relay and 304 stainless steel sensor probes 1. Pump motor shall be hermetically sealed, submersible-type used to control water pumps in elevator, utility, marine and operating in a high-quality dielectric oil for cooling the windings industrial sump applications. Installation will prevent oil and and for lubrication of the motor bearings and ceramic-carbon or hydrocarbons from being inadvertently pumped into the shaft seal. Single phase motor shall have internal automatic environment. resetting,thermal overload protection. Construction shall be of Options: cast iron with 100% baked-on, powder coated epoxy finish for 20'(6 m)cord with piggyback plug. corrosion-resistance and longer casting durability.All fasteners and external metal parts shall be of stainless steel. Impeller 3. 115 Volt Piggyback Power Plug shall be of vortex non-clog design. Check applicable series. 4. Oil SmartO Alarm will alert residents or maintenance personnel 57(0.3 HP)cast iron series pump shall have a shaded pole of liquid level problems. High Oil and High Water Level Lights motor. Guard and handle shall be stainless steel. and standard Remote Dry Contacts(SCADA Monitoring System). 152(0.4 HP) 153(0.5 HP)series pump shall have a Alarm System with High Liquid Audible Alarm (71db @ permanent split capacitor motor. Motor housing shall be cast 2' [0.6 m]), Red Beacon, Oil Present - Yellow Light and Water iron. The impeller shall be glass reinforced thermoplastic. Present-White Light. Built with Oil SmartO technology. 161 (0.5 HP) series pump shall have a 3450 RPM motor. 5. Liquid Smart Sensor' incorporates both an electro-optic and Motor housing, switch case and pump housing shall be cast Oil Smarto Sensor all in one encapsulated unit. Differentiates iron.The impeller shall be bronze. and indicates the presence of oil and or water under high water condition. 6. Check Valve Recommended(purchased separately). 0' ` 7. Optional Oil Smarto Simplex Control Panel - Built with Oil 3 � ° SmartO technology. Will control pump and alert residents or i ®- OR maintenance personnel of liquid level problems. High Oil and SIMPLEX High Water Level Lights and standard Remote Dry Contacts (SCADA Monitoring System). OR Simplex Panel 10-2149. 8. Optional Oil SmartO Duplex Control Panel - Built with Oil 5 2 Smart@ technology. Will control pumps and alert residents or DUPLEX maintenance personnel of liquid level problems. High Oil and High Water Level Lights and standard Remote Dry Contacts $ (SCADA Monitoring System). ° Duplex Panel 10-2150. Notes: 20 Amp Relay is inside pump switch. SK2423 For float tree installation see FM2364. ©Copyright 2016 Zoeller°Co.All rights reserved. 502-778-2731 800-928-7867 1 3649 Cane Run Road I Louisville,KY 40211-1961 1 www.zoeller.com Trusted. Tested. Tough.T" SECTION: 2.35.060 p ff ® FM2675 1211 Productinformation resentedhere reflects conditions attimeof publication.Consultfactory Supersedes regarding discrepancies or PUMP COM 0811 inconsistencies. MAILTO: P.O. BOX 16347•Louisville, KY 40256-0347 SHIPTO: 3649 Cane Run Road •Louisville,KY 40211-1961 Visit our web site: TEL:(502)778-2731 •1 (800)928-PUMP•FAX:(502)774-3624 zoellerpumps.com Oil Smart System Kit Applications: The Zoeller Oil Smart°System Kit,when combined with • Elevator sumps a manual sump pump, will automatically pump water • Transformer containment areas without the risk of pumping oil into the environment. • Underground vaults The panel provides complete pump protection and • Areas where water removal below a layer of oil/ hydrocarbons is required monitoring.Additionally,the system alerts maintenance Models: or building personnel in the event of a high oil or high UL Listed and CSA Certified water condition.The control panel comes complete with • P/N 10-3163- 120/208/240 VAC Single Phase,operates all required controls and panel monitoring capabilities. pumps up to 1 HP @ 120V,2 HP @ 208/240V Installation of the Simplex Panel allows you to comply Also available:Consult Factory with State and Federal regulations while reducing the risk UL Listed for the US and Canada(panel and controls)• of adverse publicity, fines and expensive cleanup costs. • 208/240 VACThree Phase,operates pumps up to 3 HP @ 208/240V • 480 VACThree Phase,operates pumps up to 7.5 HP @ 480V, includes main disconnect • 575 VACThree Phase,operates pumps up to 7.5 HP @ 575V, includes main disconnect Kit Includes: 0 0 • Simplex Control Panel o o O • Oil Smart@ Pump Switch • Alarm Panel • Liquid Smart@ Switch 10'power cord Features: 100'cord to remote panel • Pump control and high liquid alarm differentiate between oil and water. Includes Oil Smart@ pump control and Liquid Smart@ alarm switch. 10' cords included. Pump Control Features: • Pump Hand-Off-Auto (H.O.A.)switch,green pump run light and power on light • Remote monitoring dry contacts: oil,water,high liquid • Pump protection: Pump circuit breaker Alarm Features: • Remote alarm panel equipped with yellow light for oil, white light for water,alarm test and silence buttons,85 decibel alarm,and high red beacon alarm light. 100' cord included to wire to main control panel. Includes dry contacts: oil,water,high liquid Technical Specifications: • Panel enclosure: Opaque front heavy duty NEMA 4X polycarbonate, 10"x 8" x 4"with lockable latches • Switches:Type 3R high impact injected plastic • Oil Smart"switch dimensions: 2.5"w x 6" h x 1.75" d plus 6" sensor *Pump sold separately SK2891 • Liquid Smart switch dimensions: 3.5" h x 1.5"w x 1.5" d • Remote panel enclosure: NEMA 4X,6"x 5" x 2.5" @ Copyright 2011 Zoeller Co.All rights reserved. av s N N O O O O N N N N N N N N N N N y N N N N ry ry N N N N N N N N N N N N N N N N N N N N N N N N N N > O N 1 1 1 1 N N N N N N N N N N N y N N N N ry ry N N N N N N N N N N N N N N N N N N N N N N N N N N p• m N N N N N N O N N N N N W\V\V n m m m m m N N m N N N N m m N N N N N M M M M O. N N N N N N N N rl rl rl rl txo a N N N N N M M M M M M M M M m m m M M M M M M M M M M M M M M M M M M M M M M M M M m m m m N N N N N N N N O N N N N N N N N N N N N N N N N N N ry ry N N N N N N N N N N N N N N N N N N N N N N N N C �+ O O O O ry 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 @ N N N N .�N N N N N N N N N N N N N N N N N N ry ry N N N N N N N N N N N N N N N N N N N N N N N N V 0 1 1 1 1\rl rl N rl rl rl rl rl rl 1 1 1 N N M M N N\\rl rl rl rl rl rl rl M 1 1 1 1 1 N N N 1 1 1 1 1`� rl rl C tx tlo p ++ u 8 C = v m m ui j � m O i Q V » 0 4 F `b', ouoioom � o 0o p o0 04000 `a' `a', o `a' `a' `a', uoi, o `a' `a' `a', W p M ui O st M n N O 'i �} ..i O 00 n ui of N O O ��}} N M N O �+f O N N ��}} 01 ci n O pp m of M .-� �G O .-� n W O m W m n > oD N n W n W .-� M .-� �} O �G O st st .-� M �G O ��}} ��}} of W st .-� of N 00 of T W V Q of O O St M O �G �G n W N of Ct of M O M n St n OO M a0 .-� O M 00 St oD M n .-� N O N N 00 �7 .-� O O n M W St of m m m �p N N�p of O 1,z Ve of rl rl W�G rl 06 rl V�rl M rl n O M 06 rl M M V�rl V of W rl n � `•'rl `•'rl rl N rl 1p ....� rl rl � � ....�N��...�...M..� rl n `•'`•'rl rl rl `�'rl rl rl `"rl `�'rl `�' ` W � 5 LL — v LIJ W J O' CO a O N Z co g °a o O w W ° U C. ao Z O N Q } `O Z ° p W `o Q ui y^ W ° }yL E M M Z r M 0 Lu Z N `O rl ryj V F Z O Z O ° a `^ y a ¢ ti 0 0 O 3 ° V Z > x N �, N u = y = 0 v m y c �nl o x ° al Q N EO O d C N p z ¢ E a Q J t m o ' c E c x o N N O�J u MI C E C = N N O ° `p N .ti >'p M N al N D aJ N G fO N w C ♦+ m Q aJ in E O Q' ti0 c E in MI Y L N O c ^ i OI aJ lOp C N V a O�J a C Vf N °. u O u 0 u aJ N c '�' Q 0 LL N V y o u _ = v .ry-7 f0 m c - y c� a=i rri m M E '" o• 0 c c 3 E O c °' v .-� _ as ,°, o c as m t ^! . _ ^ v m = •�, m p_d O V 'm c m 4 2 0 3 c v ti -°° u c 3 '°J^ N E O .t u a o r O en c ,—°� .+ M Q E m o 0 N � v O }`y c 0a V t u m ° ° ° o O as a c y`O_ as Q �°, _ — 0 as a ° d m u E y v N a o OA u V u c ''� C p _ O tO O E O0 y_ o u t o al E aJ a E c o'J •- E c c o u m m" c m '^ m 3 a+ N a = v o E m° s v w 4 m v o MI•o s o «' �' °J •o N co �y,' m'^)�,-.'iG°c°v3C°cs uv3co3c iN 0oaOo°��3s- cSc vLtcof0 .o-?� oC"'J •p�3c+ v.m3acs `'m�m=c=pu°O> pca3>s -macins _rymvm,�c t0.*`a's Y.m�m Q° •�cN�' "vaOvaJ .�c�E� mu umCaaOss s=c>d 0>o' a0amJs pNm-m o`u`.°°+ pp"ry,;�' Y°°' p0O`oO° mm�aE's y•.,�-,i� 'muaa3�s a—rv. -FWy WQccOovv+0=wacam's Vmo x•�c°m�J »•c3e- -a'mo $ o m N W$0v 6 *- m o . mow0v O mr O c : EO O E : o o co m a o ° M 3ucOv0,°` LL=Qz4oayN"O O O au= a ° a v o u „° o v a . cv cuo a o o xK o o o a u a° W c , 'E cc = ° O " o> o 60 E a O e > aA M Mti NE D voa°o'JPE 'o ° ° o aO O ryiN0 o • o o o > > 0 o° Y N ` ryE NE . o o o v > > �° N W cm ^ O 0 0 0 0 I O � O`• I w I I I I I I I I °" C la'1 N eM•1 N V�1 3 0 .M-1 .•+ V�1 eN•1 .�-� n «� M . . N m m w m m o o m w o n w m � n � o eM•1 N M e0.1 .�-1 N O N N N .O-1 u •C � ei ei ei ei V ei O ei ei ei ei ei =o ei ei ei ei ei ei Ill ei ei ei N N ei ei ei ei ei ei E ei E N N N N N N N V N N N Il1 N O _ _ _ ^ _ _ p V Q = = = = - V O Q = = = = = V 1 . 1 1 1 1 N 1' 1' 1' 1' 1' 1 1 N 1 1 1 V 1 V 1 1 1 1 1 1 1 i 1 1 1 i .. N M V . . 00 m O ei N M V Vf �D i� W m O ei N M V Vf �D i� W m O ei N M V Vf �D i� W ei ei ei ei ei ei ei ei ei ei N N N N N N N N N N M M M M M M M M M M V V V V V V V V V V O V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V �{ z ON ON 0 0 0 00 O O eO O ei Om 0 00 eO . eM eO eO . eM eO . . . . . e00 e00 . . . M M W O W �D m O O ei O O O N N O ei ei ei ei ei N ei ei ei N N N N N N N N N N N ry F O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O \ Q V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V \ a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a M N M M M M M M N N N M M M M M N N N N N N N N N N N N N N N N N N N N N N N N St St '7 N N N N N N N N N O N N N N N N O O O N N N N N O O O O O O O O O O O O O O O O O O O O O O O O N N N O O O O O O O O O N N N N N N N N N N N N N N N 1 N N N 1 1 1 1 1 1 1 1 1 N 1 1 1 1 1 1 1 1 1 1 N N N N N N N N N N N N . . . . . N N rl rl rl m m m N N N N N rl N N N --------- N rI rI rI rI rI rI rI N N N .-� .-� .-� rl rl rl rl rl N N N N rl rl rl rl rl rl rl rl rl rl rl rl rl rl rl rl rl rl rl rl N M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M N N N N N M M N N N N N N N M N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N rt N N N N N N O O O O O O N N O O O O O O O N O O O O O O O O O O O O O O O O O O O O O O O O O ON O O O O O N O O O O O O N N N N N N O O N N N N N N N O N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N O N N N N N N N N N N N N N N h h h h h h W W W W W W W m m m m N N N N N N N N N N N N N N N N N N rl N rl rl rl rl rl N N N N N N N —— —————— ——— p— p� p� p� p� p�� p�p p�p p�p p�p p�p � p�p p�p p�p p�p —p —p —p ——p —p —p —p —p p—p ———————p ——p —p —pp O O O O O O O O O C. O O O O O O O O OV O O O O O N O O O O O n O 0 0 N 0 0 0 0 0 0 .O-� O O O O O ONO O 'MR 0 0 0 st 00 .-i O ��}} O ui n O ��}} �+f n oD N .-i w of .-i N M of w 4 �} N .-i pp n O O N tYl N M of .-� of st p O m �G �G O O N n a0 n �G O N p M M mp N St M N M w OO w N h N rl N �!f m h OO St w O rl h m m O M ��}} �!f W h m O M W N m h N m N m St N � St 8 m rl St h m O m M N h M O m N Lff �G N Ct N N rl M L/1 m OD N St m m O m �p rl St �G N h M O m O h �G V� rl .... rl N rl n m V of M of �/1 W m M rl W N rl rl q M V M N rl h rl M V rl V .... W V V rl V rl rl rl n rl rl N N rl M 1!1 N St .... ............ .... .... ........ ................ .... .... .... ........................................ ............ .... ............ .... rl N C o 0 m N f0 O c °• as ° m E u o °I w E ° ry N c o u w c ry O O C O O in C o O C C w O C O C O o 'O tYi. N ¢ ) N o v `" 3 as �' -° o ° :° ° ° '' N o = ei G 3 u LJ N ♦+ N w N 't+ i� :t o y o c Q Q °- o °o. o c as y axi M o E E K x M x o -°o o OJ N a m O u O in N eryi d N N ry O C w °' E OO N yOj N m M f0 •m c Jv Y 3 O o Y as [: ei y ry ° ^O mm > C O O N N yl N L ei Ou a+ \ ¢ C N M O p m = O N O OO E in C F _ N O- N C = mm V O Y O N \ O N O ry V u ^ c .ti E '^ — — u c 3 as 'y '^ J c '�+' 3 ° '�+' .•� �, c en v ° -° > OIL aQ O ry d '^ •� m *' $ c o l7 0. -°° d c u o u. 3 p u. a N c .-� c y .-� a E v c .f0.� ..� c •� 3 v o C N _ N O. N N - N N -m N N -O w O ry O .+ v t ra '^ > ¢ '^ t .+ > ^� o: 3 o m as > as y m c c m a N ° C O o V N ¢ 6 d ry M 3 = V C O J mm "O N C ry pm J O N u ry ° u Q C - C `J C C C E v o .-°i E a v o:l $o �, °- s $o ._ o •-� N ° ° f0 > u ° m o o -O ..� > v ,m., E o LL ry ° m .-� " v M N m 3 O'J y '^ •� $ 'C em �, as O o m E .ti ° ..� „°„ '+ 3 v� a c ° � .-� a`+ c E „ v� o ° O'J — `y u o > v as `� N }`o O ° O aal a o° x o E c en x°' a°i •+ u `t �' ry O'J is n o v °- F V '.' u '° .-� m as V ? •3 ° a .o V — o: o „v, m �`o� o as 'G c y a M a a✓ 3 ry ,� w o o o: m -u o- o ,� V `� 'T+ v� o as - ._ m A � � �o ry m � .°.� � .o C p_ l� O E C N =� G C v�i C 3 M ry N N ei m2J mom d O N N u N _ ° Y N C u a Y C m o c m o v .-� v `o ry _�, 3 of c c as � o « o � c v w y a c as c `o m as m o m as c m = � vv a 17 m V ° a .-� > o - �o u v E o E ra `oo y V y O o c E o v v� ra as N ry L oo as y a` 'G o o u N m -° o •E o •� `° ry ° °- E c t c c -° y _ V m E E ° v �+ \ — en — as x o 'C x c .o o: a o E m r� E v_ m m t > c ° 3 c ° o a o m -° N w m '� ;+ v as o . o "° ¢ �+ m w o as E en v $ o 0 o V y v '� c u a m O o �a G m ° 3 m �o c -° a Q ° c v o % c as m 3 o a c v o °' ..� o t c '" v� .°. ry c 17 °' "° o y E m o LL = u ° 3 V o c v� `m E 'o o �' `o m m O c o: v o: E as o J ° 3 > as x > a as �`°o as v em u .°� v a°i i0„ '- as i:+ .°� v ° E �+ u > ° as c c ° .°.� m as o v' m > m � v ° m ..� m 3 c ._ o ¢ V as m y ° a .-� a o .°. o m e _° o u u m ry m c ° "" y `° o c O cam°, '° y as > y 'u. �O m V `° a v ° °°, Jt y ° E rig °' s p � w' �' .0 `° '^ m $ m = c E N v v c c '° a f0 y`O_ ` m o °- m .°.� - m um. -° a "' u u v°i v E E '^ ° o o V � � a u m �, '3 °o E - v as - m a E c E a v°i v' „aa, u ,_ n 3 u as j 4 0 '> }`O �ri m n am �n �n o v > > r m o: o m v� Yam°- x c = > ° . `oy ° - x ° c a as O ry d as .-� �o M ry . ¢ r ¢ rm c o c '� ° .f0.� L, m °- o: v �w d f0 m y 'G o c\ v °q o -° 2 O t` ) N C Vf C N N N N OO "O OO OO "O O O N G O ~ O y 6 = u 3 ~ N O ° •..� E F o M v E c c c c v as •,,, ,°, E c as c 'en aso m c a c v E E E E o- 'Z7, 3 y i:+ w ry A -o ° a+ v v a F c m a v O c E �o E ,..� „v. L 3 0 0 0 0 ° ° vv w v o `0 17 v v v� v °• o V ry 3 ° en o v o — v vv yv 'c m .-� v v c '° m o V ° v v as as v o: o o o o o v v v v t v m c v ° *' as o- — v Q o:l l7 0: w m OI ¢ O •-� a o: o: o: o: o:l c Q w w N o a N m N w o N M o N N m m N N N N N ei E N N N ei N N N N N N N y N N N � N N N N N N N 0 = V1 C N N N N N N N N = N C M E N M N N M M V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V N N ei N N ei N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N M N M M M M N M M N M M M N M N M O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a 3 3 3 3 3 a v 3 v 3 3 v 3 3 v 3 U E O o '¢' o '¢' '¢' o '¢' '¢' o u° Mo N N N N M M VI N N O O O O O O O O O O m N N N N N N N N N N 10 1 1 1 1 1 1 1 1 1 1 1 1 t 1 1 1 1 1 1 1 1 1 1 1 1 V C N N M co co co co 8 S 9 n st O i r r r r O O u0f ~ n N V v ro A o N umi N c o m v v v n n n ri ri ri � ri ri ri ni ui ac ui � ri St M N OO m N �!f St 1� OO � W rl N N N N N y�N N N N N N N 1A Y W � z � z z z l7 ¢ Q � V O w V V 2 � w 2 � o 2 z F V � 2 O Q V F � 2 F � V a O a o0 v m a N N N O ` N O = O pl C o c a ap o — •" LO O. V\f ry m N O E o C C _ N yo. m V N C d u 0 « O N O C d � vpi t N C O m "p ut V O u E ra L o u f0 " o m Q c m v 'm^ o E o N v m 6 oo � m m o t o vi m y c E c E y m m 3 v v o " °- o N u o o °- ° 2 c p° —oc °- v o V Y`o_ c c Q axi t v o >• '^ N v y m V „o, 3 2 o v u m u c m m y m o en v o w o m a d 3 m m m e v ami c — a u a+ c = m m u o d u m v = v o v a c ° E ° o m mua "'' °' y ¢ a v o °' v E F .� o. '"' m v L v m o u> N N O. ymj N O w Y N O m •u Oq C y m K m u 0 vOi emi O O. d Q m N O C O OJ m m N O' `J 0 0 a. o m y 0 .° p m 3 o m c E v ~ y c ¢ v v o o m o E m Y y m y c m o o ¢ o x y a�i y l7 vti v ° cti �° 3 uo. •_ "' O iz v M N N M M o — V N ei ei u N N O N u M u M M C ti ti ti ti ti ti ti ti ti ti ti ti V V V V V V V V V V V V L V V V V V V V V V V V V V V V V V V V V V V V V m m O1 N V M ei M �D V O �D V1 00 V1 V1 i� W O1 V1 i� O W M N N M M M M M M M ei M 2 N N N M M M M M M M M O O O O O O O O O O O O F cc cc cc cc cc O V V V V V V V V V V V V ¢ V V V V V V V V V V V a a a a a a a a a a a a a a a a a a a a a a a 0 mw yj E E u° ° ° u° u u � � u � o _ _ E 0 0 :o Z Z Z N N N C 1 11 N Q ' N m N N N N N N pO N 14 O O O O N m COC ti V 1 11 N O Y a V N N V M O 111 W N i C N Vh rl 1!1 1!1 rl F Q @ p V pp pp pp pp Q 3 M ° ° R $ q � ti O m O M Q N N t'ON1 N O R i *' a w v o ho R N N N C N N e�•1 c s v p H H H H H M H H H H » 2 O O V y w Oq r C 2 v � c V V 2 3 m V 2 3 0 a c v � v o Oq u V � C O C 00 C y O L N_ � N C > > C —y 3 N O pOq m 0 O Nh a Y # C N Q O y � 0 XN N O u C �L C ' O C E x 0 u s v E l�'J w F w 0 m m v o as o cc 0 en co co m m m O Q O O O O as .N•iwmwo 2 N Q O cc cc V V V V V a a a a a OWNER CONTROLLED CONTINGENCY LEDGER FL KEYS MARATHON AIRPORT NON-AERONAUTICAL USE BUILDING (EOC) Initial Contingency Amount: $955,613.00 Total Debits Total Credits Total Adjustments to Date: ( 576,1.77.77) $483,683.65 ( 1 k1159,86x1..42) $ - Current Contingency Balance: $379,435.23 *EO designates PCA as an Error or Omission on Designer ur, s ut f Initial Budget 0.00 € 0.00% € $955,613.00 This is a cost change to the Project Contingency to add a GPR survey of the site prior to underground utilities installation beginning in order to locate potential unknown utilities that are not shown on the contract documents. Contract time is not impacted. 10/05/22 (1,1rD11 11&1) € -0.68% $949,113.00 This is a credit change to Contingency for all work related to RFI 121,dated 10/12/2022,to document the email correspondence with Cardno that the injection well casing is only required to be 60'deep, not 120'deep per C-008. The total depth drilled will remain 120' but the casing is only required for 60'.Also,the material of the casing is acceptable to change to Schedule 80 PVC in lieu of DIP (ductile iron pipe). 12/08/22 12,000.00 1.26% $961,113.00 This is a cost change to Contingency for RFI 113,dated' 09/21/2022,to add window shades at the exterior windows in room 235 and 262 that were not previously calling for shades. Reference sketch included in RFI response, 1111.00 12/08/22 (2,093,51) -0.22% $959,019.50 This is a credit change to Contingency for RFI 124,dated € 10/06/2022 to document the variance between ID-202 and A-131 on the mirror manufacturer and the decision to go with the Bobrick B-165 series mirrors due to the cost savings to the Owner over the Renwil,vered mirrors. Id 12/08/22 16,455.00 € 1.72% $975,474.50 This is a credit change to the Contingency per RFI 151, ated 12/08/2022,for the Owner request to change all countertops in Food Prep room 260 from Quartz to Stainless Steel. 12/16/22 5,330.00 0.56% $980,$04.50 This is a cost change to the Contingency to fund the FKEC fee worksheet for the electrical primary service. 01/10/23 (10,01432) 1.05% $970,790.18 This is a cost change to the Contingency to fund the City of Marathon Utilities Force Main worksheet fees.; 11,1414 01/10/23 (27,663 63) € -2.89%€ $943,126.55 OWNER CONTROLLED CONTINGENCY LEDGER This is a credit change to the Contingency for changes from submittal 084113-1,dated 12/01/2022,to change the 1203 window from an insulgard ballistic window to a standard YKK interior storefront window,and to change door 218 from a double door to a single door with a sidelite due to a conflict between the corridor width and the required width for an insulgard double door. 01/23/23 14,607.00 1 1.53% $957,733.55 WIN HI This is a cost change to the Contingency for ASI 01,dated 11/28/2022,for; -The changes to the primary electrical routing and equipment for the building's power per FKEC requirements,and -The addition of the quick-connect equipment to add the s ability to connect a portable load bank.' 02/14/23 (65,712,00) -6.88% $892,021.55 This is a cost change to the Contingency for RFI 154,dated 02/02/2023,to change doors 202&203 to Ambico ballistic hollow metal (HM)frames since the specified Insulgard HP500 ballistic door system required the doors to be outswing,which conflicted with the hallways. Ambico doors can accomodate an inswing to match the floor plan intent. 02/14/23 (870 00) -0.09%1 $891,151.55 This is a cost change to the Contingency for RFI 115,dated 12/05/22,to expand the chase in room219C and add chases in rooms 254& 251 for the vertical storm piping drops from the roof drains down to underneath the 1st floor slab. Nil MAN 02/14/23 (1,282,00) € -0.13% $889,869.55 This is a cost change to the Contingency for RFI 111,dated 10/03/22,for updates to A-132&A-133 clarifying quantity and locations of bathroom accessories. 02/14/23 (1,503,00) -0.16% $888,366.55Hill HIM This is a cost change to the Contingency for RFI 164,dated 02/14/2023,to increase the depth of the dumpster enclosure per revised sheets A-001 and'A-030 to meet the dumpster size and clearance requirements. Durnpster, enclosure CMU walls that have already been constructed will be removed,foundation will be extended to support the increased depth,and the CMU walls will be re- constructed. (10,495,00)CC( -1.10% $877,871.55 This is a credit change to the Contingency for RFI 173, dated 01/19/2023,to eliminate the Masterseal 581 waterproofing noted in the details for the dumpster enclosure.The dumpster enclosure walls will have a standard stucco finish. 02/14/23 1,581.00 € 0.17% $879,452.55 OWNER CONTROLLED OWNER CONTROLLED CONTINGENCY LEDGER This is a cost change to the Contingency for RFI 194 Stairwell doors hardware and fire rating changes to meet fire and FEMA 361,dated 03/20/2023,to change the door hardware specified for doors S102B and 5103 per manufacturer requirements in order for the doors to meet both a FEMA 361 rating and a 2hr fire rating. Separately,this RFI also updated all other stairwells doors from 1hr to 2hr and all glazing in these stairwell doors from 45min to 90min rating.There is no cost associated with these latter upgrades. 04/18/23 (5,875,00) -0.61% $819,533.55: This is a cost change to the Contingency related to Submittal 280537-1.2 to change the bi-directional antenna from a Yagi antenna(model#B©A-YDA763869-14-1)to a Westell panel antenna (model#CS03-777-999).This change was recommended by the BDA vendor,and reviewed and approved by Monroe County because the panel antenna is tested and rated for a lhigher wind MPH than the yagi antenna. 04/18/23 (1,582,00) 1 -0.17% $817,951.55 This is a cost change to the Contingency related to RFI 188, dated 03/06/2023,to demo part of the retaining wall just northwest of GL 9 to provide more turning radius availability for when trucks or equipment drive up the access ramp and need to turn left IPA 05/09/23 ( ,841.00) -0.40% $814,110.55 This is a cost change to the Contingency related to RFI'199, dated 05/09/2023,to extend multiple P1 and P9 walls to the underside of the roof deck(framing,iso,and drywall extended)that were originally called to terminate at the ceiling.This change enhances sound transfer reduction between corridors, building areas,and offices. 05/09/23 (80,114 CC( -8.38% $733,996.55 This is a cost change to the Contingency related to RFI 198, dated 04/11/2023,to add beacon lights on the top of the building per request from the Monroe County Building Department.This includes eight(8)FAA-approved beacon lights positioned at the building corners and along the roof perimeter. IPA 05/09/23 (18,634,00) -1.95% $715,362.55 OWNER CONTROLLED OWNER CONTROLLED OWNER CONTROLLED OWNER CONTROLLED OWNER CONTROLLED OWNER CONTROLLED OWNER CONTROLLED OWNER CONTROLLED OWNER CONTROLLED OWNER CONTROLLED OWNER CONTROLLED OWNER CONTROLLED OWNER CONTROLLED CONTINGENCY LEDGER