ORDINANCE NO. 234977
AN ORDINANCE AMENDING ORDINANCE NO. 15-1975,
THE SAME BEING AN ORDINANCE ENTITLED "AN
ORDINANCE PERTAINING TO MONROE COUNTY, FLORIDA,
ADOPTING THE NATIONAL ELECTRICAL CODE 1975 EDITION,
ETC. , " BY AMENDING SECTION 3 THEREOF TO ADOPT
A NEW SUPPLEMENT TO THE NATIONAL ELECTRICAL
CODE 1975 EDITION AND TO REPEAL THE SUPPLEMENT
ADOPTED IN 1975, SAID NEW SUPPLEMENT RELATING
TO APPLICATION FOR PERMIT PRIOR TO ELECTRICAL
WIRING, REQUIRING PERMITS, INSPECTION FEES,
INSPECTIONS; PRESCRIBING STANDARDS FOR PERSONS
ENGAGED IN ELECTRICAL WORK, PROVIDING PENALTIES
FOR VIOLATIONS, PRESCRIBING MINIMUM ELEVATIONS
FOR ELECTRICAL RECEPTACLES, AND PROVIDING
AN EFFECTIVE DATE.
BE IT ORDAINED BY THE BOARD OF COUNTY COMMISSIONERS
OF MONROE COUNTY, FLORIDA as follows:
Section 1. That Section 3 of Monroe County Ordinance No. 15-1975
be and the same is hereby amended to repeal the Supplement to the 1975 Edition of
the National Electrical Code adopted by said ordinance and to place in its stead
and hereby adopt the Supplement attached hereto and made a part of this Ordinance
entitled'1977 Monroe County Electrical Code Supplement."
Section 2. Violations of this Ordinance shall be prosecuted in a
County Court by the prosecuting attorney thereof, and upon conviction shall be
punished by a fine not less than $15. 00 nor to exceed $500. 00 or by imprisonment
in the county jail not to exceed 60 days or by both such fine and imprisonment.
Section 3. This Ordinance shall not apply to any municipality
located in Monroe County, Florida,
Section 4. All Special Laws, Ordinances, Resolutions, rules and
regulations in conflict herewith are hereby repealed to the extent of said conflict.
Section 5. This Ordinance shall take effect upon receipt of the
official acknowledgment from the Department of State acknowledging receipt of
certified copy of this Ordinance and that said Ordinance has been filed in said office
by the Department of Administration, Division of State Planning pursuant to the
requirements of Florida Statutes Section 380. 05 and Florida Statutes Chapter 120.
ApPROM dN -
PAGE
BOOK.---�
BOARD OF COUNTY COMMISSIONERS
OF MONROE COUNTY, FLORIDA
~
- ~'~-
Byl .~. - /z/l//)'~
v ~/. Cha(rman/Mayor .
L
ur:n~3Y CBlT!FY t~at this do_~t~~t;nt he,s
I n!t.m;, . I I 'ft"..",."" l',rt'
" .1 .l>^r C'~c\i 51., ...!L"','~ ."",,1
bf'cn re~I~WCu ,.., t!> J. ",1..
. t '" ... t""'t the same mee..s Wl..,J my
con en l. &riu i'<Il 9:J r.
approval. ~RlC"ARD ~!\~E .
" . '" .,.,..M
A5::;t 't,\t:\~n11.I.'".,~"
-2-
1977 MONROE COUNTY ELECTRICAL CODE SUPPLEMENT
;
,
t
:r
~
1. APPLICATION FOR PERMIT: Before any electrical wirinr, or
electrical apparatus or equipment for light, heat or pOller shall
be installed, within or attached to any building or structure
either public or private within the limits of the County a
written application for a permit to do so must be made to the
County BUILDING OFFICIAL. The application shall be accompanied
by a co~plete set of plans, specifications, "and schedule, as
may be necessary in the opinion of the County BUILDING OFFICIAL
to determine whether the installation as described will be in
con=ormity with the requirements of this regulation. Plans shall
be mechanically reproduced prints. Isometric or riser diagram
need not be to scale. The plans shall show the size of service
and feeder wires and conduit, the location of service switches
a..dcenters of distribution. The arrangement of circuits
snol~ing numbers of outlets and special purpose outlets and load
schedule for each panel shall also be shown. If it shall be
found by the C6unty BUILDING OFFICIAL that the installation as
desciibed will ingen.rkl' corif~rm with ~he.requirment~ of this
regulation and if ihe applicant has compl1ed with all the
provisions of thisCregulation, a permit for such installation
shall be issued by said County BUILDING OFFICIAL. The permit
when issued shall be for such installation as is described in
the application.
2. PERMITS: A permit will be required to do any electrical
construction of any character, install any electrical wiring)
apparatus or equipment) or make any extensions or changes to
existing system or wiring for light, heat or power, within the
limits of the County, excepting work done by employees of Public
Utility Companies, for said companies, and further excepting
the repairing of damaged apparatus or equipment a^d the ordinary
work necessary for the proper maintenance of same. No permit
will be required on service calls involving normal maintenance.
3. INSPECTION ,FEES: Before any permit is issued for the
ibstallation Or alteration of electrical wiring, device or
equipment, the person making application for such permit shall
pay to the County a fee in such amount as specified in
"Requirements and Schedule of Fees for Building Permits _
Nonroe County Building and Zoning Department".
4. INSPECTIONS: Any Electrical Contractor who "FREQUENTLY
FORGETS" to call for inspections or to take out permits for the
"SMALL" jobs shall be brought before the Licensing Board. If
work is concealed before ,inspection has been made and approved,
- 2-
...
.~
it
I
depending on circumstances, the Electrical Contractor will be
required to secure and present to the Electrical Inspector a
notarized letter from the Owner and General Contractor stating
they will accept the job without a rough-in electrical inspection
before proceeding with other work. It will also be noted on the
Certificate of Occupancy that no inspection was made. If the
Electrical Contractor is unable to secure letter, the laih,
plastering, paneling, etc....covering the electrical work shill
be removed and inspection made before continuing with job.
On any job requiring a permit) if the permit is not taken o~t
the fee will be doubled. Repeated violatioris of this or other
sections of this Code shall result in the Contractor being brought
before the Licensing Board to show cause why his License should
not be suspended or revoked.
5. SERVICE GROUNDING: The service grounding conductor shall
be run ~rom the meter or main switch enclosure to an approved driven
grounding electrode using an approved, exposed, accessible, ground
fittine making an electrical connection with the GROUNDING conductor.
From the same ground rod a number six (6) conductor must be bonded
to any metal water system in the building. See article 250-80
footnote of 1975 National Electric Code.
6. OWNER - BUILDING: Anyone, other than t~e owner, installing
wiring in an owner-builder permitted house shall be required to
have a Monroe County Certificate of Competency. An owner - building
is required to follow the National Electrical Code and the Monroe
County Electrical Code, which in some instances supercedes the
National Electrical Code, and to do the same quality of work that
the Electrical Contractor is required to do. If defects, omissions,
or violations exist on any part of the wiring system, approval will
be withheld until corrections have been made to comply to Code.
Where home owners are attempting to wire their own homes and three
(3) inspections have been turned down for violations or sloppy
\lork,' the Electrical Inspector may put a Stop Ivork Order on the
electrical portion of the job and require a Honroe County Licensed
Contractor to complete the job.
7. LICENSED .REQUIREMENTS: Except in the case of an owner doing
his Olin work, there~must be a licensed nonroe County Journeyman
Electrician on the job at all times any electrical work is being
done. The Journeyman must be employed by a tIaster Electrician -
Contractor. An Apprentice must have a Master or Journeyman present
at all times he is working.
8. DUTIES AND POWERS OF THE MONROE COUNTY INSPECTOR:
R. It shall be the duty of the County nUILDING OFFICIAL
11
~
-3-
~
I.
!1t
l~
'.
to issue permits for, and inspect all electrical wiring apparatus
or equipment for lights, heat or power inside of or attachedtb
buildings within the limits of ~lonroe County, and to look after
the enforcement of laws, rules and regulations, relating to same,
and to exercise a general supervision over all electrical
construction.
b. It shall be unlawful for any person, firm or
corporation to use any electrical current in or through any wiring
system until all inspections have been made and approved. Houses,
~ulilple units and other buildings whichre4uire a Certificate of
Occupancy must have all final inspections, which include air
conditioning duct and equipment, plumbing, electrical, building,
septic system, or sewer treatment plant and any other related
work which must be inspected, and approved. Upon approval of
inspections a Certificate of Occupancy will be issued and the
power company notified to connect the power. A TEMPORARY ELECTRICAL
CONNECTION \~ill be approved only after receipt and consideration by
t~e po0er company and the Electrical Inspector of a written and .
notarized statement from the owner giving reason why he requests
same before a Certificate of Occupancy is issued.
c. On all wiring installations where an increase or
decrease of load is to be made, the power company must be notified
before appliances or equipment are connected, so that proper
arrangements may be made by them.
d. When electrical wiring, apparatus or fixtures covered
by a permit shall be found on inspection by the County BUILDING
OFFICIAL to conform to the rules and regulations provided by this
regulation, the County BUILOrNG OFFICIAL shall issue a final
Certificate of Inspection certifying that the wiring, apparatus
or fixtures have been inspected and found to comply with the
terms of this regulation.
e. The County BUILDING OFFICIAL or any of his assistants
are hereby empowered to inspect or re-inspect all interior wires
and apparatus, conducting or using electric current for light,
heat or power, and when said condutors or apparatus are found to
be un~afe to life or property, he shall notify the person, firm
or corporation owning, using or operating them, or either of
them to place same in a safe and secure condition within twenty-
four (24) hours, or within such further time as the County BUILDING
OFFICIAL shall reasonably determine is necessary.
f. Whenever any wiring, apparatus or fixtures conducting
or using current for light, heat or power is found upon inspection
by the County BUILDING OFFICIAL to be immediately hazardous to life
or property, the said County BUILDING OFFICIAL or one of his duly
~~
-4-
authorized assistants shall immediately open the switch or ciF~uit
breaker controling the supply of current to such ,~iring, apparatus
or fixture, and shall post in a conspicuous place near such switches
or circuit breaker, a notice, as follows:
"NOTICE ----- WIRING CONDEHNEDIt. "THE USE OF
ELECTRICAL CURRENT IS PROHIBITED THROUGH THIS
WIRING OR EQUIPHENT UNTIL PROPER REPAIRS HAVE
BEEN MADE AND APPROVED BY "THE COUNTY BUILDING
OFFICIAL....REPAIRS MUST BE MADE AN~ THE
COUNTY BUILDING OFFICIAL HUST BE NOTIFIED".
After such notice is posted as provided in the foregoing, no person
shall close the switch or circuit breaker which has been opened by
the County BUILDING OFFICIAL or one of his duly authorized assistants,
nor use or attempt to use any current through such wiring apparatus
or fixtures which have been condemned, until necessary rc?airi have
been made and approved by the County B1JILDING OFFICIAL. T:",;) CouI)ty
BUILDING OFFICIAL may also notify the person, firm or corporation .
furnishing current to such wiring, apparatus or fixtures to
disconnect the supply wires and cut off the current from the premises
where such wiring, apparatus or fixtures are located.
IT SHALL BE UNLAWFUL FOR ANY PERSON, FIRM OR CORPORATION
TO HINDER OR INTERFERE WITH THE COUNTY BUILDING OFFICIAL, OR ANY
ASSISTANT IN THE DISCHARGE OF HIS DUTIES UNDER THIS REGULATION.
(Also see Article 90-4 enforcement in National Electric Code).
9. INSPECTION OF WORK: All Plumbing and other piping or tube
work and air conditioning duct work must be in place on work to be
concealed before the electrical wiring is inspected, and no such
wiring shall be considered as complete until all such plumbing or
piping is in place. Upon making an inspection of any electrical
wiring or equipment when same is found to have been installed in
satisfactory manner and in accordance with the provisions of this
regulation, the County BUILDING OFFICIAL shall place a notice at
the service switch or other suitable place stating that the
electrical work has been inspected and found to be_in accordance
with the rules as prescribed and the provision of this regulation.
It shall be unlawful to lath, seal or in any manner conceal any
electrical wiring or equipment until same has been inspected and
the notice posted as herewith required. It shall be unlawful to
cover or fill any switch or outlet box with plaster, cement or
other materials. When the electrical work in any building for
which a permit has been obtained is ready for inspection notice
shall be given to the County BUILDING OFFICIAL at his office,
stating the location of the work, name of the owner, and the
name of the electrician doing the work. As soon as possible
thereafter the County BUILDING OFFICIAL shall notify the
~ ""~''''~.";''':<'"''''-';''; ,.,,~,. <.l .... ,.~.__.,,....-...
-5-
electrician in charge of the work when he will inspect s~me and-
the County BUILDING OFFICIAL may test the work in the presence
of the electrician or in any manner necessary to demonstrate
that the work has been installed in a proper manner and in
accordance with the provisions of this regulation. After the
final completion of the work, a notice shall be given at the
office of the County BUILDING OFFICIAL for a final inspection,
and if the work has been property done, he shall issue a final
Cert,ificate. Said Certificate of Inspection is not to be
Temoven by any person other than the inspector. This Certificate
shall not relieve the electrician of responsibility for any
defective work which may have escaped the notice of the County
Inspector. Where a written electrical inspection is required by
a State, County or Federal Agency, the inspection shall be made
and the report signed by the Monroe County BUILDING OFFICIAL.
10. I PE~'\L.TY FOR VIOLATION: Any person violating or permitting
t 0 b e v i 0 1 .1 t e d any 0 f t 11 e pro v 1 s 1. 0 n s 0 f t his reg u 1 at i on s hall up on
conviction before the County Court, be punished by a fine of not
nore than FIVE HUNDRED ($500.00) DOLLARS, or by imprisonment in
the County Jail not exceeding SIXTY (60) DAYS, or both such fines
and imprisonment.
12. HISCELLANEOUS:
a. All kitchen receptacles for general use - shall be
limited to two (2) per circuit. Fixed appliances such as
refrigerator, dishwasher, disposal) trashnasher, freezer, etc.
shall be on separate ciruits.
b. Light outlets in clothes closets shall be installed on
the ceiling. Receptacles no higher than one (1) foot from the
floor will be permitted in clothes closets for the use of approved
mildew lights or heaters.
c. Branch circuits in all installations feeding all
outlets and switches shall not be smaller than nunber twelve
(12) copper wires.
d. Requirements in multiple dwellings: On new buildings
and rewired buildings, no branch circuits shall be connected to
serve more than (1) apartment. Distribution panels shall be
located in the ~partrnent they serve or in a public space. IN
RESIDENCES, PA~ELS SHALL NOT BE LOCATED IN CLOTHES CLOSETS,
BEDROOMS, UNDER STAIRS, KITCHEN CABINETS, OR ANY PLACE THAT IS
NOT. READILY ACCESSABLE.
e. Stairway lighting shall be controlled by three (3)
or four (4) way switches located at the top and bottom of the
l'.'f,.~'r;_.~"~~."'''''~-:"'. .~"".;.-. :~...-,_. ,', -iI' ...'- ".,..t:',"';':"y.,~?'{y,... .....,'.... ,. .<-;' ~.,.-.
-6-
stairways; except in multiple dwellings or apartments or other
public buildings where the stair lighting is controlled on
special hall, corridor or house circuits.
f. Every electrical contractor shall stencil or
provide a decal with the contractor's name and address and
phone number on the main switch or panel.
g. All service grounds must be enclosed in ~onduit with
thread hub type ground fitting with minimum number six (6) copper
Hire.
h. NO WATER PIPE OR FITTING shall be substituted f6r
electrical conduit and fitting.
i. Sub-feeds to mobile homes must be in conduit with
wire capacity of the main panel inside of trailer. Between
the bottom of the trailer and the ground where sub-feed comes
up, a short piece of WP Greenfield, approximately eighteen (18")
inches shall be installed.
j. All condutors must be copper (no copper clad aluminum
or aluminum) minimum number twelve (12), no aluminum conduit
underground, in slabs or within eighteen (18") inches of ground.
k. When electrical power is requested to a building
that is not completed far enough for a final inspection, the
General Contractor and the owner of the property must sign a
release before the power company is notified to connect the
building. Such service will be allowed only if all interior work
is finished.
1. Delete Note 8 to tables 210-16 through 310-19,
National Electric Code, (this deletion elimiates the de-rating
of allowable load current to allow increased nUMber of
conductors in a conduit).
m. All electrical conduits burried in concrete must
be PVC, schedule 40, and shall be tied in place.
n. Non-metallic sheathed cable (Romex) may be used in
wood frame construction only. Non-metallic sheathed cable will
not be used in masonry, concrete or steel frame construction.
o. No electrical equipment, electrical appliances,
circuits, switches and outlets shall be located or installed
below the 100 year flood level as defined in Monroe County
Ordinance Number 3-1975 except where the Building Department
shall determine that there is no practical manner in which to
l
-,
'~ ", ~:~""'~"-"'-::""'";"J,~,,,,,",,,,_:;~-:;.'t~";\~J..:Vi<,;'~~~:~':'~"::..','~-':''f,~f'';,~;~~~~:~'~';.'~'';-<4~~''''t:;''-:;<;'~,~".'' <., ,..",,_,t-,,<<....." ~',"" ",', ':., ;' ';-_.
~"'.~,'~.",.-"'?';F',,_"" ~"'"
-7-
... \o,
strictly adhere to this requir~nent and still use the area as
othen-rise alloHed. In such exceptional cases, the equipn'ent, .
appliances, circuits, switches and outlets shall be located an
installed to minimize the damage by flooding. It shall be
further required in such exceptional cases that the following
be adhered to:
1. All receptacles, switches, etc....shall
be located a minimum of four (4') feet
above any floor which is belo~ the flood
1 eve 1.
2. All circuits servicing receptacles, switches,
appliances, etc....below the flood level shall
be isolated on separate circuits from all
electrical installation above the flood level
and all such circuits shall include a
disconnect means in accordance with the above
Ordinance and this Code.
I
l
~
-8-
l3.
ELECTRICAL PERMIT FEES
1.
Minimum permit
f:ee. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . .
. . . . . . . .
. . $
10.00
2.
Outlets
General purpose (receptacles, switches, lights
telephone, T. V., alarms, etc.)..................$
.30
Special purpose (ranges, oven, refrigerators,
freezers, washers, dryers, dishwashers, space
heaters, water heaters, fans, signs, or any
fixed appliance).................................$
2.00
3. Air conditioning units:
Window or wall units.......................................$
3.00
Central system
flat fee for electrical hook-up...........$ 10.00
4. Services:
temporary construction service
100 amp and under..
100 amp to 200 amp..
200 amp to 300 amp.........~.................
300 amp.-1;o. 400. amp..................... ...
Over 400 combination of above fees........
flat
fee...
.....
......$
. . . . . . . . .'. $
. . . . . . . . . . . $
3.00
5.00
7.00
.....$ 10.00
.....$.15.00
......
. . . .
. . .
. . . .
. . . . .
'.'
. . . . .
Sub feeds to be
as services.....
\,
charged by amperes
at
the
same
rate
. . . . . . . .,. . . . .
5.
t.fotors:
,~
1 horsepower or 1 ess. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $ 3.00
1 horsepower to 5 horsepower...... . . . . . . . . . . . . . . . . . . . . . . $ 6.00
5 horsepower to 10 horsepower.. . . . . . . . . . . . . . . . . . . . . $ 12.00
10 horsepower to 25 horsepower.. . . . . . . . . . . . . . . . . . . . . . . . . $ 25.00
over 25 horsepower........ . . . . . ..... . . . . . . . . . . . . . . . . . . . . . . . $ 35.00
6. Elevators and escalators:
f 1 at fe e. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $ 35.00
.
~
__~.__'. ____ 'u...._ .__ ..._____. R..._.__._~._~_~....~__.,...._.....-._.....-_~._.,.._____
--.-.--.-,-,.- ---:. - - ~-- ,-- --.--.. _......-_..~--------~.,--_.- ~ .....~..
_.. .
I
J
-9-
7. Generators and transformers:
5 KW
5 KW
10 KW
Over
or
to
to
25
less...
10 KW..
25 KW.
KW . . . . .
. . . . . . . . . $ 5.00
. . . . . . . . . . . . . . . . $ 7.00
. . . ..... . . . . . . . . . . . .$ 10.00
. . . . . . . . $ 20.00
8. X-Ray machinges:
Flat fee................................................... $ 25.00
9. Welding machines:
25 amps (primary) or less... . . . . . . . . . . . ..$ 7.00
25 amps to 50 amps.. a . . . . . . . . . . $ 12.00
over 50 amp s. . . . . . . . . . . . . . . . . . .$ 15.00
10.
Signs:
fee for each sign connection...............................$
5.00
11.
Plug mold:
each 25 lineal foot or fractional part thereof...
....$
3.00
12.
Special purpose commerical outlets (music machinges,
coffee urns, popcorn machines, paint ovens, display
cases, etc.)
110
220
vol ts..
volts..
. . . . . . . .
. .
.$
..$
2.00
3.00
13.
Alterations
figured same as new work, per outlets, etc.
Hinimum
fee. .
.......
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . $
10.00
14.
Carnivals, circuses, road shows and similar temporary
installations:
minimum
fee.. .
. . . . ~ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.$
35.00
equipment grounds.
. . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . $
2.00
generators
per item number 7
r
)
,,',J '.,1,
I ~ '
1 :
NOTICE OF INTENTION TO CONSIDER
ADOPTION OF COUNTY ORDINANCE
NOTICE IS HEREBY GIVEN TO WHOM IT MAY CONCERN that at
first reading on Tuesday, November l5, 1977 at 1:00 o'clock p.m.
at the Monroe County Sub-Courthouse, Marathon, Florida and last
reading on Tuesday, November 22, 1977 at l:OO o'clock p.m. at the
Plantation Key Sheriff's Sub-Station, Plantation Key, Florida,
the Board of County Commissioners of Monroe County, Florida
intends to consider the adoption of the following County Ordinance:
ORDINANCE NO.
- 1977
AN ORDINANCE AMENDING ORDINANCE NO. l5 - 1975,
THE SAME BEING AN ORDINANCE ENTITLED "AN
ORDINANCE PERTAINING TO MONROE COUNTY, FLORIDA
ADOPTING THE NATIONAL ELECTRICAL CODE 1975 EDITION,
ETC., II BY AMENDING SECTION 3 THEREOF TO ADOPT A
NEW SUPPLEMENT TO THE NATIONAL ELECTRICAL CODE
1975 EDITION AND TO REPEAL THE SUPPLEMENT ADOPTED
IN 1975, SAID NEW SUPPLEMENT RELATING TO APPLICA-
TION FOR PERMIT PRIOR TO ELECTRICAL WIRING, REQUIRING
PERMITS, INSPECTION FEES, INSPECTIONS; PRESCRIBING
STANDARDS FOR PERSONS ENGAGED IN ELECTRICAL WORK,
PROVIDING PENALTIES FOR VIOLATIONS, PRESCRIBING
MINIMUM ELEVATIONS FOR ELECTRICAL RECEPTACLES, AND
PROVIDING AN EFFECTIVE DATE.
DATED at Key West, Florida this 20th day of October, A.D.
1977.
RALPH W. WHITE
Clerk of the Circuit Court of
Monroe County, Florida and ex
officio Clerk of the Board of
County Commissioners of Monroe
County, Florida
(SEAL)
.,3 111
~r!rrtart! af ~tatr
STATE OF" F"LORIDA
THE CAPITOL
TALLAHASSEE 32304
BRUCE A.SMATHERS
SECRETAFOY OF" STATE
MARY L. SINGLETON
Director. Division of Election,
904/488-7690
December 14, 1977
Honorable Ralph White
Clerk of the Circuit Court
Post Office Box 1680
Key West, Florida 33040
Dear Mr. White:
Pursuant to the provisions of Section 125, ()6 Florida Statutes, this will
acknowledge:
1./ 1 Receipt of your letter/s of Dece:nber 9 and ce~rtified copy /~es
1" of Monroe County Ordmance/s No/Nos. 7/-22 through /7-25
1. Receipt of an original/ls and certified copy lies of
Countv Ordinance /s No. /Nos.
1. Receipt of
Coun ty Ord inance /s re lati ve to:
1/ 2. We have filed this lthese ordinance /s in this office December 14
, 1977.
2. We have numbered this ordinance/s
fi led in this office
and was /were
lq~~
I.
,
.. . ~
("\: "
.\!~.:' "". !.\..<J.; d " "_
- ."L,.."j
Cord i a 11 y ,
~~.,~.
/;', ~" ,~ '"',
1,(~3':~> ~,,' - ",\,_.~"
(.t:_ ".' . i
t~, -: ,~.
~ . ?,
't_O,
.J
J....
-0--::--<-<-;" ~ ~ ':-<::5
~rs, ) N;fncy Kavanaugh "
(Chie~reau of Laws~
NKj