Loading...
Change Order No. 31-001-008 C H A N G E 0 R D E R Project: NEW SHERIFF'S HEADQUARTERS BUILDING Change Order Number: 31-DD1-008 Change Order Date: 07/27/95 To Contractor: D. L. PORTER 1100 GILLESPIE AVE SARASOTA, FL Architect's Project #: 34236 Contract For: CONSTRUCTION Contract Date: 07/25/94 You are directed to make the following changes in this contract; all other provisions of the contract shall, except as specifically changed herein, remain in full force and effect. Issue: 055 - FINAL CHANGE ORDER In accordance with the A/E's instructions on Construction Change Directive #11 dated 6/2/95, revise the catch basin grate elevations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $ 578.90 In accordance with the A/E's instructions on Construction Change Directive #12 dated 6/14/95, revise duct in the Data/Tele Room and UPS Room. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$ 661.00 In accordance with the A/E's instructions on Construction Change Directive #13A dated 6/21/95, provide an opening in the existing concrete wall adjacent to the elevator shaft to accommodate a Time Capsule. . $ 195.00 In accordance with the A/E's response to DCR #170 dated 6/8/95, re-route the vent line for the jail fuel oi l tank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $ 243.00 In accordance with the A/E's response to DCR #155 dated 5/8/95, provide additional generator exhaust piping/lll.lffler insulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Provide (2) ADA approved signs for the elevators, indicating the stairs should be used in case of fire. Provide an elevator "on/off" key switch for the ground floor call button. . . . . . . . . . . . . . . . In accordance with the A/E's response to DCR #178 dated 7/12/95, provide wax-coated sprinkler heads in the parking area under the building in lieu of the specified standard upright. . . . . . . . . . . . . . $ 311.00 In accordance with the A/E's response to DCR #168A dated 7/6/95, add one light in elevator pit. . .. .$ 221.00 In accordance with the Architect's response to DCR #174 dated 7/6/95, provide (2) lighting contactors for the timer tie-in of the ground floor covered parking lights. . . . . . . . . . . . . . . . . . . Credit for ground floor precast insert holes . . . . . . . . . . . . . . . . . . . . . . . . . . . Decrease the base bid estimated qty of augercast concrete piles from the specified 2,400 lf to the actual qty installed of 2,329.6 If. <70.4> lf at the bid price of $30.00/lf equals a decrease of. .$1,210.00 .$ 92.00 .$ 192.00 .$ 693.00 .<$ 700.00> .<$2,112.DO> Contractor agrees to accept this LUMP SUM CHANGE ORDER as FINAL SETTLEMENT for this extra work and all related impacts due to this contract change for the LUMP SUM AMOUNT of $ 1,584.90 and 0 days. The Original Contract Amount was ...... .................... .............. ............................ $ Net Change by Previously Authorized Change Orders .................................................... $ The Contract Amount prior to this Change was ......................................................... $ The Va l ue of th i s Change Order is.................................................................... $ The New Contract Amount including this Change Order will be .......................................... $ The Contract Time wi II change by ..................................................................... The Date of Substantial Completion as of the Date of this Change Order is .,....................,..... 3,514,000.00 -43,575.00 3,470,425.00 1,584.90 3,472,009.90 o days 08/13/95 Recommended by Construction Manager: Approved by Architect: GONZALEZ ARCHITECTS 130 NORTHS~D~ Y WEST, !LI' 33040 ,. .. -" 7~21-'1S Date ~.:C Agreed to by Coritractor: D. L. PORTER 1100 GILLESPIE AVE SARASOTA~ FL 34236~ k~~ . By Da??l/~ ized by Owne r : -< ' "'tI!--n '- .. C Monroe County Board ot:tounty c~sion~ 500 Whiteh d Street:-- -::Ct. '.:J Key West, 3304 ..;..~ By Mayor/Chairman Date 'ciency: Attest: Danny L. Kolhage, Clerk By-.te.... ~~~~~.. ~ De Cler B Date Date Not valid unless signed by the Owner, the Architect, and the Construction Manager. Signature of the Contractor indicates agreement herewith, including any and all adjustments in Contract Sum and/or Contract Time.