Loading...
23rd Change Order 05/02/2024 DocuSign Envelope ID:CB1 ED3F0-7AB0-4CSC-94B0-C9A254D63268 M.C.A.INSTR.8800.2 Enclosure(1) 3/28/2017 Page 3 MONROE COUNTY/DEPARTMENT OF AIRPORTS CONTRACT CHANGE ORDER PROJECTTITLE: KWIA Concourse A&Terminal Improvements CHANGE ORDER NO.: 023 INITIATION DATE: 12/22/2023 TO CONTRACTOR: NV2A/Gulf Keystar JV CONTRACT DATE: 8/17/2022 The Contract is changed as follows: The Original(Contract Sum)(Guaranteed Maxium Price) $ 101,461,771.00 Net change by previously authozied Change Order $ 9,201,047.74 The(Contract Sum)(Guaranteed Mxium Price)prior to this Chage order was $ 110,662,818.74 The(Contract Sum)(Guaranteed Mxium Price)will be by this Change Order $ 18,425.00 The new(Contract Sum)(Guaranteed Mxium Price) including this Change Order is $ 110,681,243.74 The Contract Time will be by TBD days The date of Substantial Completion as of the date of this Change Order is 3/9/2026 Detailed Description of change order and justification: Gary's Plumbing and Fire Protection is directed to proceed with the changes noted on the response to RFI#162 on a T&M basis to reroute the fire protection system in conflict with the future foundations for the passenger bridge and elevator. POTENTIAL CHANGE ORDERS IN THIS CHANGE ORDER: PCO# I Title Schedule Impact Amount 044 1 Fire Protection Systems Reroute in Existing Terminal TBD $ 18,425.00 Total: $ 18,425.00 This change order is 0.02%of the original contract price. Not valid until signed by Owner,Architect(if applicable),and ContractorFI 1 DocuSigned by: U V1S" , S, 6pct 4/26/2024 1 05:09:04 PDT ARCHITECT: DocuSigned by: DocuSigned by: DATE: CONTRACTORS: --� S�l L1t ��S� 4/19/2024 1 06:30:06 PDT DocuSigned by:827A75487... 8F59717D29E34A5... DATE: ocuS 4/30/2024 1 06:59:56 PDT EXECUTIVE DIRECTOR OF AIRPORTS 8E65F521`4C21`4D3... DATE:COUNTY/DEPUTY ADMINISTRATOR" � C, ? , . 05.01.2024 DATE: NFEOE COUNT TY ATTOPINEY a A� ROVE D S D S ,u eqPECK J..-ME6 A - ASE ST UNITY ATTORNEY Date 4LOZ24 DocuSign Envelope ID:CB1 ED3F0-7AB0-4CSC-94B0-C9A254D63268 NV K � GULF ST PCCO #023 NV2A/Gulf Keystar JV Project:20-2039-01 -KWIA Concourse A and Terminal Improvements 9100 South Dadeland Blvd,Suite 600 Program Miami, Florida 33156 3941 South Roosevelt Blvd. Phone:(786)233-5060 Key West, Florida 33040 Prime Contract Change Order #023: Gary's Plumbing-Fire Protection Sys. Reroute in Exist. Term. TO: Key West International Airport FROM: NV2A/Gulf Keystar JV 3491 South Roosevelt Boulevard 9100 South Dadeland Blvd,Suite 600 Key West, Florida 33040 Miami, Florida 33156 DATE CREATED: 4/02/2024 CREATED BY: Mansour Sodagari(NV2A/Gulf Keystar JV) CONTRACT STATUS: Approved REVISION: 0 DESIGNATED REVIEWER: REVIEWED BY: DUE DATE: REVIEW DATE: 04/02/2024 INVOICED DATE: PAID DATE: SCHEDULE IMPACT: EXECUTED: No REVISED SUBSTANTIAL SIGNED CHANGE ORDER 04/02/2024 COMPLETION DATE: RECEIVED DATE: CONTRACT FOR: 20-2039-01:Key West International Airport TOTAL AMOUNT: $18,425.00 Concourse A DESCRIPTION: Gary's Plumbing-Existing Fire Protection System in Conflict with Future Passenger Bridge and Future Elevator Gary's Plumbing and Fire Protection is directed to proceed with the changes noted on the response to RFI#162 on a T&M basis to reroute the fire protection system in conflict with the future foundations for the passenger bridge and elevator.The T&M ticket and cost breakdown are provided as attached. ATTACHMENTS: NV2A PCO#044($18,425.00 Garys Plumbing Fire Protect Sys Reroute).pdf POTENTIAL CHANGE ORDERS IN THIS CHANGE ORDER: PCO# I Title Schedule Impact Amount 044 1 Gary's Plumbing-Fire Protection Sys. Reroute in Exist.Term. $18,425.00 Total: $18,425.00 The original(Contract Sum) $101,461,771.00 Net change by previously authorized Change Orders $9,201,047.74 The contract sum prior to this Change Order was $110,662,813.74 The contract sum will be increased by this Change Order in the amount of $18,425.00 The new contract sum including this Change Order will be $110,681,243.74 The contract time will not be changed by this Change Order. IDS DS �fD R �� Christopher Kopec(McFarland Johnson, Key West International Airport NV2A/Gulf Keystar JV Inc.) 49 Court Street, Suite 240 3491 South Roosevelt Boulevard 9100 South Dadeland Blvd,Suite 600 Binghamton, New York 13901 Key West, Florida 33040 Miami, Florida 33156 DocuSigned by: DocuSigned by: DocuSigned by: DocuSigned by: (6sfbp�tr S. 6ptt "� SfVj&L4A � <- °w�..... ,.� �b S !1R'7F�FRd?23PIdE RFRSFS�Fd(:9Fdf12 0190938?7A75487... RF5Q7'17f11QF2d G5 SIGNATURE DATE SIGNATURE DATE SIGNATURE DATE 4/26/2024 1 05:09:04 PDT 4/30/2024 1 06:59:56 PDT 4/19/2024 1 06:30:06 PDT NV2A/Gulf Keystar JV Page 1 of 1 Printed On:4/2/2024 03:27 PM DocuSign Envelope ID:CB1 ED3F0-7AB0-4C8C-94B0-C9A254D63268 TM GULF BUILDING NV KEYST *_R NV2A/Gulf Keystar JV Project:20-2039-01 -KWIA Concourse A and Terminal Improvements 9100 South Dadeland Blvd,Suite 600 Program Miami,Florida 33156 3941 South Roosevelt Blvd. Phone:(786)233-5060 Key West, Florida 33040 Prime ntr c Potential Change Order #044: Gary's Plumbing-Fire Protection . Reroute in Exist. Term. TO: Key West International Airport FROM: NV2A/Gulf Keystar JV 3491 South Roosevelt Boulevard 9100 South Dadeland Blvd,Suite 600 Key West,Florida 33040 Miami,Florida 33156 PCO NUMBER/REVISION: 04410 CONTRACT 20-2039-01 -Key West International Airport Concourse A REQUEST RECEIVED FROM: CREATED BY: Mansour Sodagari(NV2A/Gulf Keystar JV) STATUS: Pending-In Review CREATED DATE: 12/18/2023 REFERENCE. PRIME CONTRACT None CHANGE ORDER: FIELD CHANGE: No LOCATION: ACCOUNTING METHOD: Amount Based SCHEDULE IMPACT: T N/A PAID IN FULL: No EXECUTED: No SIGNED CHANGE ORDER RECEIVED DATE: TOTAL AMOUNT: $18,425.00 POTENTIAL CHANGE ORDER TITLE:Gary's Plumbing-Fire Protection Sys.Reroute in Exist.Term. CHANGE REASON: Existing/Unforseen Condition POTENTIAL CHANGE ORDER DESCRIPTION: (The Contract Is Changed As Follows) ` Existing Fire Protection System in Conflict with Future Passenger Bridge and Future Elevator jGary's Plumbing and Fire Protection is directed to proceed with the changes noted on the response to RFI #162 on a TM basis to reroute the fire protection system in conflict with the future foundations for the passenger bridge and elevator. The T & M ticket and cost breakdown are provided as attached. ATTACHMENTS: I KWIA Terminal A Fire Line RelocatBon.pcSf , KWIA Wol;k 1cket.pdf, RFI#162 Existing Fire Protection System in Conflict with Future Passenger Bridge and Future Elevgtoi�pdf, i # Budget Code Description Amount 1 22-.00.10.10:S Plumbing.Subcontractor Existing Fire Protection System in Conflict with Future Passenger $16,750.00 Bridge and Future Elevator 2 99-.99.99.66.0 Procore OH&P.Other Prime Contract Markup $1,675.00 Grand Total: $18,425.00 it Christopher Kopec(McFarland Johnson, Key West International Airport NV2A/Gulf Keystar JV Inc.) 49 Court Street,Suite 240 3491 South Roosevelt Boulevard 9100 South Dadeland Blvd,Suite 600 Binghamton,New York 13901 Key West,Florida 33040 Miami, Florida 33156 Christopher Digitally 9 y p Di hall signed b Christopher K. Richard Strickland Kopec Date:2024.03.26 17:12:23-04'00' SIGNATURE DATE SIGNATURE DATE ,,,AGWUI DATE NV2A/Gulf Keystar JV Page 1 of 1 Printed On: 12/1812023 05:03 PM DocuSign Envelope ID:CB1 ED3F0-7AB0-4C8C-94B0-C9A254D63268 GULF BUILDING NV2A/Gulf Keystar JV Project: 20-2039-01 KWIA Concourse A and NV K = KE=-YST*R 9100 South Dadeland Blvd,Suite 600 Terminal Improvements Program Miami, Florida 33156 3941 South Roosevelt Blvd. P: (786)233-5060 Key West, Florida 33040 RFI #162: Existing Fire Protection System in Conflict with Future Passenger Bridge and Future Elevator Status Closed on 07/14/23 To Devin Shapley(McFarland Johnson,Inc.) From Alex Hyppolite(NV2A/Gulf Keystar JV) Michael Martin(McFarland Johnson,Inc.) 9100 South Dadeland Blvd,Suite 600 Frederick Mock(McFarland Johnson,Inc.) Miami, Florida 33156 Christopher Kopec(McFarland Johnson,Inc.) Date Initiated Jun 12,2023 Due Date Jun 19,2023 Location Project Stage Cost Impact Schedule Impact Spec Section Cost Code Drawing Number Reference Linked Drawings Received From Tim Marshall(Gary's Plumbing and Fire) Copies To Gustavo Lazaro(NV2A/Gulf Keystar JV),Jonathan Pena(NV2A/Gulf Keystar JV),Antonia Pinto(NV2A/Gulf Keystar JV), Mansour Sodagari(NV2A/Gulf Keystar JV) Activity Question Question from Alex Hyppolite NV2A/Gulf Keystar JV on Monday,Jun 12, 2023 at 10:00 AM EDT See attached proposed reroutes for the fire protection system in conflict with the future foundations for the passenger bridge and future elevator.Please review and advise if this is acceptable. Attachments FD111 D®FIRST FLOOR DEMOLITION PLAN-AREA D Rev,1 markup.pdf Official Response Response from Christopher Kopec McFarland Johnson,Inc.on Thursday,Jul 13, 2023 at 05:21 PM EDT Proceed with reroute of sprinkler piping main and branch piping to accommodate proposed elevator shaft wall. It is anticipated the 22"of clearance between FP main and proposed columns will be sufficient and rerouting won't be required in those areas. All Replies Response from Christopher Kopec McFarland Johnson,Inc.on Thursday,Jul 13, 2023 at 05:21 PM EDT Proceed with reroute of sprinkler piping main and branch piping to accommodate proposed elevator shaft wall. It is anticipated the 22"of clearance between FP main and proposed columns will be sufficient and rerouting won't be required in those areas. Response from Devin Shapley McFarland Johnson,Inc.on Monday,Jun 19, 2023 at 09:11 PM EDT Provide coordination drawings with formwork/structural shop drawings to definitively indicate conflicts with existing sprinkler piping. Design documents indicate approximately 22 inches of clearance between existing sprinkler piping and finished face of new structural column(s)and approximately 11 inches between elevator shaft wall and existing sprinkler piping. NV2A/Gulf Keystar JV Page 1 of 1 Printed On:Jul 14,2023 10:55 AM EDT DocuSign Envelope ID:CB1 ED3F0-7AB0-4C8C-94B0-C9A254D63268 State Plumbing License# State Fire Marshall License# C FC 1425735 FPC21-000111 µ, PROPOSAL Maly 31, 2023 NV2,A Group 9100 South Dadelamid B Blvd, Dalran One, Samite 600 Nfiaini.,P FL 33156 Attarm* Antonio lllinto Ref: 1 : 1 ,Cmwamcorse A,aiuji0' Teriu inal . emaaovatioum Sub: .Piiiui-e Sprinkler S st,em FIRE LINE RELOCA'TION ,.1"O t COMIC (11.:1NTE, NEVV C(:1161:UMN: Provide all la'lai r and material neccsswy to relocate 4" fire main approximately 4"tag time east aind tie back... into 2 '!/,P" r naira. PROPOSAL AMOUNT: S5,550.010 NEW ELUIVATOR FIRE LINE 11 11"a'1Lt: C "1111ON: Promriide all labor and nwleira.l necessary to relocate,4"' Riv spa®iirnik lcr main a!0proximiately l 51' to Ole vves,t amnmal tie hack intnm 4l" main line„ One amluari ht head shall be Iplugged and 2 pendant spmrinkleir heads shall Ilya! rell4:,aica"1't.ed to,r-naintain llma'o1ptrur sprit°mlk.ler coverage. 1`11101POS,41,ANIO N'r: S"!5,7501.0111 LANIO CAR ENTAL FIRE LINE I E1..At G4,"'101N: Provide all labor aril material necessary to relocate,V' l rle main a�ImlproXiirnatel 4°tcs tlmie North and 81 t;o time mvest. R.el cate 2 pendarft sp::mriralder hc!amis to amcxor ummmu:url,at.e new cod uivin for walking g bridge. f"ROPOS 1., I%41:;11.11 ''11l'. $5, 0.00 'A''ll woi k.to lase caanipleted during night dine System will be put on test, drained and taken eaat of !uerwnce for each prujea. /U coinclusion of wolirla, systemmn to be refilled and Pint:luck into siervice. e`a'pe° 'illy Saul°niitteal, G ("emmtiamn z;, President (J -y's Plaurnu ng and Fa"ire, Inc., 6409 2"d Terrace,Suite 1 * Key West,FL 33040 Phone(30 )296-6013 * Fax(30S)292-4978 * garysplumbingl@aol.com DocuSign Envelope ID:CB1 ED3F0-7AB0-4C8C-94B0-C9A254D63268 - I -� , ITT, A s 07 -L a 7.,,,-3 GA,w.�,_�.�.� .,,�.o � �.. i WORK ORDER NAME I �wE „ EL III ,,,,. .......................... w .. ., ,,,, „, CHARGE LSE I �, III„l � ,�„�, ��� � ,,,,,,,, ,,,,, �.,.e nimmmnnnnnnnu w�AUUUUU ..... .. .......... 1N�A'N@!Npuuu �a� rs§w... wwuxmmm�muuum nnuni T ITV s.,I.� 10 ........�� .�,.,.�,»-« ., „,.,. ,.�..�.�.�.�.�.�, ,��, ��. ,,,..a.... .�., . .., .., ,.��� .�.�..�� .W. ...� 1 99 ....................................... ... �.. ..,, m nro. .... �L low ,.„„. .,------. ,.,.,,,,,... ------------ �..--------------- ,�.,.».a, ,,,,,,, ................ „„„.........„.„.....„„„„.,....„„„„.......... ..mm...... ......................��,..,„„........„„„„. ,„„„... .......ww LlTotal Tax r L.