Loading...
Change Order No. KJ-010-016 C H A N G E 0 R D E R Project: KJ - NEW DETENTION FACILITY Change Order Number: 01-010-016 To Contractor: LAKE PLUMBING, INC. P.O. BOX 1294 EUSTIS, FL Change Order Date: 02/10/94 Architect's Project #: 32727 Contract For: PRIME PLUMBING Contract Date: 02/19/92 You are directed to make the following changes in this contract; all other provisions of the contract shall, except as specifically changed herein, remain in full force and effect. Issue: 097 - TRANSFORMER VAULT REVISIONS In accordance with the attached sketch and per the request of City Electric System(CES), supply and install the detailed oil containment tank and associated floor drain and piping for the main power transformer vault. --', ~ Contractor agrees to accept this LUMP SUM CHANGE ORDER as FINAL SETTLEMENT for this extra work and all ~~ted ~~cts due to this contract change for the LUMP SUM AMOUNT of $ 9,223.00 and 30 days. The Original Contract Amount was.................... .................. ............. ................. $ Net Change by Previously Authorized Change Orders .................................................... $ The Contract Amount prior to this Change was ......................................................... $ The Value of this Change Order is .................................................................... $ The New Contract Amount including this Change Order will be .......................................... $ The Contract Time wi II change by ..................................................................... The Date of Substantial Completion as of the Date of this Change Order is ............................ 1,394,753.00 -369,345.00 1,025,408.00 9,223.00 1,034,631.00 30 days 12/31/93 Recommended by Construction Manager: Approved by Architect: Morrison-Knudsen/Gerrits 5~C'tl~e~~ ~o ~{1/Y/' r Agreed to by Contractor: Authorized by Owner: Approved As T County Commissioners Date County Attorney's Office \- ~ "') ;.....7 / (II .A!J C '<> '1 t st: Danny L. Kolhage, Clerk By ~~.dIUt~~IA1) Depu Clerk Date_fY\ IVY (~ (}- 3 I I C1 q ~ By Not valid unless signed by the Owner, the Architect, and the Construction Manager. Signature of the Contractor indicates agreement herewith, including any and all adjustments in Contract Sum and/or Contract Time. MAIN TRANSFORMER VAULT OIL CONTAINMENT TANK TOP VIEW' 4. THREADED CONNECTION 2' CAPPED FOR OIL REMOVAL T 14' -L 30. 84' FRONT VIEW' 4. 60' o 2' CAPPED FOR OIL REMOVAL 7 30' ~ 30' 30' 84' BRACKETS VITH 112' EYE FOR VALL ATTACHMENT TYPICAL ALL CORNERS VELDED SEAMS 12 GAUGE GALVINIZED METAL \ BRACKETS VITH 1/2' $ FOR VALL ATTACHHE TYPICAL ALL CORNE VELDED SEAMS 12 GAUGE GAL VINIZED METAL NO T E: PLACE OIL CONTAINMENT TANK ON THREE (3) HOUSKEEPING PADS 16'X24'x6', SPACED 6' BETVEEN PADS, MAIN ELECTRIC VAULT 4' SCHEDULE 40 BLACK IRON THREADED TANK SALLY PORT PIPING FOR MAIN TRANSFORMER VAULT OIL CONTAINMENT TANK